Question about Generac 5622 GP Series GP5000 6,250 Watt 389cc OHV Portable Gas Powered Generator

Open Question

I have a GENERAC 5000 WATT generator with a new engine and generator.The engine runs,but the generator produces no electricity.

Posted by on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

mamicheddy
  • 79 Answers

SOURCE: no power output from my generac 5000 power plus

It is possible that your voltage regulator is shot but before purchasing the volt regulator try flashing the fields first and make sure the brushes and rings are clean.

Posted on May 12, 2009

  • 26 Answers

SOURCE: how do i flash my generac 5000 power plus generator

its the rotor ,the stater ,voltage regulateor or control board. i fix these everyday. it also just be the brushes.

Posted on Jul 14, 2009

  • 10 Answers

SOURCE: I have a 17kw generac generator that will run

I have the 18KW model and was told that most alarms relate to a low battery. Make sure the battery charger in the Transfer Switch is properly feeding the battery or hook up a mobil battery charger to the battery and see if the alarm goes away. Good Luck.

Posted on Oct 12, 2009

kel1guy2002
  • 3740 Answers

SOURCE: Need a Repair Manual for

This manual should have what you need:

http://lawnandgarden.manualsonline.com/manuals/mfg/generac/86640.html

Click the link: The click on the image then wait for popup window... Close popup window click on get this manual.

It is published by Generac

Thanks for choosing FixYa

Kely

Posted on Sep 18, 2010

  • 2422 Answers

SOURCE: can i use my welder

probably but it may be a streck 1300 watts may do it but it depends on the draw of the welder and it will be maxed out thats 13 100 watt light bulbs running at the same time use common sence

Posted on Nov 29, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    Generac troubleshooting my generac 14kw generator engine runs why doesn*t it produce electricity


    Assuming the generator circuit breaker is on, depending on the model it could be the voltage regulator or the slip ring brushes or both. If it's a portable it could be a capacitor problem.

    Jul 02, 2014 | Electrical Supplies

    1 Answer

    I have a Generac 6500E. The electric start turns over the engine but will not start. Pull start works fine


    If the pull start works, but the electric start doesn't try the following. Either give the battery on the generator a full charge, and if after a full charge it doesn't start, get a new battery.

    Jan 20, 2013 | Generac GP6500E - 6500 Watt Electric Start...

    1 Answer

    My Generac GP5000 generator runs great for about 4 minutes until it heats up then it starts cutting out and backfiring until it ultimately dies and wont restart until it cools down. the generator has...


    If it is new and under warranty, talk to Generac about getting it fixed.

    If it is old and unused, it probably needs fuel system cleaned out. Carb needs to be removed and cleaned inside and out, fuel lines need flushing, filter changed and if it has an automatic choke, it needs to be checked because it sounds like it is stuck on.

    Oct 03, 2012 | Generac 5622R GP5000 GP Series 5000 Watt...

    1 Answer

    Can i use my welder with my generac 5000 generator? my welder is 220VAC.


    probably but it may be a streck 1300 watts may do it but it depends on the draw of the welder and it will be maxed out thats 13 100 watt light bulbs running at the same time use common sence

    Nov 29, 2010 | Generac 13,000 Watt / 13,000 Watt Home...

    4 Answers

    How do i flash my generac 5000 power plus generator


    well I have a special flasher unit but I believe you can put 12 volts to the brushes while it's running. That should do it.

    Apr 09, 2009 | Generac 13,000 Watt / 13,000 Watt Home...

    1 Answer

    No power output from my generac 5000 power plus.


    sounds like you need to "flash the field". This means you've lost you excitation voltage for the generator to produce electricity. In most cases you need to get a 9volt battery and connect it to 2 & 6 inside the generator. They are Blue & Red wires, but they are not the only blue & red ones there. The generator should be running and the battery should only be connected for about 5 seconds. This is very dangerous because of all the high voltage and democrats.

    Apr 09, 2009 | Generac 100 Amp 120/240-Volt Transfer...

    Not finding what you are looking for?
    Generac 5622 GP Series GP5000 6,250 Watt 389cc OHV Portable Gas Powered Generator  Logo

    Related Topics:

    62 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Generac Electrical Supplies Experts

     Kenneth
    Kenneth

    Level 2 Expert

    50 Answers

    Ottoniel

    Level 2 Expert

    202 Answers

    JOHN LAPIER

    Level 3 Expert

    2422 Answers

    Are you a Generac Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...