Question about Samsung AS18A6RB Air Conditioner

2 Answers

I have samsung wall type split,working normally for some time then make a small beep indoor unit then the compressor turns off..

Posted by on

Ad

2 Answers

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 38 Answers

Check thermisters

Posted on Sep 02, 2010

  • Noor Mulla
    Noor Mulla Sep 02, 2010

    change the thermister

×

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Samsung Master
  • 43,501 Answers

Hi,
The unit is locking out...find out where to check the "code" that tells why... usually on the outdoor unit circuit board...

heatman101

Posted on Aug 28, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have samsung split ac 1.5 ton 2.5 years old when am switch on the ac the indoor unit is working when it tires to on the out door unit after 3 minute delay suddenly the ac is restarting but the out d


Make sure all of the pressure switches are closed on the low voltage control circuit on the outdoor unit. If any are stuck open, the compressor will not kick on. Or just push the compressor contactor in with an insulated screwdriver to ensure the compressor does actually work.

Dec 28, 2014 | Samsung Heating & Cooling

Tip

Ductless Split Air Conditioner Review


Ductless split air conditioning units are the very best thing for some situations. Of course they can be installed in the place of most any central air conditioning unit. They also are a very good alternative to window air conditioning units. I will explore the use of these units more closely and look at how they can be used effectively.
One of the many problems encountered by the professional is when they are asked to install central air conditioning in an older home that was never designed with air conditioning as even a possibility. The walls may be very thick stone. Often they have very little or no insulation. The floor structures may be rough cut lumber. The joists spacing may be random. Walls and ceilings are plaster and lathe. Basically everything is stacked against any type of ducted central air conditioning. Many log style homes also are not very easy to get any kind of ducted central air conditioning installed. The open ceilings and the bare log wall design does not allow for any kind of ducting. I'm sure there are other situations. These are the ones that I have come across most frequently.
If you have a home or building that falls into one of these categories you may want to investigate installing a ductless air conditioner. This type of air conditioner can be installed in almost any home or building. The small indoor unit can be attached to the wall with a few screws. Most of the units only require that a three inch hole be bored through the outside wall. In new installations the units can be placed on inside walls with some fore thought and planning. For installation in older homes or homes that are already built you will want to plan the units to be on the outside walls.
The outdoor condenser units can be placed up to one hundred feet away from the indoor units. One outdoor unit can be used for many indoor units. Up to four indoor units can be attached to the same outdoor condenser. Some very advanced electronics will control the operation of the condenser and compressor to supply the refrigerant to the indoor air handler units that are running at the time. With variable speed technology the compressor and the condenser fan will only run as fast as needed. This technology has become very efficient in the last few years. You do not have to give up any efficiency with these ductless split units.
Another advantage to these mini split air conditioners is that they can be controlled to run only in the rooms that you actually need air conditioning in. If you are not going to be in a room you can shut down the unit. The units also have timers that can be set to turn the air conditioning on or off at preset times. If you are not going to be home all day the air conditioning can be setback or turned off. The timer will turn on the air conditioning so that you return to a cool house. Central air conditioning is very hard to zone effectively. Also with large central air conditioning systems the outdoor compressor will be running at full capacity even though only a few rooms amy be calling for cooling. There are some central air conditioning systems that are do some staging and variable speed technology. These are not as efficient or as effective as the ductless split technology.
Ductless split heatpumps are another great idea to look at. For a few dollars more you can also very easily have heat from your air conditioning mini split. Then especially in the mild spring and fall weather you can have some very efficient heat with out starting up that big monster of a furnace or boiler in the basement. In southern climates the heatpump version of the ductless split system may provide enough heat year around.
Ductless split air conditioning is definitely something that can solve many problems for some homeowners. Add to that the many advantages of these units and you will find that they are worth every penny that you will invest into them. As with any project like this make sure that you screen your contractor. These units are not for do it yourself people. There are many things that need to be done correctly for these units to work properly and efficiently. A refrigeration license is also required to install these air conditioners.
By doing a little research and hiring the right person you will enjoy many years of trouble free service from your new ductless mini split system.

on Dec 04, 2009 | Heating & Cooling

1 Answer

F6 error code on Frigidaire split unit ac, model FSC12CM6J/FSE12CM6J. Solution says to check fuse? Where is this located?


It seems like the indoor fan is not running. Quite a few split systems have a fuse on the indoor board. It will require stripping off the outer cover of the indoor unit and removal of the electronic box cover. The indoor board is in there. The fuse may be replaceable or it may be a type that is soldered on which makes it virtually non replaceable. ( A new indoor board will be required) Make sure all power is turned off or disconnected before you do anything. Another possibility is the fan motor start capacitor has failed. Try this first before stripping the unit. When the unit is turned on and the outdoor unit has started, give the indoor fan barrel a flick with your finger to start it spinning, if it keeps spinning and the error doesn't appear, it would indicate that the fan motor start capacitor has failed. The capacitors on indoor units are normally small black square boxes with 2 terminals on it. These capacitors are mounted inside or close to where the indoor electronic box is. Again, make sure all power is disconnected or turned off at the meter box before you do any disassembly.

Apr 09, 2014 | Frigidaire Heating & Cooling

1 Answer

Samsung 2.0TR split ac compressor getting heated up and tripped after running for 10 mins


High limit switch set to high, obstruction in the system, or your compressor may be wearing out.

Apr 12, 2013 | Heating & Cooling

1 Answer

Hi, I have a goldStar GA 1866VHR split Airconditioner, (5050w cooling and 5040w heating capacity). Today I noticed that compressor/condenser unit was still running after I turned off the aircond: from the...


Thanks for your detailed information. But solution is very simple. The compressor contactor in out door unit. Struck. And hence, when you power on, without indoor commanding, the out door starts running.

Replace same type Contactor relay (In out door unit) immediately. Hope, it's helpful.

Jan 19, 2011 | Heating & Cooling

1 Answer

LG Art Cool, 2 splits. Error code CH7


Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear.
Splits = Compressor Over Current (CT2)

Jul 09, 2010 | LG Art Cool LA121CNP wall/window Air...

2 Answers

York Mini-Split Not Cooling? : (


This can only be a gas problem.
the split units goes on on and off if a shortage of gas is involved, the chances that you would here it wont be that big for the fans would make too much noise.
get a repair man for a re gas and all is well.

Good luck.

Wouter.

Oct 21, 2008 | Sanyo 09KS51 Mini Split Air Conditioner

Not finding what you are looking for?
Samsung AS18A6RB Air Conditioner Logo

Related Topics:

288 people viewed this question

Ask a Question

Usually answered in minutes!

Top Samsung Heating & Cooling Experts

billconfused

Level 2 Expert

211 Answers

Ezewudo Onyekachi
Ezewudo Onyekachi

Level 3 Expert

406 Answers

yadayada
yadayada

Level 3 Expert

76109 Answers

Are you a Samsung Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...