Question about Konica Minolta bizhub 350 All-In-One Laser Printer

1 Answer

Need a reset code

I purchased a new image transfer roller and ozone filter because the machine was telling me that they needed replaced. Popping them in was no biggy. Trouble is, the printer doesn't seem to know they've been replaced. I'm betting on a reset code, but I can't find anything in the five user manuals the salesman provided us. Can you help?

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Champion:

    An expert who has answered 200 questions.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

  • Expert
  • 214 Answers

Hey.
You have to go to service menu ---> stop -> 0 -> 0 -> stop -> 0 -> 1 ---- and choose counter -> maintance/parts counter find these parts on the list, make them blue/touch them and touch C.
then exit to normal mode

good luck

Posted on May 11, 2008

  • Illar Lumiste May 11, 2008

    forget, chooce utility - and details from left side and then stop-0-0-stop-0-1

×

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fuser unit


can you explain more the functions of each are as followed fuser melts the toner to the paper so it dosnt rub off ozone filter filters out the ozone so you don't get headaches and turn al the rollers to bubble gum transfer roller pushes the paper onto the transfer belt applying the image to the paper and imagine unit is where thetransfer belt gets the image from

Aug 16, 2014 | Konica Minolta bizhub Printers & Copiers

1 Answer

I have a Konica Minolta bizhub C351 that has an error message " transfer roller unit needs to be replaced soon" I purchased and replaced the "image transfer roller unit 4049-411 that also has the nu


Enter in the service mode:
Press Utility key - Meter count - Details - Counter mode - select present parts life and reset(clear) the transfer roller counter.

Mar 25, 2013 | Konica Minolta bizhub Printers & Copiers

1 Answer

Where do I find the Paper Dust Remover/Ozone Filter and the Transfer Roller Unit?


I believe the filter is located on the right or left side. The "Transfer Roller Unit" is the foam roller inside the right door.

Apr 07, 2010 | Konica Minolta bizhub C351 All-In-One...

1 Answer

I have a Konica Minolta Bizhub C350 which is now indicating that it needs to have the image transfer roller unite and paper dust/ozone filter replaced. Where are these located in the machine and is it...


I would advise having a copier technician replace those items it is not that hard to do but if you dont get the roller seated in the holder properly it can destroy the transfer belt and that could get expensive

Nov 29, 2009 | Konica Minolta bizhub 350 All-In-One Laser...

1 Answer

Bizhub C450: After replacing the image transfer roller & ozone


In Service Mode -> Counter -> Life -> Select the one you want to reset and press 'C'

May 21, 2009 | Konica Minolta bizhub C450P Laser Printer

1 Answer

Reseting counter after installing new image transfer roller unit


You need to go into tech rep mode to reset.
press: stop 0 0 stop 0 1, then 0 0 0 0 0 0 0 0, press enter, then press counter on the left, select life, then highlight image trans roller and press the C button, repeat for paper dust remover and exit tech rep mode

Jan 17, 2009 | Konica Minolta bizhub 350 All-In-One Laser...

2 Answers

Konica Minolta Bizhub c351


you have to clear the counters in tech rep mode.
Utility - counter - details- then the following sequence....

stop-0-0-stop-0-1 then press counter - life - then highlight the parts you changed and press the C button, then exit .

Jul 23, 2008 | Konica Minolta bizhub C351 All-In-One...

2 Answers

Need to know how to reset codes


To reset the life counters for the transfer roller & ozone filter you will need to enter the service mode.

To do this press utilty, meter count,details(if available), then stop, 0, 0, stop , 0, 1.
You should now be in tech rep mode, select counters then life.
Select the transfer roller/ozone filter button and press the C key on the keypad.
It should zero the life count.
Now press end, exit etc until you back at the copy screen.

Warning: Please do not reset or clear any other data within tech rep mode or you may inadvertantly affect the performance of you machine.

Hope this Helps.

May 05, 2008 | Konica Minolta bizhub 350 All-In-One Laser...

1 Answer

Consumable replacement message


You need to go into service mode to reset these parts. Start by hitting the "Utility" button on the control panel. Then select "Meter Count" from the menu. Next hit "Details". Then you need to hit the following buttons in this order, STOP,0,0,STOP,0,1. This will bring you into the service mode on this machine. From there you should select "Counter". From the Counter menu select "Special parts counter". Highlight the parts you replaced and hit the "C" on the control panel to clear the counter. This process should be done for any parts that you replace and will prevent the message from popping up.

May 11, 2007 | Konica Minolta bizhub 350 All-In-One Laser...

Not finding what you are looking for?
Konica Minolta bizhub 350 All-In-One Laser Printer Logo

294 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Printers & Copiers Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

5695 Answers

David Burkhart
David Burkhart

Level 2 Expert

207 Answers

George Mclaughlin

Level 2 Expert

330 Answers

Are you a Konica Minolta Printer and Copier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...