I bought a house with a Night Sentry Solid State Timer model # EJ341 and have no instructions on setting or programming the unit.

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 2 Answers

Rapid Programming.
1. Move control lever to OFFCLEAR for at least 5 seconds
• red indicator light goes off
• all time settings are
erased.
2. Move control lever to ON.
• red indicator light will start
flashing.
3. Check a clock; then turn pushbutton time dial clockwise at least one click.
• stop at the half hour nearest to present time (note
AM or PM).
Note: When turning pushbutton time dial, do NOT
accidentally PRESS at the same time.
4. Press pushbutton time dial once to enter present time.
• red indicator light goes off (present time has been
recorded).
5. Turn pushbutton time dial clockwise to desired
ON time.
• red indicator light blinks with each click.
6. Press pushbutton to enter ON time.
• controlled light(s) will turn on.
7. Turn pushbutton time dial clockwise to desired
OFF time.
• red indicator light blinks with each click.
8. Press pushbutton time dial to enter OFF time.
• controlled light(s) turn off.
9. Repeat 5-8 for other on/off times.
10.Turn pushbutton time dial for at least 2 more turns
from the first ON time to complete this program
• red indicator light will turn on and stay on (steady
light means timer is in automatic).
Note: Pushbutton time dial does not turn
automatically after setting to indicate time of day

Posted on Dec 05, 2012

EJ351 manual

This timer is sometimes called Night Sentry

Posted on Oct 07, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have the EJ351 mechanical in-wall timer for my outdoor garage lights which are LED.I set the timer but lights go on way early Is there another method for programming the switch that I could try.


This is not a mechanical timer; it has a solid-state switch. It is designed for incandescent lights, and is not recommended for CFL or LED lamps. It may work properly with dimmable LED lights if you have at least four (total 32 Watts or more) connected.

You can try programming using the 24-hour method described at the top of page 2 of the manual. I've provided the link to the manual below.

https://www.intermatic.com/-/media/inriver/6842-8228.ashx/EJ351-Instructions-EN

Jul 08, 2017 | Hardware & Accessories

1 Answer

Timer programs disappear on my Brinks Digital Timer 44-1041. I believe home power failures are the cause but I'm not sure.


Look at electrical rating of timer to make sure it matches the air conditioner.
Often an air conditioner is too heavy a load for ordinary programmable timer... even if timer is rated for inductive load,,, because motor pulls a lot of initial amps that eventually overheat timers.

-Suggest buying another or the same timer, and using intermediate relay ... like a solid state relay... or miniature relay... and so the timer turns on the relay, and the relay handles the high amp switching ... and this means the timer lasts longer
http://waterheatertimer.org/H230A.html#solid


-Or buy 17 program CN series timer, and use relay or contactor
http://waterheatertimer.org/Programmable.html#PB

-Or buy several of the Brinks timers and replace when they go bad.

-Also consider surge protection... because simple power outage will blow out electronic circuit boards. Check household grounding also.
http://waterheatertimer.org/How-to-wire-Whole-house-surge-protector.html

Gene
Water Heater Timers Save Money

Jul 06, 2015 | Hardware & Accessories

1 Answer

Night sentry-solid state timer model ej341-70


Copy following links for EJ341 timer manual:
http://waterheatertimer.org/pdf/EJ341-manual.pdf
http://waterheatertimer.org/Intermatic-timers-and-manuals.html

May 27, 2012 | Solar Intermatic Single Pole Model Ej341c...

1 Answer

Dear Sirs, I try to change Intermatic E1343 solid state timer to normal 2 ways switch. I saw the cable in 3 colors : black, red and blue. do ou know the menaing of each cables? if you can email me...


I think you mean Ei343 instead of E1343.
I have manual for EJ341 and EJ343 that shows wiring for single-pole and 3-way.
I believe the EJ343 is wired same as Ei343 since Intermatic Load rating chart groups these timers together.
http://waterheatertimer.org/pdf/Intermatic-EJ343-timer.pdf

Load-rating chart:
http://waterheatertimer.org/pdf/Load-ratings-for-Intermatic.pdf
Load chart implies this is 120Volt in-wall timer for inductive and tungsten loads up to 400Watts.

Now here's something to remember.
When any timer is wired for 3-way, the timer replaces one of the 3-way switches.
The other 3-way switch remains, but the other 3-way switch has to be rewired differently so that 3-way timer works correctly.
When removing timer from 3-way circuit, don't forget to re-wire the remaining 3-way switch so it works correctly.

To convert your timer to operate single-pole: Timer Black wire connects to Hot wire from circuit breaker. Timer Blue wire connects to wire going to Light. Red wire is capped off.

To see similar wiring illustrations for newer generation Intermatic timer, open following link:
http://waterheatertimer.org/ST01C-program.html#ST01C

Aug 01, 2011 | Garden

2 Answers

Where can i buy a intermatice ej341? we live in delray beach, florida


1) I searched Intermatic for EJ341 and showed no result:
http://www.intermaticstore.com/

2) I searched internet for EJ341 and showed a guy replacing EJ341 with GE 15086
http://www.fixya.com/support/t6267843-am_replacing_old_intermatic_model_ej341

3) Intermatic makes timer with similar number: EJ351 push-button-dial-type timer, which is available with internet search
http://www.intermatic.com/products/timers/consumer%20indoor%20timers/in-wall%20timers.aspx

4) You can choose from many timers on market today:
http://waterheatertimer.org/Programmable.html
http://waterheatertimer.org/Countdown.html
http://waterheatertimer.org/Woods-timers-and-manuals.html
http://waterheatertimer.org/GE-timers-and-manuals.html
http://waterheatertimer.org/UPM-timers-and-manuals.html

5) Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jan 22, 2011 | Solar Intermatic Single Pole Model Ej341c...

2 Answers

Can i get online instructions on how to program my


moved into house with 4 station Orbit sprinkler unit. Manual is faded, cannot figure out how to get it to control the sprinkler system. Can I get online instructions on how to program it?

Jul 22, 2010 | MicroBoards Orbit (ORB-4201-01) Burner

1 Answer

Bought yesterday. Following instructions,0000 is not the default code on this unit!!


Try this:
Trail Scout and Trail Sentry camera re-programming procedure.
1) Turn unit on and wait for screen to prompt password
2) Press the enter button and hold until camera switches into 5-digit password mode _ _ _ _ _.
Trail sentry cameras will not indicate 5-digit mode on the screen, but will indicate _ _ _ _ instead of HHHH .
3) Press enter to confirm 5 digit mode (for trail scouts go to next procedure).
4) Enter 5-digit code 66214 and press enter button( trail sentry cameras will accept a 5th Digit after the 4th 0ne is entered in the _ _ _ _ screen.
5) Camera will now go into operating mode, and user can now program a new password from the setup mode

Oct 04, 2009 | Bushnell Trail Sentry 11-9200 Digital...

2 Answers

Need instructions


I have a similar sounding timer. It has the same dial and an AM/PM window on it and is made by Dynascan. I found this post on Fixya: http://www.fixya.com/support/t2314418-instructions_program_intermatic_ej351c and then went to the intermatic site and got these instructions: http://www.intermatic.com/~/media/files/intermatic/products/instructions/timers/ej351c%20-%20english.ashx I used the RAPID programming instructions and they seemed to work great (at least the red light acted like it was supposed to.) Guess I'll find out tonight :)

Dec 01, 2008 | Hardware & Accessories

Not finding what you are looking for?
Hardware & Accessories Logo

Related Topics:

862 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5089 Answers

Hippy_dd

Level 2 Expert

110 Answers

Brad Brown

Level 3 Expert

15441 Answers

Are you a Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...