Question about Goodman CLQ36AR49 Air Conditioner

1 Answer

The model # is CKL36-1L. The circuit breaker for the unit flipped twice last week. Yesterday I noticed the blower in the house was working non-stop, but the conditioner was not working. The fuses were checked and there appears to be continuity. How do I find the problem?

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 3 Answers

Your compressor may be going bad. Check and make sure you have a proper sized breaker/fuses for the unit. Check and see that the capacitor is big enough to start the compressor and is not blown. I think those take a 45-5 cap. If all else fails, get a hard start kit from an HVAC distributor and install it as per the instructions. It may help delay the inevitable if the compressor is going.

Posted on Aug 28, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Outside A/C unit not working


is this 3 phase? 3 phase is diffrent from single phase

Jun 18, 2013 | Goodman CLQ36AR49 Air Conditioner

1 Answer

My Sunbeam air conditioner has always flipped the breakers in my house (old wiring), but it worked fine for two summers and then sat last summer. This summer it blows the breaker constantly and in the...


This is a good question to ask. 1. if a unit trippes a breaker its for 2 reasons. A. to protect the wiring from catching fire . B. to protect you from electrical contact with ashort condition. Before you buy a new unit I would recommend you fix the wiring as bad siring is ******* the unit and costly to operate due to load resistance. Also replace any breakers that are unsed to support this unit. Brealers go bad esp if they have been problematic in the past. I am not certain as to the size of the unit you have now but if it cooled the room well then replace it with a match or a bit bigger unit.
As to why it tripps the breaker now? could be a couple thing Bad wiring like you state. weak breakers as I pointed out. or a bad compressor or fans. Or in my view its most like a combo of all the above. Hope this helps let me know.. Jon

Aug 03, 2011 | Kenmore 76129 Air Conditioner

1 Answer

Inside Electric Furnace/Air Handler Not Working. Please help!


ok this can be simple or tricky is the breaker that trips the same size as the one in the breaker panel 2.look in the unit itsself see if there r breakers inside the unit there usually are and they might have tripped it might be as simple as flipping a breaker but the problem with the breaker tripping is what concerns me now it may just be undersized or getting weak and finally crapped out get ur meter and flip the breaker on and see if u r getting power to the unit if ur not u have gott a breaker that isnt letting power go thru now if u have power u might have a bad blower motor turn the unit on and calling for the fan on if the fan doesnt start try spinning the blower by hand now if it starts then u probably have a bad capacitor they r usually mounted on the side of the blower housing it is oval and its gonna be a 5mfd(microfarad) or 7.5mfd and that couldve been what was kicking the breaker now if the blower is stuck and it wont turn or its very hard to turn then make sure the blower wheel hasnt slipped on the shaft and is rubbing up against the housing if it is just loosen the set screw and set it back even and tighten it back up now if the wheel is free and its still hard to turn then u have a bad blower motor its not a big deal to change out and not real expensive if this dont help hit me back and well walk thru it hope this gets lil momma and the pets warm have a good day

Feb 26, 2010 | Heating & Cooling

1 Answer

My central heating unit is in the attic of my 2bd/2bth house. I don't know its age. It's a gas unit, but doesn't have a constant pilot flame. Rather, the pilot is ignited electronically. The problem is...


You don't mention make or model so here is my guess as to how to thinkout the trouble of what ever is in your attic.

For some reason, your heater is mis-firing. Normally, I would expect 3 to 5 such events at which time the heater goes out on safety. The heater knows it is on safety but you don't until it gets cold in your house. When you turn the power off, wait the 30 seconds, turn it back on, the heater no longer knows it is on safety (memory cleared) so it fires. Your heater continues to fire until ? at which time it starts counting again to 3 or some number. At the max mis-fire number - it goes out on safety again ... repeat - turn it off, wait 30 seconds, turn it back on - no memory and so forth.

Do you have a service contract or regular service man? Might be time to find one.

Thanks for your question at FixYa.com

Jan 05, 2010 | Heating & Cooling

2 Answers

Maytag 3000 Series front load gas dryer (Whirlpool) - No lights, no digital display, not able to turn on or start. Yes, unit is plugged in to AC outlet. Yes, AC voltage is good at 120V. Yes, circuit...


OK everyone, my ears are red. Over the weekend, I gave this another shot, since my warranty repair appointment isn't until next week.

I opened the dryer door (the drum light is off, indicating no power at all) and went to the circuit breaker box, and flipped the washer/dryer breaker back to off and then re-set the breaker again.

When I got to the laundry room - the drum light was on!

So I powered up the unit, and ran the machine. It ran for about one minute, and then went off. So I went back and re-set the breaker again.

Visually, the breakers did NOT LOOK tripped - but flipping the thing off and then on to re-set the breaker worked.

This time, the dryer is working fine. The bad part is: I need to replace the breaker for the second time. So this is NOT a defective dryer, it is a bad electrical supply. I will call the electrician back to make him fix this right. . . . .

Thanks again for all who responded. This is a new unit, purchased on 7/7/2009.

Sep 12, 2009 | Maytag Dryers

1 Answer

Blower never stops. AC outside jammed to stay on???


You need to call someone who truely knows what they're doing. From your decription, the person you had out should not be working on units. You have a problem most likely caused be the person that installed the new motor and these units are not designed to be worked on by the homeowner. There are hazards that could cause damage or injury.

Aug 18, 2009 | Goodman CLJ36AR42 Air Conditioner

1 Answer

My blower motor will not stop running,and my ignitor doesn't light.


I am assuming you are talking about a Natural Gas or LP furnace. The blower motor is powered by a separate 120 volt circuit, so flipping the 240 volt breaker for the furnace will not shut it off. There should be a regular light switch at the furnace that will turn off the blower for servicing the unit. When you take the cover off the unit, there should be instructions on how to re-set the igniter. If it won't re-set, try shutting off the gas for a few minutes, then turn it back on and then reset. If none of this works, and you can't find the owners manual, call a service technician.

Feb 22, 2009 | Electric Circuit Breaker Kit for Furnace

2 Answers

Central AC unit sent smell and smoke film


thermostat can short out turning on system a short in wiring will do same --smoke can be from fan or circuit board have a mechanic service the system

Jun 11, 2017 | Carrier Adit 600 Base +24V Phone...

2 Answers

Whirlpool Dryer not heating


first check the circuit breaker in the house, turn it off then back on. if that does not do it then let me know so we can go to the next step. Mike

Jul 14, 2008 | Whirlpool LER4634J Electric Dryer

Not finding what you are looking for?
Goodman CLQ36AR49 Air Conditioner Logo

Related Topics:

229 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

paulcarew

Level 3 Expert

2514 Answers

Brandon Berry
Brandon Berry

Level 2 Expert

407 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions