Question about Teledyne Laars Laars Lite2 Heater 175000 BTU NG Elec Ign

1 Answer

I have the Laars lite 2 175000 btu. To get the unit to work I had to play with the pressure switch. It would then start and work fine, until I turned the unit off. I would have to play with the pressure switch again to make it work. I thought the problem was the pressure switch so I replaced with a new switch, the same model even. Now I can not get the unit to work at all. I even tried putting the old switch back. Am I missing something or does it sound like I have a larger problem here. In need of some advise.. The pilot light works fine, unit will just not fire up.

Posted by on

  • keith22matti Aug 20, 2010

    Thanks, was afraid of that. Just needed to hear someone else say the same thing. Time to bring in the pro's

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Expert
  • 4,070 Answers

HI! Looks like that the problem will be on the mainboard which connects to the pressure switch. Since replacing the switch didn't resolve the problem,it's gotta be a loose or faulty capacitor on the mainboard. You will need to have the capacitors checked and replaced to make this working normally again. Hope this helps and thank you for using FixYa!

Posted on Aug 20, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Laars Lite 2 Heater will not go on


make sure little pump is moving if not check syphon tube going to pressure switch if ok check pressure switch

Jun 29, 2013 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

We have a Laars Lite 2 which will fire and run for about 5 minutes then shut down. We changed the 135 and 150 limits as we noted a drop from 24 to 14.6 V. It appears to me that the unit is over heating. We...


make sure correct gas pressure if too low it will soot up and overheat sounds like transformer is going should be 24 volts if not pressure switch wont stay on also check the manual bypass by plumbing side if spring is bad water will not go through the heater correctly

Jul 02, 2011 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Have pilot but burner will not start. Gas line is


There is an internal pressure switch for this unit that must sense water pressure before the gas valve solenoid is energized so that burner will light. If the air line to the pressure switch is leaking or has failed or is blocked it will not light at all. Additionally if you have had mice or smaller rats get into the unit, check the wiring to the pressure switch for any signs of damage. They can cause havoc! (Personal experience)

If you need further assistance please include your exact model number of your pool heater in your response.

Thanks for using FixYa.

Kelly

Jun 11, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

My pilot light is lit but the heater won't turn on.


GET A NEW PRESSURE SWITCH.. CALL AND ASK FOR A PRESSURE SWITCH FOR SAY A HAYWARD POOL HEATER .. LOOKS LIKE THIS ..EBAY Pressure Switch Hayward generic pool heaters also H100

May 20, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Piolet stays on,. burners do not go on heater will not start


could be many things ,start with pressure switch,check for continuity with multi-meter.if press switch isnt sensing water flow, your unit will not call for heat.let me know

Jul 04, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

Not finding what you are looking for?
Teledyne Laars Laars Lite2 Heater 175000 BTU NG Elec Ign Logo

Related Topics:

128 people viewed this question

Ask a Question

Usually answered in minutes!

Top Teledyne Laars Pool & Spa Experts

paulcarew

Level 3 Expert

2460 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Teledyne Laars Pool and Spa Expert? Answer questions, earn points and help others