Question about Ruud UBHC Air Conditioner

3 Answers

I have a 3 ton split system using a Rudd 3 ton condensing unit model UAHE036JAS . The compressor is going bad and I would like to replace it with a new condensing unit operating on R-22 . I do nt want to change the indoor unit as it is only 2 years old and is in perfect condition. Can I still buy a 3 ton R-22 condensing unit.

Posted by on

  • Anonymous Mar 15, 2014

    How many tons is a ruud model uahe036ja

×

Ad

3 Answers

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Teacher:

    An expert who has written 2 tips or uploaded 1 video tip.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 23 Answers

Both the other solutions are NOT proper Advice, i'm not saying this a put down, but if you want it to be right both of those answers are wrong
The truth is if you replace the condenser weather its a heat pump or strait cool, you need to match the equipment inside, ALWAYS use matched equipment otherwise your setting yourself up for failure. I've seen a ton of mechanics in my industry really mess people up by mis matching, Also you can install or service anything with refrigerant in it with out an EPA license. Trust me do it right, cause I hate having to tell people after its to late. Another thing these two are not telling you is that you need to match the metering device to the outdoor unit in order for it to work properly as well, and by the FLUSHING is risky on a coil, ok with line sets but risky with a coil.

Posted on Oct 01, 2010

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 80 Answers

Try searching on Craigslist in your area! It is a free online ad sight for local people to connect and swap things or sale things! It is great for finding HVAC systems at second hand prices! R22 condensing units are on there frequently! www.craiglist.com

Posted on Aug 22, 2010

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 407 Answers

Only if they are still available in your area. Goodman still has a few R-22 units left in Texas the last I heard and that is only if your local supply stores can order them. They are getting to be far and few between since they have stopped making the equipment. You might also get a second opinion, a lot of companies are just trying to benefit more by replacing everything, but you could still have a R-22/410A compatible indoor coil and copper line set, they just have to use a flush kit to get all the old refrigerant out of the system. 410A is easily contaminated and runs at a lot higher pressures, that is why they want you to replace everything, but there is still hope. It will save you a little money just having the system flushed and replaced with 410A condenser, but only if compatible. Hope this helps and good luck!

Posted on Aug 19, 2010

Testimonial: "Thanks for your help."

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

No heat air or fan


Should be in the indoor unit. Power supply cabinet.

Dec 15, 2013 | Ruud UBHC Air Conditioner

1 Answer

I have a tempstar 2000 heat pump approx. 6yrs.We have the compressor go bad 3 different times and replaced by the original installer.Now Action Air of Florida says they don,t know why so many compressors...


no compressors don't just go bad first of all is unit a split system or a package unit.if its a split system need to make sure copper from evap.coil to outdoor unit sized properly.next need to make sure your ductwork is sized properly undersized ductwork makes comp. run much harder.sounds like non-condensibles in system

Mar 22, 2012 | Heating & Cooling

1 Answer

Compresser on my 2 ton condenser unit not coming on condenser fan running but not the compresser. I already replaced the capacitor but did not fix the problem.


Check the wires going to the compressor terminals making sure there is no damage to them or to the compressor terminals..Install a hard startbobicehouse_2.jpg

Jul 03, 2011 | Ruud Matching Split Air Conditioner

1 Answer

Have a R-22 Rudd ait handler. Replaced the compressor with a 1.5 ton Goodman unit. My home is 1300 SF in NJ On hot days during the peak of the day the system seems to stop working for a period. The...


If your home is 1300 square feet 1.5 tons is not going to cut it you should have at least 2.5 ton A/C unit. sounds like your system is to small. let me know if this helps you out.

May 12, 2011 | Ruud UAKA037 Air Conditioner

1 Answer

Have a WeahterKing WBEA 14J055FCIA Inside split air system. Last tenant removed the outside compressor. Looks to be a 2.5 ton unit and need to find an replacement outside compressor that will match up. Is...


James if you are able, go on to craigslist and try to find you a used outdoor unit. I have several rentals and craigslist has saved me several times. I bought the last unit , 3 ton, used for $100.00.

Apr 20, 2011 | Heating & Cooling

1 Answer

Going to replace hvac system. Don't know what


Hello,
According to the model number it is a 2 ton or 24,000 BTU unit. It is very important that you change the indoor coil as well as the outdoor section, due to it being a 10 SEER unit, and the new basic systems are 13 SEER, the old coil cannot handle the higher SEER ratings.
Rheem and Ruud are the same equipment, just 1 number different on the model number.
I hope this has helped, please rate the new guy :)
Please contact me if I can be of any further help to you.
Have a great day!
Sincerely,
Paul Gibson

Apr 04, 2010 | Ruud Matching Split Air Conditioner

1 Answer

What is the size of coil in air handler is it 3 1/2 ton and believe that rudd only made 2 ,3 , 4, 5 , ton coil is this right


It is a 3.5 ton air handler and without knowing for sure about Rudd only making those sizes which they should, they more than likely would have gone up to a 4ton coil. One way to cross check this, is to see what ton the condenser outside says it is. If you have a 4ton condenser, then you should have a 3.5 to 4 ton coil, either being okay. What you don't want, is a 3 ton coil and a 4 ton condenser and so on. A half ton isn't going to be a problem regardless, but if anything, you can always take the measurements of the coil if you are trying to replace it.

Feb 03, 2010 | Ruud UAMB042 Air Conditioner

2 Answers

Replaced my 5-year old 3-ton 12 SEER Goodman outside condensing unit with an older 3-ton RUDD condensing unit because of lack of funds. Now the compressor has gone out on the RUDD. Is it better to replace...


at 5 yr on goodman unit rhe comp should of been under warrenty if theat is what was bad with it on the rudd that was a 3.5 ton out door unit are you sure the pump is bad pulling locked rotar amps or shorted to ground check the wires on the comp to make sure not burnt check the capicitor as far as replacement i always lean twoards new unit unless not going to live there long due to comp is 1 yr and labor around 850 +325 for pump i would go with another used unit over comp replacement 13 seer goodman w 99yr pump and latley have 5 yr free labor and I normally dont recommend a brand of unit on this site go to a hvac store and ask who may have a used unit I have had some still w warrenty before that came from remodel jobs in up scale areas! if helpfull rate me good luck

May 12, 2009 | Ruud UAKA042 Air Conditioner

1 Answer

Oil Leak


This would indicate a leak somewhere in the condenser sheet coil. I hate to be the bearer of bad news but you should call a service tech in to fix this problem.

Aug 29, 2008 | GE Zoneline AZ38H12DAD Split System Air...

1 Answer

Rudd 2 ton 10 S


The small copper line should not be really hot its supposed to be carrying liquid refrigerant which has already had the heat "pressed" out of it by the compressor and carried of by the air flowing over the condenser coil. This could indicate a few things; that your unit is overcharged, you have a mismatched evaporator coil and condenser, an ineffective condenser fan motor or a clogged condenser coil and as a result your compressor is shutting of due to an overload condition from the building heat and back pressure between the compressor outlet and the evaporator inlet.

First make sure your condenser is clean and that adequate air is flowing over the fins of the condenser coil. Then be sure your equipment is a matched system. A indication that your condenser fan motor is not at speed is slow starting a humming sound and excessive heat. In my experience this complaint is generally the result of a bad condenser fan motor that over heats and shuts of after a short period and the build up of heat in the liquid refrigerant line of course trips the compressor overload circuit- which by the way usually takes hours to reset. I hope you've already resolved this, but in case you haven't......

Aug 01, 2008 | Ruud Matching Split Air Conditioner

Not finding what you are looking for?
Ruud UBHC Air Conditioner Logo

416 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ruud Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Ruud Heating and Cooling Expert? Answer questions, earn points and help others