When I push start switch , the motor hums but will not start. The breaker then trips. Motor model number is 131 12171. Motor is manufactured by Mallory and is 1 hp. Manufacture model number is K 395FN 1047.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 43,501 Answers
  • Posted on Aug 17, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 12, 2009
Answers
43501
Questions
0
Helped
10837892
Points
101584

Hi,
The capacitor may have gone bad...give it a spin then turn on the swtich... if it goes the cap is the problem....if not then the motor is toast....

heatman101

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

AOSmith 1hp lift motor starts then trips breaker , any ideas?, thants

There are a few possible reasons why your AOSmith 1hp lift motor starts and then trips the breaker:
  1. Overload: The motor may be overloaded and drawing too much current. Check the load on the motor and make sure it is within the motor's capacity.
  2. Short Circuit: A short circuit could be causing the motor to draw too much current and trip the breaker. Check the wiring for any signs of damage or wear.
  3. Faulty Motor: The motor itself could be faulty and causing the overload or short circuit. Check the motor windings for any signs of damage or wear.
  4. Tripped Thermal Overload: The motor may have a thermal overload switch that shuts off the motor if it gets too hot. Check the motor for any signs of overheating and reset the thermal overload switch if necessary.
  5. Faulty Breaker: The breaker itself could be faulty and tripping prematurely. Check the breaker for any signs of wear or damage.
It is recommended to consult a licensed electrician or motor technician to diagnose and fix the issue, as working with electricity can be dangerous if not done properly.
Nov 06, 2022 • Boating
0helpful
2answers

Kenmore modle 67909 push start button makes a loud humming sound and trips breaker

A number of issues could cause that.
Door switch contaminated.
Turntable motor contaminated.
Magnetron failed.
Capacitor failed.
Diode pack failed.
Pick one and investigate bearing in mind there are LETHAL voltages inside the case!!!
0helpful
2answers

Whirlpool dryer will not start the start buttton click when pressed and the timer works if i have the door open and press the start button there is no click so i figured it was not the door swich ...

The first thing to check on a electric dryer is the power.

I know It look like you have power but you have a 220V dryer and it need both sides of power to work.

If you can't ckeck for proper power at the outlet then please at least ckeck your breaker box and maker sure you turn both switches off and then back on to make sure that one site of the breaker did not trip. Then check your dryer to see if this did not solve your problem. ((((( I flip a breaker at least once a month for a customer and recive $60.00 for doing so :) ))))))

Ok if this did not solve your problem.

When you push the button for start do you here a hum noise ??? if so Most common problem would be the motor.

No hum.... Open dryer door and turn drum by hand and close door and retry dryer.

No Hum....

Now it get real fun !!! The start switch needs to be checked, Then the Thermal Fuse and the High limit thermostat.

In most cases this is going to be forign to you and you should call a tech for service.
Sep 05, 2010 • Dryers
0helpful
1answer

20 amp Circuit breaker trips everytime I flip the motor switch on. Its a craftsman table saw motor 1HP Model 113-12070., 14/7 amps

I assume that you are using the motor on 115 volt service. Remove the drive belt and check for excess friction in either the saw arbor bearings or the motor bearings. If both seem free to turn, then suspect that the start capacitor on the motor has failed. They usually become open circuited which prevents the start rotation. It will just sit there and hum loudly until the breaker pops. You may also have a defective 20 amp breaker--you will need a clamp-on AC ammeter to verify. Suggest that you run the saw on 230 volt service when you get it running. You will be amazed at the acceleration and apparent power available. My table and radial arm saws are both set for 230 volt operation and love it. Go to: Searspartsdirect.com and enter the complete model number minus the decimal point. This will take you to a series of drawings that list all replaceable parts. Hope this helps!
0helpful
1answer

Need a point setting for ao smith air compressor ac motor model number opa-0297 s# c56b72b2316508j2 work on air machine with motor installed motor will hum and trip breaker can we set points to stop trip...

There is not a point setting for air compressors. The pressure switch can be adjusted. Remove the cover from the pressure switch. Adjust the nut tighter for a higher cut off pressure or looser for a lower cut off pressure. It sounds like the compressor is trying tostart under load. If the unloader valve is not working, the compressor will draw excess amperage and do what you describe. The unloader valve releases the pressure in the cylinder at the end of the run cycle so the compressor can start the next run cycle under no load.
1helpful
1answer

Need a point setting for ao smith air compressor ac motor model number opa-0297 s# c56b72b2316508j2 work on air machine with motor installed motor will hum and trip breaker can we set points to stop trip...

try running up this motor when its not installed on the compressor,, if it still blows the trips the motor is faulty,, if it runs ok, but hums when reconted to the compressor the compressor if far to tight for the motor to turn the compressor,,,you can not reset the points in a breaker trip they trip at a set curent if the motor is pulling more amps than the trip is set for it will trip the trip to turn off the curent, the motor will pull far more amps than it should if its over loaded thats why its humming its trying to spin up it but cant so it just keeps pulling more and more amps till the trip cuts out
1helpful
2answers

Dryer drum will not spin. motor hums when button

either the belt is broken that turns the motor or thr idler tension pulley is bad, if it were a motor problem the breaker most likely will trip
Nov 01, 2009 • Dryers
0helpful
1answer

Kenmore frt ld dryer, motor hums ,shuts off, does not trip brkr

see it all the time,the motor is getting to weak to start,that's why you get the hummming sound sometimes,you can check your locak used appliance store or maybe ebay has one,your model number is inside the dryer door,to sum it up it's the motor,let me know now you make out-mike
0helpful
1answer

Air compressor trips motor breaker

PLEASE CHECK THE CAPACTORS ON THE MTR, THE MTR WILL BE HARDER TO START AFTER IT HAS AIR IN THE TANK
Not finding what you are looking for?

511 views

Ask a Question

Usually answered in minutes!

Top Craftsman Saws Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29494 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Craftsman Saw Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...