I have a sears craftsman air compressor. It runs fine until it builds gets up to the max air pressure. It shuts off then as it should but as I use it and the air drops and it tries to restart, it barley turns over then it pops the circut breaker. It is a 33 gal horizontal model. I am not sure of the model #. I could get it if needed. Al F

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

  • Master 4,088 Answers
  • Posted on Aug 16, 2010
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

Joined: Jul 03, 2009
Answers
4088
Questions
0
Helped
1512507
Points
12435

Something may be wrong with the 'unloader' function in the air pressure control--it should drain air pressure within the exhaust tube from the compressor. You may also be running the unit on too small wiring (extension cord) and it is starving for power when the heavy load restart occurs. Hope this helps!

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
3answers

Sears air compressor 919.167340 Need advice re: why tank pressure guage doesn't work when it's compressing air.

maybe you are reading the gauge wrong
the tank gauge and the regulator gauge will read the same but the gauge that reads when you adjust the regulator is the out line pressure to be n maintained during tool use
0helpful
1answer

Craftsman 1 1/2 hp air compressor model 106.152680 builds air but when it shut off it feels like air leaking out of pressure switch someplace.

It will leak until head pressure is drained. I'd it keeps bleeding until late no more air in than your tank check is bad
0helpful
1answer

Craftsman air compressor model 919.16726 wont build pressure and makes a rattling sound

My compressor runs for about 5 min and shuts off.....does any one knows what could be the problem?

thanks
1helpful
1answer

My compressor will not go over 20 psi i have a craftsman 921 4 gal 125 psi compressor and it will not build past 20 psi i do not know how to get to the pistons and stuff what do i do?

The problem with compressors not building pressure is usually a bad pressure switch or bad regulator. Does the motor shut off at 20psi or does it continue running and not build pressure? If the motor continues to run with no increase in pressure, the you should go over the machine looking for air leaks from your regulator back all the way to the motor. Any air leak while the compressor is running can cause the pressure to "peak" way before the intended shutoff that it is regulated to.
0helpful
1answer

Craftsman air compressor 2 hp 20 gallon, seems to running o.k. builds up to 100lbs shuts off when it hits 80lbs come back on, but when i run a tool , right around 90lbs the tool dies out and runs week.when...

IT depends on the tool. Some tools require higher cfm. (cubic feet per minute) of air. IF your air line is not large enough, then sometimes 90psi is not enough to operate a tool as there is a pressure drop at the tool. Look at the required cfm for each tool. Find a chart for air line size, cfm and pressure. Most impact wrenches should be used on a minimum 3/8" air hose. You could look at your manual and see what the max pressure is on your compressor. You may be able to decrease the differential pressure e.g off and 100 and on at 90, but then the compressor will cycle more frequently, and may exceed the duty rating of the compressor.
1helpful
1answer

Craftsman 3 gal., 1.5 hp air compressor: won't auto shut off, builds only 40 lbs pressure, air leaks from the 2 holes in oil filler cap?

The compressor will not auto shut off until it reaches the preset pressure which is usually around 100-130 psi - your problem is leakage of air from the oil filler cap suggesting that you have a failed internal valve.
0helpful
1answer

Compressor will not build pressure

It sounds like it is not getting enough electricity.
Try plugging in to an outlet on its own circuit without an extension cord. make sure the circuit is rated for your air compressor. If it is on a circuit with other appliances, refrigerator, lights, ect. try shutting them all off before turning on the air compressor.


Good luck
1helpful
1answer

Compressor shuts off before reaching max pressure

Yes,but if the max is 125 you don't want to increase it above 110 and set off the pressure relief valve.
0helpful
1answer

Air Compressor will not build up over 25 PSI

your max pressure switch is faulty, and shutting off the power early. replace switch, check owners manual for location(should be near power wires)
Not finding what you are looking for?

124 views

Ask a Question

Usually answered in minutes!

Top Garden Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...