Question about Refrigerators

2 Answers

My smeg refrigerator (which is NOT a self-defrosting model) gets a build-up of icy frost in the back wall of the refrigerator portion, almost within days of fully de-frosting the whole component. Is there a way to prevent such an immediate build-up? Thanks much

Posted by on

  • ejp0915 Oct 18, 2008

    Refrig either freezes beer or it's too warm

×

2 Answers

Thanks much! Will do that right away.

Posted on Apr 26, 2008

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 149 Answers

Lower thermostat setting if it's on 9 lower it to 6

Posted on Apr 26, 2008

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a whirlpool refrigerator model #GT15HTYMQ81


The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The defrost timer The defrost thermostat (also called the bi-metal switch)

Aug 21, 2011 | Whirlpool GT1SHTXM Top Freezer...

1 Answer

I have ice forming in my freezer What should I do? Is it defrosting? Model number MBR 2562HES


Hello and Welcome to FixYa!

The heavy frost build-up that you are facing is caused due to the result of ice built up on the evaporator coils. You can't see these coils without removing/opening the panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer that is exactly the thing you quoted. Such a frost build-up usually shows a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed/designed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (usually a bi-metallic switch) The defrost heater Also you need to clean the dust, lint from the condenser unit by using a condenser brush or a vacuum cleaner to remove all the dust from the unit (it is usually located at the back of the refrigerator). If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. If the problem still persists and the above quoted techniques/tips didn't work,You may need a qualified appliance repair technician to further diagnose the problem.

Best of Luck,


Please do Rate the solution, if you feel that this helps you,


Concerned.

Aug 17, 2010 | Maytag Refrigerators

1 Answer

Whrilpool refridgerator not cooling in freezer or fridge model ET22PM


Hello and Welcome to FixYa!

The Poor cooling that you are facing is caused due to the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing/opening the panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer that is exactly the thing you quoted. Such a frost build-up usually shows a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed/designed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (usually a bi-metallic switch) The defrost heater Also you need to clean the dust, lint from the condenser unit by using a condenser brush or a vacuum cleaner to remove all the dust from the unit (it is usually located at the back of the refrigerator). If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. If the problem still persists and the above quoted techniques/tips didn't work,You may need a qualified appliance repair technician to further diagnose the problem.

Best of Luck,


Please do Rate the solution, if you feel that this helps you,


Concerned.

Aug 17, 2010 | Whirlpool Refrigerators

1 Answer

My 13 y ear old Lieherr in France has Snowy Frost buildup on the back top half of the interior wall, but the temperature in the fridge even at 7 is only 10 degrees C and will not get colder. The freezer...


Hello and Welcome to FixYa!
Since you have quoted that you have already vacuumed the condenser unit from the back and had already removed all dust & lint from the condenser unit so that possibility should be ruled out. The Poor cooling that you are facing could also be (In fact the most common reason) due to the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing/opening the panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer that is exactly the thing you quoted. Such a frost build-up usually shows a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed/designed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (usually a bi-metallic switch) The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. If the problem still persists and the above quoted techniques/tips didn't work,You may need a qualified appliance repair technician to further diagnose the problem.

Best of Luck,

Please do Rate the solution, if you feel that this helps you,

Concerned.

Aug 10, 2010 | Liebherr European Right Hinge Fully...

1 Answer

I have a GE 23 z refrigerator which is a backup in our garage. Several weeks ago it started to make a grinding noise. Recently the refridgerator portion has not been keeping things cold. The freezer is...


Poor cooling is often the result of a heavy frost build-up on the evaporator coils or a condenser that is clogged with dust, lint, and dirt. Evaporator coils Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (also called the bi-metal switch) The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problem Condenser Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.

Jun 12, 2010 | Refrigerators

1 Answer

Poor cooling in the freezer compartment


Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (also called the bi-metal switch) The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problem

Mar 29, 2010 | Refrigerators

1 Answer

Not cooling and freezing properly


Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (also called the bi-metal switch) The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problem

Mar 29, 2010 | Whirlpool 25.4 Cu. Ft. Side-by-Side...

1 Answer

The freezer is working properly but the refrigerator is not cooling properly and the air does not seem to be circulating


Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: The defrost timer The defrost thermostat (also called the bi-metal switch) The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problem

Mar 29, 2010 | Refrigerators

1 Answer

Model #596.58642890 Side by side refrigerator is not cooling. the compressor is running and the defrost timer works. How do I check the climate controls to see if they are working properly?


Hello. Thanks for choosing fixya! Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system: 1. The defrost timer 2. The defrost thermostat (also called the bi-metal switch) 3. The defrost heater If it still does not cool properly, there may be a problem with the refrigerant level or the compressor.
Hope this helps, Regards, Joe

Nov 22, 2009 | Kenmore Refrigerators

1 Answer

Fridge-side not cold enough


A refrigerator or freezer that is cooling, but cooling poorly, may have a problem in one of several areas:

Evaporator coils
Condenser
Poor cooling is often the result of a heavy frost build-up on the evaporator coils or a condenser that is clogged with dust, lint, and dirt.

Evaporator coils Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.

The refrigerator is supposed to self-defrost approximately four times in every 24 hour period. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.

Here's an inexpensive, though inconvenient, way to determine if the problem is with the self-defrosting system. Remove all of the perishable food from the refrigerator and freezer, turn the thermostat in the refrigerator to Off, and leave the doors open for 24 to 48 hours. (Be sure to have several towels ready in case the melting frost and ice causes the drip pan to overflow). This allows the refrigerator to defrost "manually." When the frost and ice build-up has completely melted away, turn the thermostat back to a normal setting. If the refrigerator then cools properly, it indicates a problem with one of three components in the self-defrosting system:

  • The defrost timer

  • The defrost thermostat (also called the bi-metal switch)

  • The defrost heater

If it still does not cool properly, there may be a problem with the refrigerant level or the compressor. You may need to consult with a qualified appliance repair technician to further diagnose the problem


Jul 29, 2009 | Hotpoint HSS25GDMWW Side by Side...

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

139 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4636 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17129 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides