Unit likely had large partical like dog or cat hair cross over cell, Unlplug and remove pre-filter & cell.
The unit has a timer that knows when power has been removed & front grille has been taken off by 2 micro switches in back of front grille that is connected to the units control board.
While you are there remove pre-filter & Cell, if ok and no debris is found & theres no need to wash, wait 10 to 15 minutes replace all & plug back in.
You should see the LED display flashing Clean Cell & Cell button flashing, hold Cell button in at least 3 seconds this may take longer to reset. Unit should turn back on.
This condition has happened to my 2 units on occasion even though I had washed the cell only a week or two previously.
The unit will turn off if a cell overload is detected by way of large static discharge. If I know the cell is clean, I just unplug the unit & take the front grille off for 15 minutes then & replace it plug back in & reset & all goes back to normal operation.
.
Was this helpful?
Yes
No
1 person thought this was helpful
Popular Solutions for Kenmore AC2044-1 Air Purifier
i have the fresh aire model just replaced rci cell cleaned filter and cleaned the ozone plate. the...
(More)
I HAVE THE FRESH AIRE MODEL JUST REPLACED rci CELL CLEANED FILTER AND CLEANED THE OZONE PLATE. THE FAN KEEPS TURNING ON AND OFF?? STARTS RIGHT BACK UP ON ITS OWN AND THROWS NO EROR MESSAGES??
side by side refrigerator....need to take out top inside of refrigerator to replace part. How do I...
(More)
side by side refrigerator....need to take out top inside of refrigerator to replace part. How do I get the top out?
Hi, I have a Hunter Quietflo Air Purifier that has quit working on me after about 3 years of use. It...
(More)
Hi, I have a Hunter Quietflo Air Purifier that has quit working on me after about 3 years of use. It seems to be getting power bc the lights turn on like normal but thats all that seems to get power. Is there a way to check if the motor is working without replacing it? thank you