Question about Sony Televison & Video

1 Answer

Self-diagnosis red indicator flashes 10 times then pauses for 3

I have a Sony Wega Projection TV KP-FX432. When I switch on, the self diagnosis red indicator flashes 10 times then there is a click and the TV switches off. 3 seconds later the red indicator flashes 10 times again. This keeps repeating. Sometimes the TV stays switched on but the red indicator continues to flash 10 times then pause for 3 seconds. Can you help me please. Regards, Cliff

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 666 Answers

The blinking light signifies to a repair technician with capacitors or circuits are having an issue they can diagnose the problem via the amount of blinks in between pauses however it will require a technician and some specific tools and schematics to fix and it may be cheaper if its no longer under warranty to purchase a new one


Hope this helped
Robb

Posted on Jul 14, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

TV turns red,shuts off, stand-by light blinking 8Times


Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

Feb 27, 2014 | Sony KP-51HW40 51" Rear Projection...

1 Answer

Red flashing light


  1. Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.

Jul 17, 2013 | Sony Televison & Video

1 Answer

SONY KP-61HS20 DOESN'T COME ON JUST BLINK 6 TIMES PAUSE AND 6 TIMES AGAIN


Sis blinks of standby light denotes No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. If you wish to get more details about blinking codes to Sony PTV, check this link.

Mar 03, 2013 | Sony KP-57HW40 57" Rear Projection...

1 Answer

I hit the power button,and it just flashes a red light by the power switch witch says standby


How many times does it flash in between each pause? Its a self diagnostic error codethat will tell me what the problem is. So please let me know

Feb 23, 2011 | Sony KP-61XBR48 61" Rear Projection...

1 Answer

MY SONY PROJECTION TV WEGA KP-FX432 BLINKS 10 TIMES THEN TURN OFF.PLEASE HELP ME


Try connecting the TV directly to a different wall outlet and check. If the issue persists, try power resetting the TV. Turn Off the TV and remove the power plug from the wall outlet for 1 minute and reconnect it and check the operation. If the issue persists, then the TV requires service.

Jul 22, 2010 | Sony KP-FX532M91 TV

1 Answer

Sony FD Trinitron WEGA Tv - LAMP blinking 11 times


Sony tv has self protection program. The red Led blinking light indicate the probable cause location. For this model it is either 2,4 or 5 flashes every 3 second. Please check the blinking again

Feb 09, 2010 | Sony FD Trinitron WEGA KV-27FS120 27" TV

1 Answer

Sony lcd projection tv in self diagnosis mode. 4 red flashes


This is a fan error take the back off the set and see if the fan is turning.

Sep 13, 2009 | Televison & Video

1 Answer

Sony 50 Wega LCD flashing red light


Hi

How many times is the red light flashing? The number of times the red led blinks means---


  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.

  • One blink - not used for the self-diagnosis

  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.

  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505

  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.

  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.

  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.

  • Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.


  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.
  • No blinks(Unit is dead) - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
Please do rate this solution as FixYa and revert for further assistance.

Thanks
Rylee

May 01, 2009 | Sony Grand WEGA KDF-50WE655 50" Rear...

1 Answer

My 61 In sony xbr flashes the standby light 5 times


Many of the later model Sony TV’s have a built in self-diagnosis function. If the timer/standby indicator is blinking, this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action required by you to engage it.
The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again.
Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.
  • Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
  • Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
  • One blink - not used for the self-diagnosis
  • Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
  • Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
  • Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
  • Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
  • Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
  • Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.
  • Eight GA_googleFillSlot("TL-IMU-Article");blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.

  • Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).
  • Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Mar 28, 2008 | Sony KP-61XBR48 61" Rear Projection...

Not finding what you are looking for?
Televison & Video Logo

Related Topics:

147 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

74377 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions