True upright freezer. coil fan not running.

I had just installed a true upright freezer. everything woks good but coil fan not running. Can you please tell me what im forgetting to do?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 1,524 Answers

Let it run. Coil temperature has to be low enough for the fan delay switch to close.

Posted on Jul 14, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fan not working


Generally I would check for power at the fan wiring because there are several components that can keep it from running. If the fan does have power change the motor. But if it doesn't is the coil frosted and cold enough to let the fan thermostat switch close?
Is the door switch good? Hope this helps good luck.

Aug 06, 2014 | True T19F Commercial Freezer

1 Answer

Loud clanging noise from Kenmore upright freezer


Check the condenser fan (outside at the rear) and check the coil isn't baking hot. Electronics or board wouldn't cause your symptoms. Check the simple things first!

Jul 10, 2012 | Freezers

2 Answers

Delay on evap. fan sistm.404a


Give the evaporator a chance to get cold, then check you've got power to the fan, via the evaporator thermistor and door switch

May 02, 2012 | True Freezers

1 Answer

No evaperater fan run,compressor running,coil is frosting but no voltage to inside fan.


Look to the fan delay/defrost terminator that is located inside to the evap. It is usually attached to the evap coil. check there first.

Aug 25, 2010 | True 206 cu. ft. Freezer TWT-67F

1 Answer

Fridgeaire upright freezer is getting warmer and warmer.How do I


there is no way of cleaning the coils.there maybe a problem with the compressor.you should hear a fan running inside the freezer when it is in the cooling cycle and the compresor is running if you do not here the fan running this could cause a cooling issue and the evaporator could be building up with ice.
check the rear of the freezer to see if there is any ice build up.

Jan 18, 2010 | Frigidaire 20.6 cu. ft. / 583 liter...

1 Answer

I have a frigidaire freezer upright model#ffu20f9gw3


Without any additional info, there are a lot of possibilities:
1. Condenser coil (underneath unit) is dirty and clogged.
2. Compressor is failing. (need A/C tech)
3. Metering device is clogged. (need A/C tech)
4. Refrigerant charge is low. (need A/C tech)
5. Door seal is broken (frost will form around door).
6. Defrost heaters are stuck on (replace defrost timer located underneath unit at front).
7. Condenser fan has failed (underneath freezer on back).
8. Evaporator fan (inside fan) has failed (ice will form on cooling coil).

This should get you started...

If this helps you, please select YES to the first two ratings questions. Thank you, and Good Luck.

Oct 13, 2009 | Frigidaire Freezer 20.3 Cu. Ft. Frost Free...

1 Answer

1999 Kenmore upright freezer alarm lite on, how to diagnose problem. Sealed unit and see no fan by compressor? Lower coiles seemed cold w/ some ice but higher shelves(coils) not so cold? 23 year Master...


the reason there is no fan on the outside is because the outer shell of the unit is the condenser. the unit does it have a fan on the inside? also how does that gfasaket on the outside of the door look like? let me lknow

Jan 11, 2009 | Kenmore 20.3 cu. ft. / 575 liter Upright...

1 Answer

Fan continuously running, non-stop


hi thanks for the question its normal for a frost free freezer to run a long time to keep a good cold temp i don't think you have a problem thanks the appliance doc

Sep 08, 2008 | Frigidaire 13.7 cu. ft. / 388 liter...

1 Answer

Kenmore Freezer Model 23041


I have an upright freezer which temp was unstable. The coils were frosted up, and the circulating fan was unable to pull air across the cooling fins.I defrosted the unit, cleaned it up, and turned it back on. Worked fine until it frosted up again. The unit was a no frost model. I had to have it serviced, and one of the defrost sensors was bad. No problems since this was fixed.

Aug 13, 2007 | Kenmore 20.3 cu. ft. / 575 liter Upright...

Not finding what you are looking for?
True 49 cu. ft. / 1388 liter Commercial Freezer GDM-49F-RC Logo

Related Topics:

358 people viewed this question

Ask a Question

Usually answered in minutes!

Top True Freezers Experts

Dennis Boxerman

Level 3 Expert

1151 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

John Tripp
John Tripp

Level 3 Expert

4654 Answers

Are you a True Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...