Question about Hunter Pump Start Relay Psr-22 Pump Controller

1 Answer

Why my PSR-22 pump start relay does not start the pump even the automatic sprinkler controller is at manual run mode?

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

It could be that the PSR-22 isn't "relaying" the correct amount of power to your pump. If the PSR-22 is making noise (a hum, or buzzing sound), it could be failing.

Try checking the voltage on the PSR-22 to be sure that it's supplying your pump correctly. Be careful - there's a lot of voltage in there, and getting a shock could be fatal.

Posted on Jul 19, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have aa 2007 chev her with 2.22 liter some of the fuses don't get power and some do on the fuse box block under hood everything to start and run car is dead


2007 Chevy her ? HHR ? 2.2L 4cylinder , check the run/crank relay ! Relay # 51 in the under hood fuse/relay box.
Power to many of this vehicle?€™s circuits are controlled by the module that is designated the power mode master (PMM). This vehicle?€™s PMM is the body control module (BCM). The PMM controls which power mode (Run, Accessory, Crank, Retained Accessory Power, or Off) is active.
Run/Crank Relay The run/crank relay control circuit is connected to a constant ground and is switched by the ignition 1 circuit or the body control module (BCM). The BCM, will in lieu of the ignition switch position, activate the Run/Crank relay during a remote start event. The Run/Crank relay supplies a power signal to the following circuits, when the a Run or Crank power mode is selected:
?€¢
Automatic transmission shift indicator


?€¢
Automatic transmission (A/T)


?€¢
Switched power feeds to the BCM


?€¢
Electronic brake control module (EBCM)


?€¢
Electronic ignition module (spark control)


?€¢
Electronic power steering module (EPS)


?€¢
Fuel injectors


?€¢
Powertrain control module (PCM)


?€¢
Park neutral position (PNP) switch

Dec 22, 2015 | Cars & Trucks

1 Answer

When i turn the system to run hear a click in the pump relay but system does not come on


Turning the dial to run should not send any electrical current anywhere it simply is set to come on at the scheduled time. If your turning the dial to run and attempting to start the valve manually and a click the pump or valve solenoid clicks, the flow control may be closed, the water is off or the valve has failed to open. Try opening the bleeder screw to see if the valve opens this way. If so, try replacing the solenoid if no, replace the valve.

Aug 29, 2013 | Orbit Irrigation 57009 WaterMaster Pump...

1 Answer

Intermatic dial doesn't automatically switch sprinklers


1) Trippers can wear down. Transformer can go bad if model has 24Volt output. Relay can go bad.
http://waterheatertimer.org/pdf/How-to-Set-and-Troubleshoot-Intermatic-sprinkler-timer.pdf
http://waterheatertimer.org/Intermatic-trippers-and-parts.html#sprinkler

2) Add a comment Feb 2013 with model number, and include if this is new timer or older timer that worked before and stopped working.

Feb 10, 2013 | Intermatic T101 - 24 Hr. Dial Time Switch...

1 Answer

Model 57882 9 station timer I did set up station 1 where do I begin in order to set up station 3


Question is not clear.
Do you have programming problem with the timer?
Or problem locating sprinkler heads?
Or a sprinkler valve problem?
Add a comment with detailed information.

Sprinkler timer turns ON-and-OFF.
Timer does not advance the sprinkler to next station. The sprinkler valve advances to next station when timer turns OFF.
For example, when timer turns ON, then station 1 starts watering.
Timer turns off, and then sprinkler valve automatically advances to station 2.
Timer turns on again, and station 2 starts watering.

Orbit resources:
http://www.orbitonline.com/support/
http://www.orbitonline.com/lib/media/InstallationGuide.pdf
http://www.irrigationdirect.com/media/manuals/owners-manuals/orbit/Orbit-WaterMaster-57880-Controller-Owners-Manual.pdf

Aug 02, 2011 | Orbit 57882 9 Station Super Dial...

1 Answer

Automatic sprinklers (Intermatic timer) do not work in automatic, but manual does work. When I cycle the timer, the solenoid activates but not enough for the sprinklers to spray. Manual works fine. Any...


If manual override works, and dial rotates on time each 24-hours, then worn trippers are suspect.
http://waterheatertimer.org/Intermatic-trippers-and-parts.html#sprinkler
http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html

Upvote the help.
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

May 28, 2011 | Intermatic R8806P101C -...

2 Answers

I have a 1993 VW Passat VR6, My problem is when I try to start it, I have no spark from the spark plugs..What could be the problem or how do I fix this?????


GO TO THIS SiTE TO CHECK THE FUSE BOX!
http://vwtech.no-ip.info/images/golf/post90.gif

This are the FUSE and RELAY number SLOT!
Fuse No. Description Ampere Rating 1 Headlight, low beam, left 10 2 Headlight, low beam, right 10 3 Instrument panel lights, license plate lights 10 4 Glove compartment light 15 5 Wiper/washer 15 6 Fresh air blower 16-valve only: Air conditioning 20 7 Taillights, side marker light, right 10 8 Taillights, side marker light, left 0 9 Rear window defogger 20 10 2.0 16-valve only: Fog lights 15 11 Headlight, high beam, left,High beam indicator light 10 12 Headlight, high beam, right 10 13 Horn 16-valve only: Radiator cooling fan 10 14 Back-up lights, washer nozzle heaters 10 15 2.0 16-valve only: Engine electronics, stabilizer valve, cold start valve 10 16 Instrument panel warning lights, 16-valve only: Multi function indicator 15 17 Emergency flasher switch, turn signals 10 18 Fuel pump, oxygen sensor heater 20 19 Radiator cooling fan, air conditioning 30 20 Brake lights, cruise control 10 21 Interior lights, digital clock 16-valve only: Luggage compartment light,multi function indicator, central locking 15 22 Radio, cigarette lighter 10
Relays Relay No. Description 1 Air conditioning 2 Open 3 Digifant control unit 4 Load reduction relay 5 Low coolant level control unit or Open 6 Emergency flashers 7 Rear Wiper 8 Intermittent wipers 9 Seat belt warning system control unit (possibly headlight warning too?) 10 Fog lights 11 Horn 12 Fuel pump (except diesel)Glow plugs (diesel) 13 Radiator cooling fan after run (except 16-valve)2.0 16-valve: Starter interlock relay 14 Automatic trans., coolant temperature indicator,starter interlock relay (except 2.0 16-valve)2.0 16-valve: Radiator cooling fan after run 15 ABS pump relay 16 ABS relay 17 Heated seat control unit, driver 18 Heated seat control unit, passenger, or power seat circuit breaker 19 Automatic transmission 20 Open 21 Power window relay, ABS hydraulic pump fuse 22 ABS valves fuse 23 Air conditioning, power seat fuse 24 Power window fuse

Nov 17, 2010 | 1993 Volkswagen Passat

1 Answer

I have installed a Hunter psr22 pump start relay and connected it to a Hunter src irrigation controller and when I cycle the irrigation controller to manual all stations it will not start the pump. There...


So the mv and c are supplying power to the transformer/relay and out of it, but the pump won't start until the relay is forced.
I'm thinking the relay contacts are oxidized, and need to be cleaned. When they have oxidation, current goes up, and voltage might appear ok. If any start capacitors are in the circuit, they can be faulty, breaking down under a load, while reading ok. I haven't heard of any caps in these systems, but just in case.
The following blog may help you- it's about different controller situations:
http://forums2.gardenweb.com/forums/load/water/msg121639307045.html?9
Hunter's website has some things to check concerning the controller:
http://www.hunterindustries.com/resources/library/product_technical.html
Looks like it could be microprocessor lockup. It's quite a process, but here's what they say is the fix:
http://www.hunterindustries.com/resources/library/Technical/200611_hdln_micropro.html
Good luck, hope this helps, and thanks for using FixYa.

Sep 14, 2010 | RTO Hunter Psr-22 Pump Start Relay

1 Answer

Sprinkler timer will not start pump. i need wiring help


have the same problem,, but the small button on the bottom of the start relay works to run the pump or if i put the two start 24 vt wires to the timer 24 vt spaces,, but can not get the timer to turn on the pump when it turns on the water, even tried the orbit help center, and they said it was faulty timer, so i replaced it ( another wasted 2 hrs to return the old and hook up the new one) only to find out it too was exactly the same results. Next round,, i look for a diferent brand timer and pump relay switch,,, hope this will solve my problem

Sep 12, 2010 | Orbit Pump Start Relay

1 Answer

I have 1 and 1/2 horsepower sprinkler pump that wont prime. As soon as the end piece fills, it will empty if I open the end to the sprinkler.


I don't know what is your system set up. However, the system set up should be the following;
1. Your 1-1/2HP sprinkler pump must be installed at
a fix location nearest the water source. (Complete
with power and plumbing lines.)
2. At the end of the suction line is a vertical check
valve with strainer.
3. The suction pipeline must be connected to the
suction port of the pump.
4. At the discharge port, a flow control valve tee must
be installed. The flow control valve tee top is
covered with a plug, which serves as the priming
port when opened.
5. After the flow control valve, connect a short nipple
so that you can put a gate valve to stop the water
flow or allow the water to flow. You may connect
a pressure tank at this point or you may connect
the pressure hose going to the sprinkler.
6. To prime the pump, open the plug at the flow
control top. Fill it full with water, replace the
priming port plug.
7. Turn the flow control valve to full closed position.
8. From full close position, switch the power on.
9. The pump now run on and off due the pressure
switch setting. Slowly open the flow control valve
such that the water pressure remains steady.
10. Take note of the pressure.
11. Shut the power off, and connect the sprinkler
pump hose.
12. Put the power back on, and allow the pump to
run with the sprinkler.

Under this set up, you can run the sprinklers when your pump is running. Hope this will solve problem.

Dec 08, 2009 | Plumbing

1 Answer

The headlights do not activate automatically, in the auto mode, at night or with minimal daylight. However the running lights will activate in the auto mode. A new dash light switch was installed without...


The light sensor to control the automatic headlamps is located on the dashboard. This sensor is suppose to activate running and headlamps. I would suspect the problem is a relay to operate the headlamps if the car uses a seperate relay in the automatic mode. I'm assuming the headlamps work in manual on/off. FYI... The auto mode does not control the fog lamps.

Nov 15, 2009 | 2001 Mercury Sable

Not finding what you are looking for?
Hunter Pump Start Relay Psr-22 Pump Controller Logo

522 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hunter Garden Experts

Dennis Key
Dennis Key

Level 3 Expert

2475 Answers

john h

Level 3 Expert

10934 Answers

yadayada
yadayada

Level 3 Expert

74945 Answers

Are you a Hunter Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...