Could be a bad regulator

Posted on Aug 15, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Heater takes a long time to fire up.


There is a flow switch if that's not working. same problem needs to be tested Gas valve solinoid could cause this Igniter could cause this problem Gas pressure regulator wrong pressure should be about 2.7KPA LPG Gas valve should be set to about 2.6 KPA LPG

Mar 28, 2013 | Rheem M206A 206K BTU Pool and Spa Propane...

1 Answer

Gas Dryer Ignition Issues


did you try bypassing the cycling t-stat also?

Aug 25, 2012 | Samsung Dryers

1 Answer

Just bought a new Jenn-Air grill and cant get the temp past 250. Any ideas what i am doing wrong?


First, check that all the gas lines and flame bars are clear of any 'things' or bugs. I had a similar problem with a Webber grill and found out my problem was with the gas bottle. The new Overflow Protection Valve required on LP bottles can closed off or severly slow the flow of gas when the bottle is full and the valve is opened quickly. It will let enough gas flow to light the grill but won't let the fire get high enough to heat the grill up. Turn all the valves off on the grill and gas bottle. Open the gas bottle valve slowly then turn on the grill burner and try lighting it. If the flame is still very low try again or you have to let it burn at the low level until the OPV float drops down and the valve doesn't impede the gas flow. The best way to avoid this in the future is to not fill the gas bottle to the top when you have it refilled. Just ask the LP attendent to not fill it all the way.

Jun 06, 2011 | Garden

1 Answer

No flow of gas to fire after pilot light is lit and turned on.


i have had a legend vantage slide control gas fire for about 5 years.this problem is i believe a blocked oxy get which is a failsafe device to prevent a gas leak.can be remedied easily by a gas safe engineer.

Jan 07, 2010 | Vantage Televison & Video

2 Answers

Genesis s310 stainless grill. Does not fully light.


Regulator is not bad, as I stated before new valves are designed to reduce gas flow if valve is opened to fast. This is so if grill catches on fire, the tank will shut itself off, thus propane will stop flowing causing fire to extinguish itself.

Dec 28, 2009 | Weber Genesis E-310 Gas Grill

1 Answer

Gas Furnace Will not light


Hi, normally when you turn the gas off at the flex line valve and leave it off for awhile, the gas has to clear the gas valve and lines up to the pilot. Purge its self of air before it will light again. It will take the electronic ignition several clicks and more before there is enough gas to light the pilot and then open the main gas valve to fire the burners. Tell me, what kind of gas furnace is this when you speak of water? you say the site glass was full and you had to drain it and then the ignitor kept on clicking when it normally only took one click to light it. Please let me know the style as in a split system, a package unit, all in one, or what you have. I will wait to hear back from you. If the pilot does not light right away, then yes let it continue to click and see if it will light. On a heater with the electronic ignition control module on it or a circuit board, this is what tells the pilot coil to energize to light the pilot. It will send power to the pilot coil to open and let gas through to light and same for the main gas valve, will get a signal to open when the pilot is on. It will not open unless the pilot is lite for saftey. I will wait for you're responce.
Shastalaker7

Nov 27, 2009 | Honeywell CT87B ROUND HEATING&COOLING...

1 Answer

Grill's fire won't stay lit


Try banging on the tubes feeding the burners with a heavy pair of vice grips or a hammer. It usually shakes the carbon loose to allow for free flow of gas.

Aug 09, 2009 | Grilling

1 Answer

Gas dryer Problem


check your dryer vent , check to make sure it is not full of lint or crushed. check the outside also make sure there is good air flow coming out.

Jan 09, 2009 | LG DLG5932S Gas Dryer

Not finding what you are looking for?
Weber Genesis Silver B Grill Logo

Related Topics:

64 people viewed this question

Ask a Question

Usually answered in minutes!

Top Weber Grilling Experts

paulcarew

Level 3 Expert

2458 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Treefrog15
Treefrog15

Level 2 Expert

127 Answers

Are you a Weber Grilling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...