Question about Heating & Cooling

1 Answer

Our fitzroy cannon pilot light will not remain on once we release the control knob

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 674 Answers

Sounds like the thermocouple that senses the pilot is bad. You should replace it.

Posted on Jul 06, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Pilot light blew out by a fan..I turned the control off..How do I Ignite Please


First locate where to light pilot. You can do this by following thin aluminum colored tubing from control valve to inside heater.In general on top of your gas control valve is a knob. Turn indicator of this knob to pilot and depress knob. This will start gas flow to pilot at end of thin tube. Hold this knob in the depressed position and light pilot. DO NOT release knob for 30 -45 seconds. Then release knob and pilot will remain lit. Then turn knob to on position. If pilot will not stay lit you may need a new thermo coupler, which senses heat from flame to keep pilot gas flow open.
Good luck

Mar 10, 2015 | Heating & Cooling

1 Answer

American range fryer will not light...the knob you turn to light the pilot light will not turn.you can push it in but won't turn.please help


From the Owners' manual:
LIGHTING
1. Before attempting to light this appliance, the door if so equipped, shall be open.
2. Turn the appliance manual gas shut-off valve to the OFF position.
3. Turn the combination gas control knob to the OFF position.
4. Turn the thermostat control to the OFF position.
5. Wait 5 minutes.
6. Turn the appliance manual gas shut-off valve to the ON position.
7. Turn the combination gas control knob to the PILOT position.
8. Light the pilot with a match while depressing and holding the combination gas control knob until the pilot remains
lit upon releasing the gas control knob.
9. Turn the combination gas control knob to the ON position.
10. Turn the thermostat control knob to the desired temperature to turn burners ON.
11. Ensure that the door is closed during operation.
12. For complete shut-down, repeat steps 2, 3, and 4.

It won't turn any further until the pilot is lit and stays lit.

Jun 14, 2014 | Kitchen Appliances - Others

1 Answer

We have a Rinnai R82VF LPG room heater. When you press the gas button and then turn the temperature control knob to IGN, it lights. When you release the temperature control knob, it springs back to OFF and...


Part of the problem may be, that when you turn the control knob to ignition, you're not holding it in long enough for Thermocouple or Thermopile to thoroughly heat up after the pilot lights. You should hold the bottom down for 30 seconds to a minute, to allow it to heat up. Then, when you slowly release it. If the pilot remains lit, turn the knob to the desire position.

If the above doesn't solve the problem, the Thermocouple or Thermopile (aka Pilot Generator) will need to be replaced.

Hope this helped you. Cheers

Jul 08, 2011 | Heating & Cooling

1 Answer

Can't locate pilot on vulcan lg300


TO LIGHT THE PILOT
1.Open the door. 2. Turn the thermostat OFF The thermostat is located behind the door. 3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas to vent. 4. Push and turn gas control valve knob to the "L" in PILOT. 5. While still holding the knob in, light the pilot with a lit flame. Continue to depress the knob until pilot remains lit when knob is released. If the pilot does not remain lit, repeat step 3 through 5. 6. Depress and turn gas control knob to ON

Jun 02, 2011 | Frymaster FPEL217 Deep Fryer

1 Answer

I accidently turned the pilot off and I can't get it to turn on Williams Model# 2001622


Turn the control valve to the PILOT position and push down and hold it in. Press the Ignitor Button and continue to hold the Control knob down, once the pilot lights. Wait one minute, release the Control Knob and if the pilot remains burning, turn the Control Knob counterclockwise to the ON Position. If after the burners light and burn for a few minutes, you can turn the Control Knob back (Clockwise) to the Pilot position (if you don't want the heater to come on automatically) and the pilot should remain lit.

Hope this helped to get you back up and burning.

Mar 30, 2011 | Williams Heating & Cooling

2 Answers

Lennox G8Q3-90-4 will not ignite the pilot. The


While holding down the control knob for the pilot, you either have to use the pilot ignitor or match light the pilot. Then old the knob in for 60 seconds, before releasing it. If the pilot remains lit, turn the control knob to ON. If the pilot does not remain lit, the Thermocouple or Thermopile may need to be replaced.

Hope this helps you to solve the problem.

Mar 23, 2011 | Heating & Cooling

1 Answer

How di i light the pilot light


Be sure that the gas line to the heater is ON.

Looking at the Control Knob on top of the heater, you note that he knob has 3- positions: OFF, Pilot, ON.

Turn the control knob to the Pilot position and push down on it. If it does not go all the way in and your do not feel strong pressure pushing back at you, it is not directly in the pilot position. (Reposition the knob slightly and try again). Once You're sure the knob is directly in the pilot position and the knob is depressed, continue to hold it in and press the Ignitor button next to it. You will hear a loud click. If possible, watch the pilot assembly inside the heater when you do this. That way you can see if the pilot lit the first time. If not repeat, pushing the ignitor.

If the gas line had been turned off to the heater, the pilot may not light the first couple of tries, due to air being in the gas line. If that is the case, hold the control knob in until you smell gas, let off, wait 5 minutes and repeat the lighting sequence.

Once the pilot does light, continue to hold the control knob in for 1 minute. This will allow the Thermocouple to heat up completely. Ease off the control knob and the pilot should remain lit. If it does, turn the control knob to ON and the burner will light.

Now you're ready to set the temperature or comfort level. You do this by raising or lowering the flame height. The higher the flames, the more heat it puts out. The lower the flames, the less heat it puts out. The stripe on the knob represents the flame heights - Narrow stripe, lowest setting, widest strip, highest setting. Or your specific model may simply say Low, Medium, High.

If you do not have the Owners Manual for this heater go to http://www.desatech.com/
click on Wall Heaters and enter the Model Number of your heater. You can then download and print the Owners Manual.

Hope this helped to get you up and runnig.

Feb 20, 2011 | Vanguard International Blue Flame - Large...

2 Answers

How do i light the pilot light on my Cannon Fitzroy gas log fire


Users manual link attched. This is for the built in put operating instructions should be the same for free standing.
Cheers, hope it helps.

http://www.sampfordixl.com.au/cannon/upload/CannonFitzroyProfilePowerflue.pdf

Jul 26, 2010 | Heating & Cooling

1 Answer

Light pilot light


Turn control knob to "Pilot" and press it down. While holding knob down, light pilot with a match. After pilot lights continue to hold knob down for about one minute. When you release the knob the pilot should remain on. If it goes out then the thermocouple needs to be replaced.

Jul 18, 2009 | Pool & Spa

1 Answer

Torpedo heater lights and runs with control kknob pressed in but shuts down when control knob is released.


Change the thermocouple. The thermocouple scenes the heat from the pilot lit and signals the main gas valve to remain in the ready condition. The main valve will not receive the signal if the thermocouple is bad and will revert to the safety shut down when the control knob is released.

Nov 20, 2008 | Dayton Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

309 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2457 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others