Dear sir/madammy apc ups is beeping every 2 seconds and the indicator is changing from amber to green alternately. could you please help me out in solving this problem?

Posted by Anonymous on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 621 Answers

Sounds like faulty memory module if you have more than 1 take others out and try one at a time till you find the culprate. If you only have 1 replace it. Please vote.... thanks from Scott

Posted on Jul 05, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Apc xs1500 beeps 4 times


Check if the unit has a breaker on the back and reset it. The unit doesn't seem to be getting power.

Dec 03, 2012 | APC 1500VA BX1500 8 Outlet UPS UPS System

1 Answer

I have an Symmetra RM APC and there is an amber light showing and a beeping about every 30 seconds.


Hi Ewiesemann,

The amber light on the UPS usually means that the unit is 'on battery' -- meaning that input power is affected. Check to make sure that unit is plugged in and check to make sure that a breaker on a panel feeding the UPS power hasn't tripped.

Hope this helps.

Jul 28, 2011 | APC - UPS - Matix/Symmetra Enterprise UPS...

1 Answer

Hi, I've APC UPS ES 500 connected to my desktop computer. Have 1 year old battery but when checked without load displaying 12 V. Issues are: a. ups doesn't supply...


A battery showing 12V without a load attached means nothing. You probably have one or more weak cells and they simply cannot supply enough power. I would try a new battery before I try anything else.

Jul 21, 2011 | Office Equipment & Supplies

1 Answer

I think my apc battery is not charging but green light is on . when i switch off it immediatly goes off. why?


Sir some details required to solve your ups problem.

1.What is the current back up time and load?(if the ups giving back up)
2.Is the amber light glowing at the time of switch on the ups?

Dec 08, 2010 | APC (BE500U-WEB) (BE500UWEB) UPS System

1 Answer

Alternating green and orange light with constant beeps


Verify that the usb to ups cable is pluggled in properly. Also you may not have a good ground. Disconnect the ups and plug it in another outlet to test with nothing else plugged into it, to see if it still beeps. You can also try and upgrade the ups software from apc.com

Jun 25, 2010 | APC Back-UPS ES 350 - UPS ( external ) -...

1 Answer

Keeps beeping every 2 seconds...


It sounds like its possible your battery is discharged or close to the end of its life, and needs to be replaced, but without better details its impossible to know the exact cause.

A user manual for your ES 650 is available here: http://www.refurbups.com/KB-M-Backups


Mar 28, 2010 | APC BE650BB BACK-UPS ES USB 650VA WITH...

2 Answers

In My APC UPS, continuous beep sound is coming with simultaneous Orange and Green lights are appearing


Unfortunately that signals an internal fault with the UPS and it requires immediate replacement / repair. Do not continue to use the UPS at all.

Mar 01, 2010 | APC (BE500U-WEB) (BE500UWEB) UPS System

1 Answer

Hi in my apc es 500 the amber and green light is alternatively flashing and my ups is not working on battery power it is shutting down automatically plz help


Batteries in the UPS typically last 3 to 5 years and it depends upon several factors. including the number of times the unit must go on battery power and environmental conditions. There are usually several batteries in the UPS and while the battery voltage may show 13 volts, this may only be a float charge/voltage and a true indication of the battery voltage and condition requires the batteries to be tested under a load. There maybe one battery in a set of batteries that is faulty and causes the whole battery system to fail and indicate a battery fault.

These lower powered and cheaper type UPS are switch over types, when the mains supply fail, the UPS switches over to the battery and inverter in milli-seconds which then supplies mains power. A faulty inverter circuit and or flat batteries won’t deliver standby power when the mains supply fails.

Nov 12, 2009 | APC Computers & Internet

Not finding what you are looking for?
Computers & Internet Logo

Related Topics:

46 people viewed this question

Ask a Question

Usually answered in minutes!

Top Computers & Internet Experts

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

kakima

Level 3 Expert

102366 Answers

David Payne
David Payne

Level 3 Expert

14161 Answers

Are you a Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...