Question about Kidde Nighthawk Combo Gas/co Detector

1 Answer

Alarm keeps beeping, reads 0

Our alarm (900-0113) has sounded briefly (3 short beeps) 3 different times today.  The display continues to read "0", nothing else.  I changed the battery thinking that was the problem, but it happened again since then.  I am thinking that it is malfunctioning since it still reads 0 after testing it.  There is a blinking red light next to the 0 which, according, to the manual, means it is working.  I have two small children at home so do not want to misdiagnose.  Thanks.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 667 Answers

Try testing it first. Press the test/reset button. If it's operating properly on the display:
"GAS" - and it should beep 3 times. Then a number should appear on the display. It should be arround 200. Then it should beep 4 quick times, then nothing for 5 seconds, then 4 quick beeps that keep repeating. It will then show 3 numbers again for a few seconds. When they're gone it will be done resetting. It should show a flashing red light and a 0 or whatever the reading might be. Try this and let me know what happens. If this fixes the problem please rate as fixed. If not, please don't rate yet. Let me know what's going on and I'll be more than happy to help. Thanks.

Posted on Apr 16, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

To turn the beep sound off when system is set to armed


Troubleshooting FAQs - Solve Problems Quickly by ...

www.adt.com/help/faq/troubleshooting

The ADT CorporationHow do I silence low battery beeping? ... Why is my ADT Pulse security systemreceiving an unavailable message? ... How do I fix a disconnected camera? ... by a motion detector while the system is armed, the burglary alarm will sound. ... Some common events that may cause a motion detector to set off a false alarm ...

Five Steps: How to Stop a Beeping Security System

https://www.vectorsecurity.com/.../Five-Steps-How-to-Sto...

Vector SecurityFeb 9, 2015 - The shrilling sound of a continuously beeping security system is enough to drive anyone crazy. A power outage, faulty wiring or bad batteries ...

The Top 15 Questions about ADT Home Security Systems ...

zionssecurity.com/...security/the-top-15-questions-about-adt-home-securi...
Oct 10, 2012 - How do I turn off the voice descriptions but keep the chime sound on?... If your time on the Lynx system is not set all you need to do is push your user code + # + 63. ..... When our security alarm is not armed it beeps every few seconds ....Reasons to Install Security Cameras in your Home · Small Business ...

Jan 03, 2016 | Home Security

1 Answer

My alarm beeps at night for a short period


if it is about a smoke alarm with a battery in it, when the alarm beeps for no apparent reason, it is a bult in indicator that the battery is flat or approaching a low voltage and needs replacing
If it still beeps after replacing the battery have it checked out as a fire alarm is critical for your safety

Jun 12, 2015 | Kidde 1276-9995 Hardwire Smoke Alarm with...

1 Answer

I have model kn-cob-lcb-ca...it does not have a digital display, it was made in 2009..a few nights ago it started beeping...4 beeps, 5 second pause then 4 beeps continuously..the manual says this is a...


send the detector back and have it replaced,
The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO: 70 ppm CO Concentration 60 - 240 minutes 150 ppm CO Concentration 10 - 50 minutes 400 ppm CO Concentration 4 - 15 minutes The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps - followed by five (5) seconds of silence - followed by four (4) short beeps. The unit shall incorporate 2 LED's. A green LED will be illuminated to indicate the alarm is operating properly when plugged into an outlet, and will flash every 10 seconds when on backup battery power. A red LED will flash to indicate that carbon monoxide has been detected until the device is reset or CO is eliminated or will flash to indicate low battery or alarm malfunction. The unit shall at a minimum meet the requirements of CAN/CSA 6.19-01. It shall also include a 10-year manufacturer's limited warranty or

Test/Reset Button - Tests the unit for proper operation. Resets the carbon monoxide alarm.
• Tamper Resist Feature - If activated, unit goes into constant alarm mode if it has been unplugged or has come loose from the outlet.

Sep 20, 2011 | Kidde Nighthawk Combo Gas/co Detector

1 Answer

My carbon monoxide alarm is beeping this has never happened before...what should I do? The red light is flashing...Had work done on my heating unit earlier today.


Your description sounds like the main alarm is not activated - good, the beeping and flashing light may be that the AC supply is switched off or the internal battery is needing replaced.

The AC supply may have been disturbed with the earlier work.

If in any doubt , do not operate the heating unit until your alarm is working happily.

Feb 13, 2011 | Kidde Nighthawk Combo Gas/co Detector

1 Answer

I have the Caddx NX-6 alarm system. Problem: Alarm system will not arm when entering the 4 digit code. Symptom: I have all doors/windows/zones closed. LED displays READY. I press the code and get 3...


If the power was out for 5 hours and the control panel still shows 'low battery', it's probably time to replace the battery for the control panel. However, this shouldn't keep the alarm panel from arming up. I would first try to re-start the control panel by removing the power and battery connection for a few seconds and plugging it back in. After that, it would be a good idea to re-enroll all of your attached sensors, etc. by entering into programming mode and exiting. Press * 8 + {go code} then just press exit. The default 'go' code is 9713. After about 15 seconds, the panel will have auto-enrolled each attached device. Try arming and disarming the panel. Be careful of setting off the alarm, as your monitoring station may dispatch police, etc. in the event of alarm. This is why having a certified alarm installer do this work is a good idea, as they can put your account with the monitoring station on 'test' so alarm signals are recorded for testing purposes but are not acted upon.

Feb 11, 2011 | GE / Caddx NX 6 Fastpack with NX 1308E LED...

1 Answer

Code 266 and 263, alarm sounding


This is urgent to check immediately - From what I can tell in the manual you are having high levels of CO detected. This is the parts per million reading in your home. See page 6-3 in manual - this the link - -
http://www.detectorsandalarms.com/images/pdf/Manual_KN-COEG-3_900-0113en.pdf


On page 4-2 it says:
If the alarm sounds for carbon monoxide:
1) Operate test/reset button;
2) Call your emergency services ( fire dept. or 911);
3) Immediately move to fresh air - outdoors or by an open
door/window. Do a head count to check that all persons are accounted for. Do not reenter the premises nor
move away from the open door/window until the emergency services responders have arrived, the premises
have been aired out, and your CO and Gas alarm remains in its normal condition.
4) After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps 1-3 and call a qualified
technician to investigate for sources of CO from fuel burning equipment and appliances, and inspect for
proper operation of this equipment. If
problems are identified during this inspection
have the equipment serviced immediately.
Note any combustion equipment not inspected by the technician and consult the manufacturer's instructions,
or contact the manufacturer's directly, for more information about CO safety and this equipment. Make sure
that motor vehicles are not, and have not been, operating in an attached garage or adjacent to the residence.
! WARNING:
Actuation of your CO and Gas alarm indicates the presence of
Carbon Monoxide (CO) or explosive Gas which can KILL YOU.
PHONE NUMBER
PHONE NUMBER
When the CO and Gas alarm senses a dangerous level of CO, the unit will emit a loud alarm pattern and display the concentration
of CO in parts per million (PPM). The alarm pattern is 4 short beeps - followed by 5 seconds of silence - followed by 4 short
beeps repeating. (Note: When the unit is disconnected from the 120V power supply and is on battery backup, the alarm pattern will
continue for the first 4 minutes after detecting CO and then the cycle will repeat every one minute). Know how to respond to a CO
or Gas emergency. Periodically review this user's guide and discuss with all members of your family.
4-

Oct 03, 2010 | Kidde Nighthawk Combo Gas/co Detector

1 Answer

Turn off daily alarms


Sounds like a trouble alarm. Try this manual page 39. Hopefully this is the type panel you have if not let me know of any writing, model numbers etc that could help me identify the specific panel.

http://www.gesecurity.com/portal/GESDownload?ID=4261&DID=4251&documenttype=User Manual

May 24, 2010 | GE Security Simon 3 Wireless Home Security...

1 Answer

Ge simon 2 alarm no longer beeps after battery replaced


Probably knocked off the clip on the piezo. Open the box and make sure all plugs are plugged into the circuit board.

AlarmProfessor.net

May 20, 2010 | GE Security Simon 3 Wireless Home Security...

1 Answer

Low Battery warning on Simon 3 even when I changed it out


temperature affects batteries. if the batteries on the window sensors have been in use for some time it is probably time to change them. Alarm batteries are only expected to last 3 to 5 years with moderate use. If you have close neighbors or live in an apartment complex then false reads could be a factor.

Aug 11, 2009 | GE Security Simon 3 Wireless Home Security...

4 Answers

Nighthawk carbon monoxide alarm model kn-copp-b


Here is a link to the manual, or you can call the consumer hotline at 1-800-880-6788

Nov 10, 2008 | Kidde Nighthawk Combo Gas/co Detector

Not finding what you are looking for?
Kidde Nighthawk Combo Gas/co Detector Logo

536 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kidde Home Security Experts

yadayada
yadayada

Level 3 Expert

63242 Answers

Brad Brown

Level 3 Expert

13732 Answers

 Mikey
Mikey

Level 3 Expert

4994 Answers

Are you a Kidde Home Security Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides