1 Answer

Unit runs gets only to 62 degrees. Top exhaust clean. 5 yrs old

I have had the unit for almost 5 years. Now runs all the time and only reaches 62 degrees. Top mount, top venting unit. Can't find anyone to even look at the thing. Know if a shot of coolant (freon?) will help, or should I just pony up and buy a new unit.

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Teacher:

    An expert who has written 2 tips or uploaded 1 video tip.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 50 Answers

CONTACT THE MANUFACTURER BREEZAIRE 858-566-7473 THEY WILL CONECT YOU WITH A DEALER THAT STILL MODIFIES UNIT TOP VENT.
BREEZAIRE DOES NOT MODIFY THE UNIT TOP VENT THEM SELF NOR DO THEY SELL DIRECT BUT THEY WILL PUT YOU IN CONTACT WITH THEIR DEALER THAT DOES.

Posted on Sep 16, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

CWC-1600 cools constantly


More than likely, the thermostat on the unit is going bad. If the coils haven't been cleaned recently, then I suggest that you unplug the unit, clean it well and then cycle it back on. If it continues, then the thermostat that's located within the unit is going bad. Please refer to the owners manual for proper service and maintenance for your unit. https://www.appliancefactoryparts.com/content/pdfs/140265-1.pdf

Feb 04, 2017 | Heating & Cooling

2 Answers

My dehumidifier runs like a champ, but doesn't put water in the tank, it's been empty for a week or better. The coils don't get cold. Should they? This unit is 5-6 yrs. old. Do I need a new...


Mike, there are 5 things that could be causing the problem you're having. So, before you ruch out to buy a new one, try troubleshooting this one first.

Turn the unit OFF & unplug it before attempting any troubleshooting


1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If you have an analog unit, set
the humidity extraction level knob on Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.


If none of the above solved the problem, it ma be time to start shopping for a new dehumidifier. As repairs can often cost almost as much as a new unit.

Aug 08, 2011 | Fedders A7DH45B2A Dehumidifier

1 Answer

My lg dehumidifier 3 yrs old acts like it is running normally but does not extract any water from the basement air. what can i do?


There are 5 basic, but solvable reason for what you described. Please pay particular attention to numbers 1, 2 & 5.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope this has helped you troubleshoot and solve the problem. Thanks for choosing FixYa.

Jul 23, 2011 | LG LHD45EL Dehumidifier

1 Answer

Re: LHD45EL,...........fan runs but unit will not pull moisture out of the air,..........not a drop. Unit is approx. 2/3 yrs. old. Rather frustrating considering what I paid for the thing originally....


Ken, there are 5 basic, but solvable reason for what you described. Please pay close attention to numbers 1 & 2..

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen. Keep in mind, routine maintenance is the key to any appliance's longevity.

Hope this helped you to troubleshoot and solve the problem.

Jul 13, 2011 | LG LHD45EL Dehumidifier

1 Answer

Fan running..just not dehumidifying all of a sudden...Maytag+45-Pint+Dehumidifier+M7DH45B2 7 yrs old


Todd, there are 5 basic, yet solvable reason for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If you have a manually
controlled model, set the humidity extraction level on Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications . Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity connenser sensor has failed. These things usually occur in units that are 5 years old or older.

I hope this helps you to troubleshoot and solve the problem.

Jul 09, 2011 | Maytag Dehumidifiers

1 Answer

Bucket not filling - ice forming on lid.


You've developed a sealed system problem.

Apr 07, 2010 | LG LHD45EL Dehumidifier

1 Answer

I have to play with thermostat to get my heating system on


You did not make it clear if the thermostat is a programmable unit or not. I am wondering if the thermostat is not set on the correct heat anticipation setting. A heat anticipater is a small heater that helps the thermostat turn off before it over shoots the desired temperature setting. If the thermostat is set for a 5 degree setting, it will turn off at 63 degrees if set at 68. If the anticipater was set at 1 or 2 degrees, it will shut off the heater at 66 or 67. Newer thermostats will only allow the thermostat to cycle 6 times per hour so if you never reach the desired temp, you have to wait 10 minutes before it will allow a call for heat. Check the installation instructions to see if there is a setting where you can get the anticipator temperature closer to your set temp. Good luck.

Dec 11, 2009 | Goodman Heating & Cooling

1 Answer

Have Rheem 5 ton heat pump with stacked coils poor cool.


If your sure on the psi your low on freon or your evaporator is restricted discharge psi would realy help.you will get best performance with a clean unit or pay expensive utility bill . Tom

Jun 18, 2009 | Ruud Central System Air Conditioner

1 Answer

Lg lhd65el dehumidifier icing up


This will need to be serviced. LG has a 5 year warranty on these models. They usually will tell you of a service center nearby which will service it free of charge since it is under warranty. If you do not live near a service center they may ship you a replacement and you send your old dehumidifier back to them. Make sure you have your reciept when you contact them so they can verify it is 2 years old.

Jul 28, 2008 | LG LD65EL Dehumidifier

1 Answer

Ge wall unit cools and then stops


Weather below 50 deg F can harm airconditioners if you run them. If the unit is turned off, then the weather can get as cold as it wants to and not damage the unit. Also 99.999% of the time repair costs on wall units surpass the cost of replacing the unit. This is even accounting for the fact that you will have to pay $25 to $50 to get rid of the old a/c. 5 yrs isn't that bad for a wall shaker anymore. Suggest looking for a new unit.

Jun 27, 2008 | GE AJCQ08ACB Air Conditioner

Not finding what you are looking for?
Breezaire WKCE 2200 Wine Cooler Logo

Related Topics:

278 people viewed this question

Ask a Question

Usually answered in minutes!

Top Breezaire Refrigerators Experts

mike cooper

Level 3 Expert

884 Answers

yadayada
yadayada

Level 3 Expert

76164 Answers

maniman

Level 2 Expert

73 Answers

Are you a Breezaire Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...