Question about Craftsman Welding Tools

Open Question

Welder to generator 3 prong to locking 4 prong 220

Posted by on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 958 Answers

SOURCE: Run ac off of generator.

you need to use a volt meter and test which lead from the 4 wire output of the generator a 220 v is coming out.

the round center prong of the ac is its ground and should not be connected to any live power. it could be left unused.

tnx 4 using fixya,

drcool


Posted on Sep 27, 2008

centurion_BB
  • 83 Answers

SOURCE: Operation of a Devilbiss GT5000 generator

not to familiar with the generators however , I do know that the old style receptacle for 240 volts was three prong. Then OSHA got a hold of it and added a second ground to make it 4 prong, Thats why some houses use a 3 prong dryer cord and some use a 4 prong. hope this helps. and if it has 2 240v outputs BONUS they dont make em like they used to.

Posted on Aug 13, 2009

Testimonial: "Thank you for the answer. Electrical stuff is my weak link. If you need to know anything about investing in the markets I'll return the favor."

  • 1 Answer

SOURCE: I have this Miller

go to the miller website and download the manual. the scematic is in the manual

Posted on Mar 29, 2011

oldTech2332
  • 2341 Answers

SOURCE: I am trying to change my miller welder 4 prong plug to qa 3 prong to match my dryer outlet ? which wire goes where ?

On 4 wire outlets the neutral and ground wire were seperate on 3 wire the ground and neutral are combined so hook up the 2 hots (black&red) as before on the 2 outside terminals and combine the green and white together onto the center terminal

Posted on Nov 12, 2011

  • 17 Answers

SOURCE: generator 4 prong220v outlet to 3 prong 220v plug

Go to your electricians store and ask if they have a converter plug, Don't go to a Homedepot type place, go to the specialty place where electricians go. Their depth of knowledge is way better.

Posted on Jul 13, 2012

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Manuals free


Your question was worded poorly and it's difficult to understand what you are asking. As a guess, if you are looking for a 30-amp adaptor cord set, perhpas this will work:
Conntek 20601 25 Foot 10 4 30 Amp 125 250 Volt 4 Prong L14 30 Transfer...

If it's a 3-prong adaptor:
Camco 55333 30 AMP 3 Prong Generator Adapter

Or a 15 to 20 adaptor:
Coleman Cable 09020 12 3 9 Inch Generator Cord Adapter 5 15P to L5 20R

Aug 27, 2014 | Electrical Supplies

1 Answer

How to connect welder to a portable generator


There are many adaptors , form generator to other connectors, go to Ebay find out which one you need, most hardware stores have converter cables from generator to what you need, most adapters covert 240 to 120v 30 amp or 15 amp or 30amp to 50amp!

Apr 07, 2017 | Diesel Miller 907218 Trailblazer 302...

1 Answer

Generator 4 prong220v outlet to 3 prong 220v plug


Go to your electricians store and ask if they have a converter plug, Don't go to a Homedepot type place, go to the specialty place where electricians go. Their depth of knowledge is way better.

Jul 13, 2012 | Electrical Supplies

1 Answer

Make extension 220 volt cord for 220 volt welder


most 220v welders have a NEMA 10-50 plug or the NEMA 6-50 plug--the input /output ratings thru recepticle and thru plug are same-configuration of plug prongs are different( Grainger Catalogue shows simularities and differences) main difference is AC Horsepower Ratings are different, and that applies Only on equipment that uses 3 phase, not your welder.Use an Ohmmeter to touch unpowered wire connection under shroud at ground and plug prong, then red power connection to corresponding plug prong, and again to black connection and plug prong,mark them w/ felt pen w/ corresponding colors (Green, Black Red). Change out wire plug to fit into dryer or stove recepticle, or make an extention adapter plug witch fits stove recepticle and extends out thru floor to carport and goes to 10-50 recepticle-whereas ground green goes to W position (Center) Y is Black and goes to Y Black, X is Red and goes to X red and cap off the white neutral coming from plug -welders and hot water tanks do not return unused electrcity via the white neutral (return) wire--they use up what is available on demand in heating elements or in welders - the electromagnetic field.GET HELP DOING THIS, by someone who has knowledge, SKILLS and EXPERIECE. I have 1 welder fitted to go into dryer plug which has 14-30 recepticle, and i have 1 where i kill stove circuit at panel, unplug stove, plug in 14-50 plug which has a 10-50 recepticle on other end, plug in welder 10-50 -p, flip cicuit breaker switch to on-welder has full power range capacity. No oven in use while welder going--but probably wouldnt run it anyway if on different circuit.Any doubts whatsoever--anything not 100% clear--DO NOT DO THIS or any other Electrical Manipulations--have a licensed electrician stub in a secondary circuit breaker off your main if load is acceptible and have him wire in the recepticle which your plug will fit into---.

May 31, 2012 | Craftsman Welding Tools

1 Answer

I want to power my weld machine with the generator using a 220V extension cord that Im gonna make myself. Though the gen. has a 4 plug twist female and the weld machine is a 3 prong push male. What to do?...


I don't recommend you do this, you will dmage the generator as the alternator is not big enough to handle a large inductive load. To specific answer your question, your welder has a 3 prong, L1 L2 and ground, feeding a transformer, your generator has L1 L2 N + Ground. Again I don't recommend you wire this

Aug 15, 2011 | Coleman Powermate Premium Plus 6250W...

1 Answer

I have an opportunity to purchase a used powermate maxa 5000 er and a used transfer switch that it was used with. it is a 6 circuit type box. i was suprised to see that the generator was old enough that it...


Hi,
There is no reason not to use the plug... it may vibrate out though...that's what duct tape is for...:-)

The electrician should hook it up,, I would no problem...those tranfers are apiece o cake....
I say go fer it...

heatman101

Aug 29, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

I have a Hobart Champion 10,000 welder generator. It runs but I am getting no juice out of it. Won't weld or put out power to run anything.


measure ouput on ALL available sockets - anything?
Take cover off electric motor-generator, visually inspect windings.
Measure continuity of all stator windings (2 or 3 points usually)
Measure continuity of stator thru brushset.
If all measures ok - has to be AVR module.

There is no mistery in generator - just stator to induce and rotor to obtain voltage.

Jan 01, 2010 | Hobart Champion 10,000 All-in-One...

1 Answer

Operation of a Devilbiss GT5000 generator


not to familiar with the generators however , I do know that the old style receptacle for 240 volts was three prong. Then OSHA got a hold of it and added a second ground to make it 4 prong, Thats why some houses use a 3 prong dryer cord and some use a 4 prong. hope this helps. and if it has 2 240v outputs BONUS they dont make em like they used to.

Aug 13, 2009 | Electrical Supplies

1 Answer

Run ac off of generator.


you need to use a volt meter and test which lead from the 4 wire output of the generator a 220 v is coming out.

the round center prong of the ac is its ground and should not be connected to any live power. it could be left unused.

tnx 4 using fixya,

drcool


Sep 27, 2008 | Hampton Bay HBLG5004 Air Conditioner

Not finding what you are looking for?
Welding Tools Logo

Related Topics:

57 people viewed this question

Ask a Question

Usually answered in minutes!

Top Craftsman Welding Tools Experts

yadayada
yadayada

Level 3 Expert

74945 Answers

wadingriver
wadingriver

Level 3 Expert

2069 Answers

L Pfaff
L Pfaff

Level 3 Expert

11573 Answers

Are you a Craftsman Welding Tool Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides