HAIER hbf05ebss beer dispenser compressor not starting

My HAIER hbf05ebss beer dispenser just broke. The compressor is hot and does not start. This happened to my kitchen fridge a year ago and the technician said the compressor and motor must have broke but he did not use any tools to prove this. So I just replaced the control board myself and it worked fine. So I am wondering maybe the same type of issue.
So I would like to know where to get the parts diagram and parts list for hbf05ebss. I would like to know if there is a control panel which controls the relay, motor, and compressor and which other parts may be defective. What is part number for relay, control board, and other components which start the compressor? I really doubt the compressor is bad.

Posted by on

  • karlgundal Jun 05, 2010

    I took out the start relay and measured resistance and it was open circuit. It is supposed to be 0 ohms at room temp. Just ordered part....hopefully fixes issue.....

×

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

heatman101
  • 43501 Answers

SOURCE: my haier beer dispenser model HBF05EBSS will not

Hi,
Try to change the capacitor and start relay first...then maybe if that don't work the compressor...

Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";} Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay


heatman101


Posted on Aug 31, 2010

  • 488 Answers

SOURCE: my haier beer dispenser model HBF05EBSS will not

Just In case You want to see how to replace compressor on refrigerator, I made video. Check it out. REPLACING COMPRESSOR TRUE AIR BEER COOLER R134A

Posted on Feb 04, 2015

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Plugged it in it worked great for the first few hours, but then it didnt stay cold. kept on about week, stayed spotty, getting cold, and not. im broke, need to fix'r myself, i just dont know how.


Do you know how to jump the thermostat wires? The problem could be the start relay, thermostat or a Freon leak. Does the compressor get hot while running? Does the compressor stop and start frequently?
APPLIANCE 911

Jun 04, 2016 | Haier Refrigerators

1 Answer

Not starting


ck that you are getting power to it some of them have fuses on them , the switch may be bad

Mar 28, 2014 | Haier Kegerator HBF05EBSS Draft Beer Tap...

1 Answer

I have a kegerator. It's not functioning. When plugged in no clicking no sound nothing. Wondering if it's the overload switch or relay.


http://www.haieramerica.com/en/asset/product/1ffd77cfa0
This site has your product manual for your dispenser but it is very vague on trouble shooting the cooling system.
In general, the compressor is controlled by a thermostat that is usually located in the conditioned space. It cycles the compressor on and off based on the sensed temperature and the setting that it is adjusted to.
So, let's talk in general refrigeration terms. Where the compressor is located, is there a fan? If so, is it running? That fan is usually the condenser fan and is wired to come on anytime the compressor is supposed to be running. If the fan is running and the compressor is not, then there is an issue with the compressor. If the fan is not running and the compressor is not running, then there is an issue with either power or the thermostat. If the compressor is running and the fan is not, then there is an issue with the fan.
This is a good starting point. Let me know if I can be of further help.

Mar 24, 2011 | Haier HBF05EBSS Commercial Beverage...

1 Answer

I have a 2 year old Haier kegerator and it seems to have stopped working. I hear a clicking sound which I believe is the compressor going on and off. I have done some research and found that this is a...


Do you have any technical background? There is a simple and sure fix to this but you will need to be able to read a wiring diagram and have basic electrical tools like a wire stripper and electrical tape.

Dec 02, 2010 | Haier HBF05EBSS Commercial Beverage...

2 Answers

My haier beer dispenser model HBF05EBSS will not turn on. Compressor is hot and keeps clicking on and off. How can I fix


Hi,
Try to change the capacitor and start relay first...then maybe if that don't work the compressor...

Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";} Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay


heatman101


Aug 31, 2010 | Haier (HBF05EAVS) Beverage Dispenser

1 Answer

When plugged in, the compressor never kicks on. It just clicks.


If the compressor is getting hot then the compressor is gone. But the price on a relay is fairly cheap so you can at least try it and if it doesnt work then return it and dump the unit. But like I said before when a compressor gets hot it means that the piston is bad and the rings are burnt and the oil is bad in the compressor.

Feb 13, 2009 | Haier HBF05EBSS Commercial Beverage...

1 Answer

Can I replace a damaged evaporator coil?


Well, the old screwdriver through the evap trick huh?. you planned on repling evap coil and recharging with 134 a? correct??if you have that knowledge and ability then installing a charging port would be least of issue. sorry for sarcasm but not a do-it-yourself fix honestly bring it down to a local repair guy

Feb 29, 2008 | Haier HBF05EBSS Commercial Beverage...

1 Answer

Beer dispenser


Shut of the CO2 tank, then hit the pressure release valve on the side of the beer tap. Make sure there is a grey check valve in the tap where the red hose (co2) is connected. Also make sure the white ball in the tap where the white hose (beer line) is not stuck. You can remove this, it isnt really necessary. Once all checks out, open the tank and readjust the co2 regulator. The reading should not be more than 12 PSI. Everything should work just fine after this. Make sure the glass is as close to the faucet as possible (slanted is better) when dispensing beer. Hope this help :)

Jan 21, 2008 | Haier (HBF05EAVS) Beverage Dispenser

2 Answers

Haier beer dispenser model HBF05E


Either its not getting cold enough to shut off or your thermostate isnt working.. thats the only thing that cycles it.

Aug 27, 2007 | Haier (HBF05EAVS) Beverage Dispenser

Not finding what you are looking for?
Haier HBF05EABB Beer Despenser Logo

Related Topics:

130 people viewed this question

Ask a Question

Usually answered in minutes!

Top Haier Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4654 Answers

doggzzz

Level 1 Expert

14 Answers

Brad Brown

Level 3 Expert

15441 Answers

Are you a Haier Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...