I have the same compressor with the same problem. I have temporarily eliminated the thermal reset with a piece of 12 gauge hard wire and it runs just fine. However, I do want to replace it before the warm weather come to the north. I tested the draw at 15.5 amps and the reset was a 17 amp. I am told by someone with superior electrical background that I need to install a 20 amp thermal reset in it's place. I have found that mine runs best when plugged directly into a 20 amp circuit and when using an extention cord I have a 10 guage cord that will carry the load needed to run the EC12.