ANGIE MASSIE Posted on Mar 31, 2008

I HAD AN ICE BALL PROBLEM IN THE LOWER RIGHT SIDE OF MY REFRIGERATOR IN WHICH THEY CAME AND FIXED BY INSTALLING A HEATER. bUT NOW I HAVE ICE BUILD UP IN THE NEXT SECTION UP IN THE FRIDGE WHAT WOULD BE CAUSING THIS?

  • 1 more comment 
  • ANGIE MASSIE Apr 01, 2008

    GE pss26pswass side by side refrigerator

  • deoncollins6 Feb 19, 2009

    This is a common issue. Ge will replace your fridge if it is under warranty They did with me. I would bug the **** out of them. It will never stop!! They installed a heater kit in mine and it slowed it down to just condensation. Call GE and Complain

  • Anonymous May 11, 2010

    What brand of refrigerator is it. Also, the model will help to offer tips.

×

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 26 Answers
  • Posted on Apr 01, 2008
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Mar 31, 2008
Answers
26
Questions
0
Helped
23130
Points
77

Some how warm ambient temps are finding their way in there and causing this ice up. I do know that samsung had built a few of the ge models which have evaporator coils in the refrig section. You should shut off the refrig completely and leave the freezer door closed, but open up the refrig door and let it defrost down to room temp. After trying this log how many days it takes to come back and if its in the same area.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

We have a GE GSS25QGTA CC side by side and the icemaker stopped working. The water still dispenses on the door without a problem. There is ice build up behind the ice cube container. Iuse a blow dryer to...

look for a reason that the ice is building up . it sounds like a defrost problem and the coil is being blocked with ice . this is caused by the defrost cycle not working . it may have a bad defrost heater of timer . either could cause this.. do ck the tempt in freezer if must be 15 deg or lower for ice mker to work . . mm feed back [pls )
1helpful
1answer

My ge side-by-side refrigerator/freezer isn't cooling. It started on the refrigerator side and now both sides are losing cooling capability. There is ice build up on the lower back wall of the freezer....

Yes that is right. Turn the Refrigerator off/ unplug it. Remove the rear panel of the freezer and thaw out the coils with a fan or hair dryer.

The most common problem is with the defrost heater. Using an ohm meter check the heater for continuity but unplug the 2 wires (one from each side). This should be a glass encased heater. you can also very gently pull both ends of the heater and if it is bad it will come apart instead of feeling "springy". If you have only one heater your new replacement will probably be a 2 heater kit.

I
0helpful
1answer

We have replaced our G.E. side by side refrigerator mother board ,it did fix the problem with the ice maker and water not working ,a week later ,the ice started to build up agian and fridge is not getting...

The bdefrost heater behind the wall inside the freezer is bad if the ice you have is on the back wall of the freezer. Remove the back wall and deice the coils and replace heater. wr51x10101
0helpful
2answers

Ice build-up in lower freezer. We replaces the

warm between doors is normal. if hot then clean coils and if coils clean make sure condenser fan motor working thats the fan in the back compartment, however if warm thats good. did the evaporator coil freeze from top to btm is that why u replaced heater. if it was then could be heater,if the coil is only getting frost on half the coil,you could have a sealed system problem. is the evaporator motor working in the frz side if not,then that could be the problem.if coil is froze up it needs to be defrosted. did you defrost coil when you replaced heater,if not try defrosting coils and then wait about 12 hrs and see how it does.
0helpful
1answer

Ice Building UP in freezer GE SIDE BY SIDE

Check if the door is sealing properly.and the door gaasket is fixing correctly.Especially check same direction at the door which ice is accumulated in the compartment.
1helpful
1answer

Ice building up in freezer

Due to the frosting up, The glass defrost heater broke. Any good tech knows this happens. The defrost heater must be replaced. If this is a GE side by side. The new replacement heater has dual elements. The standard heater that was put in them, was not large enough to defrost the coils fully. Replace heater and you should be fixed up. I would also replace the thermostat while you are in the freezer section they are only like 15 bucks and this way you will have a new defrost circuit.
0helpful
1answer

Ice build up in the fridge

you have a problem with your defrost system, unplug appliance - remove panel from back of freezer, test defrost heater, if heater good test defrost thermostat - replace bad part....if this is too technical call a repair guy...should cost between $120 - $200 to fix depending on which part is bad.
1helpful
1answer

Side by side Maytag frig that is warm on top, not bottom

You can turn the thermostat off for now to let the ice thaw out, if a door was left open there might not be anything wrong, but if it freezes up again sounds like you might have a bad defrost heater or defrost limit. Hope this helps
0helpful
1answer

Ice keeps building up on coils

We had the same problem with our GE frig, a Profile 24. When the tech came out, he explained that the energy efficient models have only 1 defrost heater, but the older units had 2 and the hook up and mounting positions were still there. As long as I directed him to install the 2nd heater he could do it. It turned out the original heater was just fine, so the replacement was installed in the 2nd heater space and it has worked fine for several years now. Before doing this on yours, I would verify that the defrost timer is working and the heater unit is ok.
0helpful
1answer

Fridge freezing

a defrost problem, is gonna cause excessive ice build up in hte frezzer lower compartment. for somereaon the hdefrost heater was not energized. most common reason is a bad defrost thermostat, clipped on one of hte evaporator coils has gone bad,
Not finding what you are looking for?

276 views

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...