Question about Crown XTi 2000 2-Channel Amplifier

1 Answer

XTi 2000 2-Channel Amplifier: when power is switch on amp don't play i have to t...

When power is switch on amp don't play i have to tap the front for it to play what's the problem.

Posted by Anonymous on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Crown Master
  • 5,056 Answers

A loose wire or bad solder connection.

Posted on May 16, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I use the crown xti 6000 for 2 double 18s pd186 for bass per channel


Send a signal from the mixer to the amp directly, seems as if you have a distorted signal from your crossover

Dec 23, 2013 | Crown XTi 2000 2-Channel Amplifier

1 Answer

Does the input signal to the xti 2002 amp make adifferance balanced or un?


The balanced line input will be used for long runs to eliminate noise. it is low impedance.the high impedance line (unbalanced) is ok for sort runs such as in a rack. if you were say running output from a mixer 50' away you want to use the balaced output on the board and the balanced input on the amp.

Aug 31, 2011 | Crown XTi 2000 2-Channel Amplifier

1 Answer

I have an elderly (but until now totally reliable) SA-620 amplifier. All of a sudden the left channel isn't working. It is the same whether you use the A or B outlets. Any ideas as to how I can fix this?


You do not mention whether you use one or several inputs on the SA620, but move the selector switch to & fro a few times to clean its contacts. Similarly, unpIug the phono plugs & replug (on Left channel). I aIso assume there is no left channel when using headphones. Also check the two thick wire links at the back are pushed in properly (take out & push back in to make sure), since these link the preamp to the power amp. All the above is done with mains power off.

On these old units, switches sometimes fail due to impurities on their contacts, so operate them all (with mains OFF) a few times to wipe the contacts clean.

It would be informative to find out if the fault is in the preamp or power amplifier section.
To do this, connect signal (eg external CD) to the TAPE 1 'PLAY' input (left) & switch front panel to TAPE 1. This bypasses the preamp section & injects the signal into the volume control. If there is still no left- hand channel, then the fault is likely to be in the power amplifier.


Only if you are technically competent, disconnect SA620 from mains, remove the SA620 lid, and with an insulated object eg a plastic screwdriver handle, tap the loudspeaker relay RL1 to release a possible sticking contact. If this does not cure the fault, then the same can be done with the unit turned on & a signal present.

If there is still no response, further fault finding in the power amp will be req'd.

Feb 12, 2011 | Pioneer Audio Players & Recorders

1 Answer

How do I unlock my XTi 2000 amp?


Pressing & holding the prev/up & next/down buttons at the same time will toggle the lock on or off.

Mar 12, 2010 | Crown XTi 2000 2-Channel Amplifier

1 Answer

I have my amplifier connected to my dj system only one speaker of the bass works wich is channel 1 channel 2 does not work and fault button keeps on blinking red?


The XTI 2k has lots of DSP options built into the front panel. If it's your intent to run the amp in bridge mono for subs be sure than you have all settings set correct for the DSP, it's very possible that channel 2 will render in-active.

This also applies in the case if you wanted to run your subs in stereo and the internal settings are set for bridged mono.

Another possibility would be if the DSP was set with a crossover. If you put a cross-over point (Low Pass Filter) on the high side of the sub, if becomes the High Pass Filter of Channel 2. Audio would pass if there was no other filter sets, but would not if you were using a crossover and then hitting the subs.

Sep 11, 2009 | Crown XTi 2000 2-Channel Amplifier

1 Answer

My XTi 2000 is very distorted intermintently. Sometimes the volume drops by at least half. I tap gently on he top of the amp and it comes back up to normal. I heard Crown has had some issues. What's the...


From your description, I would suspect some poor solder connections inside. If you know how to work on these, check for bad connections near the voltage regulators. That is the mode common area.

Dan

Jun 30, 2009 | Crown XTi 2000 2-Channel Amplifier

1 Answer

I need the schematic for the crown amplifier xti 1000 crown xti 1000 2-channel amplifier


These are available for purchase from Crown. Generally they are not available on the web. Is there a specific problem that you are having?

Dan

Jun 28, 2009 | Crown XTi 2000 2-Channel Amplifier

1 Answer

Keep blowing speakers


It sounds more like you are overdriving the speakers not clipping the amp. If the output rating for the amp is 1000W into 4 ohms, this is approximately 500W into an 8 ohm load. Your speakers are rated for 400W. If you are running the amp at full output, that is too much power for the speakers and either the speakers are warming up too much and failing or are being extruded too far and failing. Your best bet is to better match the amp/speaker setup. Crown amps have built in clipping indicators and I believe that the xti series also has a compression circuit that would prevent distortion on the output side.

To confirm my suspicions, in what manner are the speakers failing? Are they completely open or do they sound distorted?

Thanks,
Dan

Apr 22, 2009 | Crown XTi 2000 2-Channel Amplifier

1 Answer

I have two xti 2000 amp running with electrovoice speaker 600w


This is most likely to be a heat issue where the amps overheat and shut themselves off then cool down and turn back on. Please check that the amps have proper ventilation and that any air ducts are clean.

Feb 26, 2009 | Crown XTi 2000 2-Channel Amplifier

2 Answers

Amp cuts off


The amplifier is going into protection. This may be caused by problems with speakers or wiring, or there may be internal problems in the amplifier. Start by connecting a known good speaker with a few feet of wire, and see if it runs without shutting down. If so, check the wiring and speakers. If the problem continues, the amp should be serviced.

Nov 23, 2008 | Crown XTi 2000 2-Channel Amplifier

Not finding what you are looking for?
Crown XTi 2000 2-Channel Amplifier Logo

Related Topics:

282 people viewed this question

Ask a Question

Usually answered in minutes!

Top Crown Audio Players & Recorders Experts

 Grubhead
Grubhead

Level 3 Expert

5056 Answers

The Knight
The Knight

Level 3 Expert

74136 Answers

Paul Bade

Level 3 Expert

1536 Answers

Are you a Crown Audio Player and Recorder Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...