Question about Panasonic Cameras

2 Answers

I want a Main PCB of GS-57GC Part code is LSEP8331S1

Posted by on

  • mishramba May 14, 2010

    Dear Sir
    I am Umesh Chandra Mishra From India.
    Basicly i am a services Engineer of electronic product
    at present i require a main pcb of Panasonic Camera GS57GC
    part code is LSEP8331s1
    I already enuire from panasonic india
    but they dont have So please give me a solution
    Thanks & Regards
    Umesh Chandra Mishra
    +919425092184

×

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Panasonic Master
  • 19,396 Answers

Hi.

LSEP8331S1 is not the main PCB, but the camera PCB. This camera has two PCBs.

The camera PCB is not available for online purchase.

Here the parts number applying to your model. None of them is available for online purchase.

LSEP8331P1/ LSEP8331Q1/ LSEP8331R1/ LSEP8331S1

Here the number for main PCB
LSEP8330P1

Both boards can be ordered from Panasonic

Here the service manual, check page 96-98 for parts numbers.

When you are sure about the part you want replace use google to find a seller in your area.

Here a distributor with main pcb for your model:

UED.net Catalog



Posted on May 14, 2010

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Panasonic Master
  • 13,433 Answers

Please contact Panasonic parts center http://www.pasc.panasonic.com/ National Parts Center at 800-833-9626.

Posted on May 14, 2010

  • 2 more comments 
  • mishramba May 14, 2010

    Dear Sir

    I am from India & i want this in INDIA

    you are giving me this address of uk

    please give me a another source not from panasonic co.

    Thanks & Regards

    Umesh Chandra Mishra

    +919425082184

  • Ekse May 14, 2010

    Contact panasonic india, they should direct you to the right location.





    Panasonic India Pvt. Ltd.
    Consumer Sales Division
    No. 88, 6th Floor, “ **** building Annexe”
    Mount Road, Guindy, Chennai – 600032
    Phone: +91-44-22301952/22304100
    Fax: +91-44-22301951

    Customer Care Helpline
    Phone : +91-44-22304153/54
    Toll Free No. : 1860 425 1860
    Email : helpline@npi.panasonic.co.in

  • mishramba May 14, 2010

    Dear Sir

    i want a extra source Except pansonic co.

    I can buy if it is used

    i am a service engineer of panasonic

    Thanks & Regards

  • Ekse May 14, 2010

    part not available outside Panasonic repair facilities, or possibly not available at all. Thank you for using fixya and good luck.

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ir 3300 copier error code e000732-0001


Canon iR3300 Error Codes Code: E732-0001

Code

E732-0001

Description

A fault is detected by the main controller PCB in the communication between reader controller PCB and the main controller PCB

Causes

The connector has poor connection. The reader controller PCB is faulty.

Remedy

1. Connector, Reader controller PCB Is the connection between the connector J1014 on the main controller PCB and the connector J409 on the reader controller PCB normal? NO: Correct the connection. YES: Replace the reader controller PCB.

Below is the site this came from which lists all the error codes in case another occurs after you resolve this one


Canon iR3300 Error Codes List page 1 from 12

Aug 27, 2016 | Canon Ir 3300 Black & White Copier

1 Answer

Image runner getting this error code E261-0000 / how do i fix it


Code

E261-0000

Description

The intervals of zero-cross signals deviate from the tolerance range while the fixing heater is supplied with power

Causes

The wiring is faulty (short circuit, open circuit). The main power supply PCB is faulty. The DC controller PCB is faulty.

Remedy

1. Connectors Are the connector J205 on the main power supply PCB and the connector J308B on the DC controller PCB securely connected? (zero-cross signal: J205-7 <-> J308B-1) NO: Connect the connectors securely. 2. Main power supply PCB, Main controller PCB Try replacing the main power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.

Best Regards

Jul 24, 2016 | Office Equipment & Supplies

1 Answer

Image runner getting this error code (E261-0000) / how do i fix it


Code

E261-0000

Description

The intervals of zero-cross signals deviate from the tolerance range while the fixing heater is supplied with power

Causes

The wiring is faulty (short circuit, open circuit). The main power supply PCB is faulty. The DC controller PCB is faulty.

Remedy

1. Connectors Are the connector J205 on the main power supply PCB and the connector J308B on the DC controller PCB securely connected? (zero-cross signal: J205-7 <-> J308B-1) NO: Connect the connectors securely. 2. Main power supply PCB, Main controller PCB Try replacing the main power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.?

Best Regards

Jul 24, 2016 | Office Equipment & Supplies

1 Answer

The solution for an error code E000733-000


E733
0001 A fault is detected by the main controller PCB in the communication between
the DC controller PCB and the main controller PCB.
Main cause The connector has poor connection. The DC controller PCB is faulty.
Action
1. Connector, DC controller PCB
Is the connection between the connector J1015 on the main controller PCB
and the conductor J316 on the DC controlled PCB normal?
NO: Correct the connection.
YES: Replace the DC controller PCB.

Jun 29, 2014 | Canon imageRUNNER 3225 Black and White...

1 Answer

Canon ir 3300 error code e000803-0000


Similar to Description The 24V output from the composite main power supply PCB is absent for 1 sec or more Causes The wiring is faulty (short circuit, open circuit). The composite power supply PCB is faulty. The DC controller PCB is faulty. Remedy 1. Connectors Are the connectors J204 on the main power supply PCB and the connector J300 on the DC controller PCB connected securely? NO: Connect the connectors securely. 2. Main power supply PCB Is 24 V supplied by the main power supply PCB (J204) to the DC controller PCB (J300)? (J204-5 <-> J300-5: OVU3, J204-6 <-> J300-6: OVU3, J204-7 <-> J300-7: 24VU3, J204-8 <-> J300-8: 24VU3) NO: Replace the main power supply PCB. YES: Replace the DC controller PCB.

Aug 21, 2012 | Canon Ir 3300 Black & White Copier

1 Answer

Error code e000733-0001


E733
0001 A fault is detected by the main controller PCB in the communication between
the DC controller PCB and the main controller PCB.
Main cause The connector has poor connection. The DC controller PCB is faulty.
Action
1. Connector, DC controller PCB
Is the connection between the connector J1015 on the main controller PCB
and the conductor J316 on the DC controlled PCB normal?
NO: Correct the connection.
YES: Replace the DC controller

Jan 23, 2010 | Canon (6981A002AA) for imagerunner 2200,...

1 Answer

E000733-0001 error code


E733 0001 - A fault is detected by the main controller PCB in the communication between the DC controller PCB and the main controller PCB.
Main cause The connector has poor connection. The DC controller PCB is faulty.
Action
1. Connector, DC controller PCB Is the connection between the connector J1015 on the main controller PCB and the conductor J316 on the DC controlled PCB normal?
NO: Correct the connection.
YES: Replace the DC controller PCB

Nov 13, 2009 | Canon imageRUNNER 5000 Copier

1 Answer

Error code E000803-000


that mean low power or The 24V output from the composite main power supply PCB is absent for 1 sec or more.
Main cause The wiring is faulty (short circuit, open circuit). The composite power supply PCB is faulty. The DC controller PCB is faulty.
Making Corrections
1. Connectors
Are the connectors J204 on the main power supply PCB and the connector J300 on the DC controller PCB connected securely?
NO: Connect the connectors securely.
2. Main power supply PCB Is 24 V supplied by the main power supply PCB (J204) to the DC controller
PCB (J300)?
(J204-5 <-> J300-5: OVU3, J204-6 <-> J300-6: OVU3,
J204-7 <-> J300-7: 24VU3, J204-8 <-> J300-8: 24VU3)

Feb 05, 2009 | Canon imageRUNNER 3300 All-In-One Laser...

1 Answer

Hi, i have 2pcs of canon iR2016 Digital copiers which displays error codes of E246 AND E247. these errors are not in the service manual, please help


Sir i am a Canon trained tech. I just checked our website and my service information. I found the following. I suspect someone has been working on these machines or swapped some parts around.

Page 1 of 2
MODELS AFFECTED / SERIAL NUMBERS AFFECTED:
Digital Copiers, Including All imageRUNNER Products
SUBJECT:
Information About The New Soft Counter Circuits
GENERAL TECHNICAL INFORMATION
GENERAL:
This Technical Publication presents information about the new Soft Counter circuit that replaces the mechanical counter
used in the past. There are three (3) PCB’s associated with the new Soft Counter circuit; the Counter Memory PCB,
Main Controller PCB and the Serial Number PCB. A description of their function is provided below. Use this
document as a reference for current and future models that use the Soft Counter circuit.
Counter Memory PCB
On the latest Canon digital copiers, such as the imageRUNNER 5000, imageRUNNER 8500 and imageRUNNER 2200
series, there are no mechanical counters. Instead there is a Counter Memory PCB. This PCB is usually mounted on the
Main Controller PCB with one screw. The Counter Memory PCB is imprinted with the serial number of the machine
the first time power is turned ON and cannot be moved to another machine. Attempting to do so will generate an E246
error code. In the event of a Counter Memory PCB failure, a new one from stock (see Note 4) can be installed into the
machine. At that point the Main Controller PCB will transfer its present total count as indicated in “Counter Check” on
the control panel (recorded the last time power was turned OFF) to the new Counter Memory PCB and the total counter
will increment from that count on. Never attempt to operate a machine without the Counter Memory PCB
installed!
This may generate an E245 code, which can only be cleared by “zeroing out” the Main Controller PCB by
one of our A.P.R.F.’s (Authorized Parts Repair Facilities).
Main Controller PCB
The Main Controller PCB, aside from performing other tasks, retains the total count by means of SRAM with a battery
back up after power has been turned OFF. If, however, the Main Controller PCB has been replaced with either a new
one or a used one, it will read in and record the total count from the Counter Memory PCB retained the last time power
was turned OFF. The total count will then increment from that count on.
Note 1:
Even though the total count will be the correct value for that machine after replacing the Main Controller, the soft
counters in Service Mode will not. If a new Main Controller was used for the replacement, then all soft counters in
Service Mode (service counters in “Counter Mode”) will be zero. If, on the other hand, a used Main Controller was
used for this replacement, the soft counters previously recorded on that PCB would be shown. At that point it is
advisable to clear these values in Service Mode using Function>Clear>CNT-MCON.
All Main Controllers sent to our A.P.R.F.’s for repair will be “zeroed out” before being sent back to the dealer.
Page 2 of 2
GTI-T151
04-30-02 GT I
Note 2:
The Counter Memory PCB and the Main Controller PCB should never be replaced simultaneously!
This will
generate an E354 code and assistance from the Canon Reseller Technical Support Center Hotline will be required. If
the Main Controller is sent to one of our A.P.R.F.’s for repair, you must remove the Counter Memory PCB
before sending it out!
Failure to do so will only increase down time for your customer.
Note 3:
If the Main Controller PCB is replaced, ensure that connector J1023 is connected. If it is not, an E350 will be
generated.
Serial Number PCB
The Serial Number PCB’s main function is to identify the machine’s serial number. This PCB cannot be moved to
another machine.
Attempting to do so will generate an E355 and assistance from the Canon Reseller TechnicalError codes not listed in the Service Manual:
There are various error codes that are not listed in the Service Manual. Canon U.S.A., Inc. reserves the right to treat
these error codes as Proprietary Information. If you encounter any of the following error codes, contact your Canon

E245 E246 E247 E350 E354 E355
Note 4:
Please be advised that Canon U.S.A., Inc. treats the Counter Memory PCB and Serial Number PCB as “restricted” parts.
When a dealer orders these components they will be asked to provide the reason for their replacement, and the original
PCB will have to be returned to Canon U.S.A., Inc. for evaluation.

Jan 07, 2009 | Office Equipment & Supplies

3 Answers

E60 error code


Found These Fault Codes On Internet, Hope This Helps, Daz

ALARM CODES

E00(E00)- Problems with water fill during washing
-Tap closed; solenoid valve, water distributor, wiring ,main PCB, pressure switches

E01(E00)- Problems with water fill during drying
-Tap closed; solenoid valve, wiring , main PCB, pressure switches

E10(E10)- Problems with water drain during washing
-Drain hose kinked, filter blocked, drain pump, water distributor, wiring , main PCB, pressure switches

E11(E10)- Problems with water drain during drying
-Drain hose kinked, filter blocked, drain pump, pressure switches

E20(E20)- Door open
-Cycle in Door delay, wiring , main PCB

E21(E20)- Fault in door delay power triac
-Wiring , main PCB

E30- Fault in electronic pressure switch
-Electronic pressure switch, wiring , main PCB

E31- Fault in electronic pressure switch circuit
-Main PCB (fault in electronic pressure switch circuit)

E32(E10)-Calibration error in electronic pressure switch
-Electronic pressure switch, drain pump, wiring , main PCB, filter blocked

E33- Incongruency between electronic pressure switches and safety switch 1
-Electronic pressure switch, safety pressure switch,wiring, main PCB

E34- Incongruency between electronic pressureswitches and safety switch 2
-Electronic pressure switch, safety pressure switch,wiring, main PCB

E35- Intervention of anti-overflow pressure switch
-Solenoid valve, water distributor, wiring, main PCB,anti-overflow pressure switch

E36- Water leakage (maximum number of resets exceeded)
-Water leakage, drain hose too low, pressure switch,wiring, main PCB

E40- Motor power triac short-circuited
-Main PCB (triac short-circuited)

E41- No signal from tachimetric generator
-Tachimetric generator on motor, wiring, main PCB

E42- Fault in tachimetric generator circuit
-Main PCB (tachimetric generator sensing circuit)

E43- Intervention of motor overload protection
-Motor, wiring, main PCB

E50- Insufficient heating during wash phase
-NTC sensor setting incorrect, heating element, wiring,main PCB

E51- Overheating during wash phase
-Heating element (to earth), main PCB (relays)

E52- Insufficient heating during drying phase
-NTC sensor setting incorrect, safety thermostat,thermostats, drying heater, wiring, main PCB (relays)

E53- Overheating during drying phase
-Drying heater (to earth), main PCB (relays)

E55- Fault in power relay for heating element (K3)
-Safety pressure switch 2, wiring, main PCB- 6 -

E60- Fault in washing NTC sensor
-Washing NTC sensor, wiring, main PCB

E61- Fault in drying NTC sensor(condenser)
-Drying NTC sensor (condenser), wiring, main PCB

E62- Fault in drying NTC sensor(duct)
-Drying NTC sensor (duct), wiring, main PCB

E63- Fault in 1/2 power thermostat
-Drying NTC sensor (duct), 1/2 power thermostat, wiring,main PCB

E70- Power triac to distributor motor short-circuited
-Main PCB (triac short-circuited)

E71- Fault in power relay to distributor loads
-Main PCB (relay open)

E72- No distributor position signal
-Water distributor motor, wiring, main PCB

E73- Incorrect timing on distributor contacts
-Water distributor, wiring, main PCB

E90- Fault in tank fill pump
-Hoses obstructed, tank fill pump, wiring

E91- Fault in tank drain pump
-Hoses obstructed, tank drain pump, wiring

E92- Fault in power triac to tank fill pump
-Tank fill pump, wiring, main PCB

Jan 04, 2008 | Zanussi ZWF1440 Front Load Washer

Not finding what you are looking for?
Cameras Logo

Related Topics:

51 people viewed this question

Ask a Question

Usually answered in minutes!

Top Panasonic Cameras Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

74136 Answers

Computer Links

Level 3 Expert

2385 Answers

Are you a Panasonic Camera Expert? Answer questions, earn points and help others

Answer questions