Question about Frigidaire FAC124 wall/Window Air Conditioner

1 Answer

I am turning on my window air conditioner for the first time since last summer. Air is blowing but water is coming out of the vents as if water is inside.

Posted by Anonymous on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 1,515 Answers

Hi, what is going on is the unit is working good so you will have condensation running down the front of the indoor coil. You will have a trough at the bottom that has collected dirt over the winter and has clogged up the drain. Some window units have a small supple clear hose attached to one end of the coil that may be plugged up, or this unit has what we call weep holes around it starting at the inside edges on each corner and around the out side. Go outdoors and look and see if you see a hose or very small holes that are plugged up. If the hose/if there is one, try and blow it out. What is happening, is the blade from the fan motor is picking up the water and slinging it into the home. Yes, you can solve this once you find how it drains and where it drains. Take a good strong light inside to check the front and see if indeed there is a hose. Keep me posted on this and I hope that I have led you in the right direction to solve this, and I am sure I have. Please let me know.
Sincerely,
Shastalater7

Posted on May 13, 2010

  • Robert Horton
    Robert Horton May 17, 2010

    Hi, just checking back to see if I was of some help to you and to ask for a rating if I was. I hope I was and you will rate me well.
    Sincerely,
    Shastalaker7


×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The air conditioner starts blowing hot air on the driver side while the passenger side blows cold air.


2004 Suburban air conditioner blows hot air to the dirver side but cold air to the passenger. This does not happen all the time but has occurred several times this last summer.

Sep 14, 2010 | 2003 Chevrolet Suburban 1500

2 Answers

Unit lights up and hums but does not blow air


mcdevito75 here, Sounds like the fan motor is haging up or needs to be replaced, try the switch on/off then on/off a few times see if the fan kicks on, if not see your local a/c repair shop, they come to the house.

Jun 22, 2010 | Whirlpool ACQ158XP Wall/Window Air...

1 Answer

Cold air not blowing out evenly across the vent, mediumn cool on


Please check that the directional louvers are not set on one side. Also clean the filter screen in the front. It should be free from dust and pollen. Remove the front cover and switch on the air conditioner. Check the flow of air. If it is one sided then there is problem with your blower. For that you may have to call a technician.

Jun 01, 2010 | Heating & Cooling

2 Answers

Blowing water


Hi,
Window Air conditioners need to tip back just a bit in the window...if they are flat or tipped front you will have the water problem...

Here also is a tip that will help you to keep you Air Conditioner running well...

Window Air Conditioners - Clean them every year
http://www.fixya.com/support/r3623253-window_air_conditioners_clean_every_year

heatman101

May 07, 2010 | Haier hwr10xc6 Air Conditioner

1 Answer

I am turning on my window air conditioner for the first time since last summer. Air is blowing but water is coming out of the vents as if water is inside.


get your AC serviced, due to dust and all the coils are choked this is the reason for water is comming out from the evtns

Mar 19, 2010 | Frigidaire FAC124 wall/Window Air...

2 Answers

Blowing water out the vents.


There is a water pipe from AC to outside,
if a lot of gel inside the pipe, it can make water flow become jam.
Clean it by blow the pipe with a compressor from outside.
Sometimes I did it with my mouth. LOL......
But its worked finally.

Sep 06, 2009 | Goldstar LG LW1804ER Window Air...

1 Answer

Everstar mpm1-10cr-bb6 blowing luke warm air-no water to drain


It shouldn't harm it but give the unit a good cleaning.

May 03, 2009 | Danby DPAC8020 Air Conditioner

1 Answer

Coleman Evron CH/CA unit won't blow the air through the vents


Relay for fan operation in the cooling mode may be bad and not bringing on the blower for the air.

May 22, 2008 | Heating & Cooling

Not finding what you are looking for?
Frigidaire FAC124 wall/Window Air Conditioner Logo

350 people viewed this question

Ask a Question

Usually answered in minutes!

Top Frigidaire Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Are you a Frigidaire Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...