Question about Cfm Daikin R410a Split System Air Conditioner

Open Question

Daikin aircon louver not moving when on

Daikin aircon louver not moving when turn on

Posted by on

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
dvs_redstorm
  • 81 Answers

SOURCE: how to reset the error

more info needed. try fixing the problem then turn unit of at the main power wait for 10 mins then turn on? whats the error code?

Posted on Nov 09, 2010

Ad
hvac1960
  • 2133 Answers

SOURCE: I have a Daikin split

E5 Outdoor activation of compressor over heatprotection or motor lock
Check condenser coil. If dust blocked-clean it.
Check out door fan motor is working. If not replace capacitor or motor.
Check compressor-gradually amps increasing-replace capacitor.
Check for gas pressure. No gas also gives over heat compressor.- Leak test and rectify.

Posted on Jan 16, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to troubleshooting?


First of all, I am not a A/C repairman, but I do repair many other electronic devices. The first thing any repair person will need is a good service manual for the device, and I have found a link to one for you. I went over the site in quite a bit of detail, its a genuine Daikin site and rich with information.

Here is the link, and best wishes!

http://www.aircon-info.com/daikin-ac-service-manuals

Jan 29, 2016 | Cfm Daikin R410a Split System Air...

1 Answer

DAIKIN Aircon Multi Unit - One head unit not working, others are fine. No lights or response


Check for power at unit . If there is power to unit check for blown fuse on circuit board or bad board .

Nov 11, 2014 | Heating & Cooling

1 Answer

ARC433A22 daikin Aircon error code H6, what can I


Its with condensor unit problem. Plz check the code with Daikan error list

Sep 20, 2014 | Heating & Cooling

1 Answer

How to fix Daikin aircon error A6?


This is a fault with the fan coils fan motor.
This could possibly be due to either an issue with the main PCB or the fan motor itself.

Mar 29, 2011 | Cfm Daikin R410a Split System Air...

1 Answer

How to install ceillng casset aircon


Please read carefully and then start work.

http://www.cklimat.ru/user/guides/cassetalg.pdf

Thanks and hope helpful?

Jan 24, 2011 | Cfm Daikin R410a Split System Air...

1 Answer

I have a Daikin split system ducted aircon. temp on 22degrees.turns off error code flashes E5, and a picture of a spanner


E5 Outdoor activation of compressor over heatprotection or motor lock
Check condenser coil. If dust blocked-clean it.
Check out door fan motor is working. If not replace capacitor or motor.
Check compressor-gradually amps increasing-replace capacitor.
Check for gas pressure. No gas also gives over heat compressor.- Leak test and rectify.

Jan 16, 2011 | Heating & Cooling

1 Answer

How to reset the error code on daikin aircon


more info needed. try fixing the problem then turn unit of at the main power wait for 10 mins then turn on? whats the error code?

Nov 06, 2010 | Cfm Daikin R410a Split System Air...

1 Answer

The remote is all lit up but it will not turn the aircon on or let me change any thing on the remote


You have not said which model aircon this is, but from the sounds of things your remote sensor board is faulty. This is usually easily changed by removing the front cover (three screws usually have a click cover over each of them and situated behind the louver) The sensor board has a thin wire which plugs into the main pc board. It can only be plugged in one way.

Mar 02, 2009 | Heating & Cooling

Not finding what you are looking for?
Cfm Daikin R410a Split System Air Conditioner Logo

Related Topics:

115 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cfm Heating & Cooling Experts

David Payne
David Payne

Level 3 Expert

14162 Answers

Brett Duxbury
Brett Duxbury

Level 3 Expert

4198 Answers

Thomas Woodburn
Thomas Woodburn

Level 3 Expert

1918 Answers

Are you a Cfm Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...