Question about Kenmore 53509 Dehumidifier

1 Answer

My dehumidifier will not stop running coils frost up musty odor from it

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 6 Answers

There is a freeze stat on the unit it connects to the evaporater coils it is suppose to shut of the compressor unit when it senses the temp is at freezing the idea is that the unit condenses moisture out of the air like your air conditioner for your house or car this part is dirty or malfunctionong

Posted on May 01, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Frigidaire FDL50s1 runs continuously but will not collect water. What could be the problem & can it be fixed?


Thank you for your post, K!

I understand that your Frigidaire dehumidifier is continuously running and it is not collecting water. This can be caused by a dirty filter. A dirty filter can restrict air flow which will allow your dehumidifier to not pull in air. I would recommend checking your filter to make sure it is clean.

Frost on the coils within your dehumidifier will also cause your dehumidifier to stop working as well. You should check to make sure that there is not frost visible on your dehumidifier. If you do locate frost you would need to perform a manual defrost on your dehumidifier and you can do that by disconnecting power from it for at least two to three hours.

If these steps do not resolve your issue you may need to reach out to the manufacturer for a proper resolution. I hope this information is helpful to you. -Matt

Jun 13, 2015 | Frigidaire Dehumidifiers

1 Answer

The dehumidifier runs but does not remove moisture. The coils are cold but no frost. The inner coil is hot.


Hi,
There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101

May 17, 2011 | Amana D530M Dehumidifier

1 Answer

My dehu has frost on coils most of the the


if the room air is cooler than the dehumidifier then they will frost over. normally frosting over means loss of freon but because it is a closed system there probably isn't. if the air's moisture level [humidity] is low then don't even run the machine.

Oct 25, 2009 | Ebac BD80 Dehumidifier

2 Answers

Dehumidifier


Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off until the frost melts, then comes back on again. For the dehumidifier to work properly, the surrounding (ambient), temperature must be higher than 65 degress. This temperature allows the moisture in the air to condense on the coils and drip into the reservoir without freezing up on the condensor coil. Also, if the humidity is too low, (below 45%), the same condition will occur. So it will help to keep the parameters in mind when you have this issue.

Thank you for your allowing me to advise you on this issue.

Dave E. (Illeagle)

Jun 02, 2008 | Goldstar DH5010B Dehumidifier

1 Answer

Doesnt take any water out


Most dehumidiers have a "Frost Guard" thermal protector on the condensor coil. This protector will turn the compressor off should the temperature fall below 65 degrees in the basement. The condensor fan will still continue to run anticipating the restart of the compressor.
Hence, 3 things could be wrong.
1. air temp.of basement is too cold
2. Frost guard could be faulty
3. Freon leak in condensor coil.
Assuring that basement temp. is above 65 degrees is about all you can do unless you have it checked out by a technician.


May 25, 2008 | Maytag M7DH65B2A Dehumidifier

1 Answer

D50c


Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off until the frost melts, then comes back on again. For the dehumidifier to work properly, the surrounding (ambient), temperature must be higher than 65 degress. This temperature allows the moisture in the air to condense on the coils and drip into the reservoir without freezing up on the condensor coil. Also, if the humidity is too low, (below 45%), the same condition will occur. So it will help to keep the parameters in mind when you have this issue.

Thank you for your allowing me to advise you on this issue.

Dave E. (Illeagle)

Aug 10, 2007 | Friedrich D50C Dehumidifier

1 Answer

Frost, ice on coils DeLonghi DDE50E Dehumidifier


expected? of course! this is not ur solution try draining all the water to the sewerage if u cant try to pump it out with a vacuum cleaner (that can pump water) or a pump then turn on the Dehumidifier every time it frosts turn it off untill it defrosts or u can heat up the basement with a bellower and the Dehumidifier wont frost

Feb 05, 2006 | DeLonghi DDE50E Dehumidifier

1 Answer

Unusual smell


Odors are generally caused by stagnant water or chronically dirty condenser coils. 1) Unplug the unit. 2) Empty the reservoir, mop up any damp areas, and clean the coils with a brush and a garden hose. Note: You can have a dehumidifier's coils steam-cleaned at an appliance-repair or auto-repair shop, but if you do this, have the unit checked after the cleaning to be sure the electrical components haven't been disturbed. Allow to dry in a warm place for at least 24 hours.

Jan 18, 2006 | Fedders A7DH65B2A Dehumidifier

Not finding what you are looking for?
Kenmore 53509 Dehumidifier Logo

Related Topics:

87 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kenmore Dehumidifiers Experts

Bill Long

Level 3 Expert

587 Answers

Mike Squire

Level 2 Expert

404 Answers

Cindy Wells

Level 3 Expert

5125 Answers

Are you a Kenmore Dehumidifier Expert? Answer questions, earn points and help others