Question about GE Profile PSW26P Stainless Steel Side by Side Refrigerator

1 Answer

Top section of freezer is not cooling and ice start melting in ice maker. After several hours freezer starts cooling properly again.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • GE Master
  • 43,501 Answers

Hi,
As the weather is getting warmer for many people their freezerTop section of freezer is not cooling and ice - 2_bing.gif and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning


http://www.fixya.com/support/r4588788-refrigerator_or_freezer_not_cooling_or

http://www.fixya.com/support/r3885294-refrigerator_troubleshooting

http://www.fixya.com/support/r4023749-refrigerator_compressor_start_capacitor

heatman101

Posted on Apr 23, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My freezer coils are completely iced over. How do i fix this?


Its defrost problem.You need to first try manual defrost procedure.This will completely defrost the ice.But if again after few hours or few days, same problem is noticed of coils getting iced, then its defrost problem.--------- In defrost problem, mostly fridge section section stops getting cool.It cools but not properly.----- And freezer section works properly. ------------

The manual defrost reset procedure. The procedure is as follows: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. Then its defrost board problem. -------------

If it's again building up ice that means the unit is not defrosting. It's starting the cooling procedure, and then while defrosting, it's not working. The defrost assembly consists of three main parts. The defrost thermostat, the defrost heater and defrost board. Any of the one is not functioning. When thermostat sense the maximum cooling, it triggers the defrost heater to start heating and this defrosts the ice collected on the coils and the system works. Both thermostat and heater are controlled by defrost board. First the thermostat and defrost heater to be checked, if both check ok by meter and visually, then its defrost board causing the problem. You can get required parts from from online sites like: --- www.repairclinic.com or from searspartsdirect online site. --------- This should help.Thanks.Helpmech.

Sep 11, 2011 | GE (PSS26MSRSS) Side by Side Refrigerator

1 Answer

My fridge is leaking inside. I have a top freezer model and the leaking is happening in the lower fridge compartment in the rear, from above.


The defrost problem.The unit is not defrosting on time.--------

. First try manual defrost reset procedure. The procedure is as follows: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. Then its defrost board problem. -------------

If it's again building up ice that means the unit is not defrosting. It's starting the cooling procedure, and then while defrosting, it's not working. The defrost assembly consists of three main parts. The defrost thermostat, the defrost heater and defrost board. Any of the one is not functioning. When thermostat sense the maximum cooling, it triggers the defrost heater to start heating and this defrosts the ice collected on the coils and the system works. Both thermostat and heater are controlled by defrost board. First the thermostat and defrost heater to be checked, if both check ok by meter and visually, then its defrost board causing the problem. You can get required parts from from online sites like: --- www.repairclinic.com or from searspartsdirect online site. --------- This should help.Thanks.Helpmech.

Jul 08, 2011 | Kenmore Top Freezer Refrigerator

1 Answer

The freezer component is frezzing continuously.


This problem is related to defrost.

Try manual defrost reset procedure: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced. you can get the required parts from online sites like:---

www.repairclinic.com or from searspartsdirect online site.---------

If it's again building up ice that means the unit is not defrosting. It's starting the cooling procedure, and then while defrosting, it's not working. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the fridge section and the fridge section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located.

--------------

This will help.Thanks.Helpmech.

May 16, 2011 | Kenmore Side by Side Refrigerator

1 Answer

Freezer works refrigerator is warm


If the freezer is getting cold and working properly, but fridge section is not getting cold, then it can be defrost issue.------------------ The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the fridge section and the fridge section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located.--------- Try manual defrost reset procedure: ---- First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced. The defrost assembly consists of three main parts. The defrost thermostat, the defrost heater and defrost board. Any of the one is not functioning. When thermostat sense the maximum cooling, it triggers the defrost heater to start heating and this defrosts the ice collected on the coils and the system works. Both thermostat and heater are controlled by defrost board. First the thermostat and defrost heater to be checked, if both check ok by meter and visually, then its defrost board causing the problem. You can get required parts from online sites like: --- www.repairclinic.com or from searspartsdirect online site.This should help.Thanks.Helpmech.

Apr 28, 2011 | Amana Easy Reach 20.5 cu. ft. Bottom...

1 Answer

THe fridge on our fridge freezer isnt working


If the freezer is getting cold and working properly, but freezer is not the it can be defrost issue.------------------ The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the fridge section and the fridge section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located.--------- Try manual defrost reset procedure: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced. The defrost assembly consists of three main parts. The defrost thermostat, the defrost heater and defrost board. Any of the one is not functioning. When thermostat sense the maximum cooling, it triggers the defrost heater to start heating and this defrosts the ice collected on the coils and the system works. Both thermostat and heater are controlled by defrost board. First the thermostat and defrost heater to be checked, if both check ok by meter and visually, then its defrost board causing the problem. You can get required parts from online sites like: --- www.repairclinic.com or from searspartsdirect online site.This should help.Thanks.Helpmech.

Apr 27, 2011 | Refrigerators

1 Answer

I hava a 2 door fridge, the front of the freezer has a little ice and the bottom really is not getting cold


It can be defrost issue.First try manual defrost reset procedure. The procedure is as follows: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. Then its defrost board problem. -------------The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the fridge section and the fridge section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located.----------- The defrost assembly consists of three main parts. The defrost thermostat, the defrost heater and defrost board. Any of the one is not functioning. When thermostat sense the maximum cooling, it triggers the defrost heater to start heating and this defrosts the ice collected on the coils and the system works. Both thermostat and heater are controlled by defrost board. First the thermostat and defrost heater to be checked, if both check ok by meter and visually, then its defrost board causing the problem. You can get required parts from online sites like: --- www.repairclinic.com or from searspartsdirect online site.


Apr 26, 2011 | Whirlpool ET1FHTXM Top Freezer...

1 Answer

Refrigerator isn't cold enough, but the freezer is fine. Model number is PSS26MSWASS, Serial number is GM439772, I turned up the temp for the Refrigerator, but its not that cold.


This problem is related to defrost.The defrost cycle is not running as it should be. The other possibility can be ice blockage in the ventilations.The defrost is not working,.The evaporator coil in the inner section of freezer is got blocked by ice .
Try manual defrost reset procedure: ----
First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.
-------------------------------------------------
Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer works but no cooling in fridge, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets
collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main defrost board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer works but fridge section not getting cold..
---------
You can get required parts from sears part direct online site or from repairclinic.com site.
--------
This will help. Thanks. Helpmech.

Mar 01, 2011 | GE Profile 25.6 Cu. Ft. Side-by-Side...

1 Answer

On the kenmore 363.59522996 side by side the freezer is working good but the fridge will not cool and looking for the cause??


This problem is related to defrost.The defrost cycle is not running as it should be. The other possibility can be ice blockage in the ventilations.

The defrost is not working,.The evaporator coil in the inner section of freezer is got blocked by ice .

Try manual defrost reset procedure: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.

-------------------------------------------------

Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer works but no cooling in fridge, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets

collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main defrost board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer works but fridge section not getting cold..

---------

You can get required parts from sears part direct online site or from repairclinic.com site.

--------

This will help. Thanks. Helpmech.

Feb 25, 2011 | Kenmore 53642 / 53644 Side by Side...

2 Answers

Fridge is not cooling well. Freezer is fine


This problem is related to defrost.The defrost cycle is not running as it should be. The other possibility can be ice blockage in the ventilations.

The defrost is not working,.The evaporator coil in the inner section of freezer is got blocked by ice .

Try manual defrost reset procedure: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.

-------------------------------------------------

Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer works but no cooling in fridge, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets

collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main defrost board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer works but fridge section not getting cold..

---------

You can get required parts from sears part direct online site or from repairclinic.com site.

--------

This will help. Thanks. Helpmech.

Feb 25, 2011 | Frigidaire FRT21P5A Top Freezer...

1 Answer

Over the past couple of weeks, my Side-By-Side Refrigerator freezer has not been running properly. It thaws out for a day or two, then it starts freezing again for a couple more days.


The defrost is not working.This happens due to the evaporator coil in the inner section of freezer is got blocked by ice .--------

Try manual defrost reset procedure: ----

First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. If the same problem occurs then it's defrost problem. The defrost board and the defrost thermostat/heater is not functioning properly and it has to be checked and replaced.

--------------------

Check the damper if there is too much water collected in the damper then press the damper and remove the water collected in it. The procedure of this unit is as follows: --- The compressor starts then it cools the freezer section. When the freezer reaches its cooling level the defrost cycle starts functioning. In this cycle the fan in the freezer section starts running and the cool air in the freezer section is passed to the refrigerator section and the refrigerator section gets cold. The air from freezer to refrigerator passes from the section, in that section the damper is located. Now this problem which you mentioned. In this problem the freezer thaws, this happens if the thermostat is not functioning or the heater is not heating. Then the ice starts getting collected on the evaporator coil. The evaporator coil is at the internal section of freezer. If too much ice gets collected then this ice blocks the fan in the freezer section from functioning and this blocks the damper section with ice getting collected there. This all procedure is controlled by the main defrost board of the unit. Now if the damper is not got blocked with too much water or if the ice is not got collected on the damper area then check the evaporator coils. If there is too much ice got collected on the coils, then takes a hair dryer and melt the collected ice. Then see if the problem returns again. But if there is little bit ice collected on the coils and fan is running properly then it's not a problem. In that case main board is faulty and it has to be replaced. The main defrost board is working but its not controlling the functions as required so the freezer thaws after couple of days.

---------

You can get required parts from sears part direct online site or from repairclinic.com site.

--------

This will help. Thanks. Helpmech.

-----------------

So first try reset procedure.If that is not helping then defrost assembly parts are to be checked and replaced.The defrost thermostat is located in the freezer section beside the evaporator coil.The defrost heater is located in the freezer section beside the evaporator coil.And the defrost control board is located in the fridge section.-------------

you can get the required parts from online sites like:---

www.repairclinic.com or from searspartsdirect online site.---------This will help.Thanks.Helpmech.

Feb 21, 2011 | Amana ASD2625K Side by Side Refrigerator

Not finding what you are looking for?
GE Profile PSW26P Stainless Steel Side by Side Refrigerator Logo

124 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

Sal DeAngelo

Level 3 Expert

2122 Answers

yadayada
yadayada

Level 3 Expert

75807 Answers

dweatherby

Level 2 Expert

239 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...