Question about Hitachi PJTX100 Multimedia Projector

2 Answers

Unit powers up, fan shuts down no light.

When powering up the fan starts for 5 - 10 seconds then shuts down. It tries to restart with same action. The lamp as well does not turn on.

Posted by on

  • Merg Apr 29, 2008

    I would say your troubleshooting was accurate. We had the unit serviced and we were told the fan required replacement. We have the unit back and all is well.



    Thanks

×

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 9 Answers

Go V3 Systems & Services Pte Ltd Singapore 6452 2679
They are Projector Service Centre in Singapore

Posted on Dec 04, 2008

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Hitachi Master
  • 5,568 Answers

The unit could be able to sense fan operation and prevent the lamp from lighting since this could cause heat damage or even a fire if allowed to light without any cooling.
If you can see the fan, try pushing gently on the blades, left, then right, to see if the fan shaft wobbles.

Posted on Apr 28, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Sharp XR-30X starts up then shuts down after 30 seconds.


sounds like it is overheating -- are the fans installed pointing the correct direction, all spinning up well?

Jan 21, 2014 | Sharp XR-30X DLP Projector

1 Answer

Lamp keeps cycling on and off.


the circuit is closed somewhere it shouldnt be

Apr 13, 2013 | Sharp XR-10X Multimedia Projector

1 Answer

Fan Failure Error


the temp sensor probably wore out when the fan did. just replace the sensor. usually located on the lamp housing or near the fans. looks like a transistor.

Sep 28, 2009 | Eiki LC-XG210 Projector Multimedia...

1 Answer

Projector turns on the power light flashing and lamp light solid


Here's the fix: Take off the top cover of the projector. Unplug the wire leading from the two fans in the back of the unit to one of the circuit boards in front of you. Just trace one wire from fan to board. Unplug at board. Turn unit on and it will again turn on, show HP splash screen and then shut down, like it should, because the fans are now disabled. After it completly shuts down, plug the fan wire back into the board. Turn the unit back on and, presto, its working again. It will not turn off.

Try it!

Jun 12, 2009 | HP Digital Projector Vp6120 Multimedia...

1 Answer

Starts to power on,then shuts down


Have you checked the filters? I have a Sanyo PLV-75 and had a similar problem.  The normal fan would come on when the unit was first started, then after a few seconds the secondary fan came on and then the unit would shut down.  Called tech support and they asked if I had cleaned the filters. I did it, and it worked great.  Check the manual for where the filters are and hit them first before getting a new bulb.  Hope it helps!

May 24, 2009 | Sanyo PLC XF10NZ Multimedia Projector

1 Answer

Intermittent Power up / dn


HI-

The projector is overheating, try cleaning the filters for the fan.


Hope this helps

Oct 29, 2008 | InFocus LP 600 Multimedia Projector

1 Answer

Projector shuts off after about 45 minutes


Just a long shot, but...

I have an epson 9000i that did the same thing. Turns out that unit has a small fan (I think 60mm) right next to the power supply to keep it cool, in addition to the large fan that exhausts past the lamp. The fan runs non-stop as long as the unit is powered-up for two reasons I can think of - keep the power supply a little cooler, and the lamp a little warmer so there's not such a temp difference when it powers-up. Long story short, that fan had died. I replaced it with an aftermarket 60mm fan and it's been working fine ever since. Hope this helps.

Bob

Jun 03, 2008 | Epson PowerLite 5550C Multimedia Projector

3 Answers

Compaq MP2800 Lamp powers down after a few seconds


Hi Wayne

It is normal for the lamp's fan to start running , but should actually happen within 15 seconds of starting up. Try changing the lamp's fan and if the problem still persists then you will have to replace the Ballast ( lamp's powersupply )

Mar 22, 2008 | Compaq MP2800 Multimedia Projector

2 Answers

Lamp will not come on


try pressing and holding the enter button on the projector for about 30 seconds - this resets it. It worked for me!!

Feb 10, 2008 | NEC VT460 Multimedia Projector

Not finding what you are looking for?
Hitachi PJTX100 Multimedia Projector Logo

286 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hitachi Office Equipment & Supplies Experts

Electro Med Services...