The heat wont turn on and pilot does not stay lit

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 10 Answers
  • Posted on Mar 07, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Mar 07, 2010
Answers
10
Questions
0
Helped
6357
Points
24

If this is a M/V heater you must have at least 400mv/dc to hold the pilot valve open. Check to make sure that the pilot is lighting, then hold the pilot valve down for about a minute. If the the pilot goes out you need to see what the m/v reading is. Chances are you have a bad pilot or gen. Replace.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

My charmglow control stuck on off and pilot only won't turn to the other settings

Turn off the gas supply and unplug the heater.
Remove the control knob and check for any debris or damage.
Clean the control knob and the area around it with a soft cloth.
Reattach the control knob and turn on the gas supply.
Turn on the heater and check if it works properly.
If these steps don't work, then it's best to contact a professional technician
0helpful
1answer

New kozy world natural gas heater. Pilot light wont stay lit snd heater flame wont stay lit.

Are you holding down the pilot light button long enough for the heat sensor probe to get hot and turn on the gas valve? It takes up to 3 minutes
1helpful
2answers

Oven wont lite

if its a pilot lightr that stays lit all the time,then its the thermocouple next to the pilot light thats bad and cant keep the pilot on
Nov 24, 2012 • Ovens
0helpful
1answer

The pilot light will stay lit. Go to turn on heater and stays on briefly and goes out The heater wont stay lit.

If the fan comes on and blows out the pilot light then you need a new furnace because that's the sign of a crack in the heat exchanger. Need a little better description. Do the burners light then the fan come`s on and then it goes out completely?
0helpful
1answer

Im calling for heat from the thermastat and control panel, the boiler light and and the fan is running, but no matter how many times i keep re trying the pilot and burner will not commence, is there...

I would check to make sure control on gas valve is in on position and pilot is lit if you have a standing pilot. If you have a spark or hot surface ignitor make sure they are trying to lit pilot. If you have standing pilot model and pilot lit is not on. Turn control on gas valve to off,wait five mins. then turn to pilot. Depress botton and try to light pilot. If it lights hold down for a couple of mins. then release.. If pilot stays lit turn control to on. If thermostat is calling for heat this should bring main burner on. If pilot does not stay lit then replace thermocouple. Hope this helps. Thanks
0helpful
1answer

Model: 21v30-7p, pilot wont stay lit

You need a new thermocouple - or maybe the Pilot flame is not lined up properly to the thermocouple? The thermocouple is a "sensor" that is heated by the flame - which in turn keeps the gas supply to the pilot light on. It the pilot light goes out, then the thermocouple no longer "senses" the heat of the flame, so it turns the gas supply off to the pilot to prevent buildup and explosion.
6helpful
3answers

Light pilot on Royal deep fryer. Pilot will not stay lit. Second fryer has larger pilot have no trouble keeping it lit. How can I adjust the pilot so that it will stay lit?

there is a small adjustment screw on the gas valve,turn it clockwise to increase pilot,if that does not work the vent cap on the gas regulator on the back of the unit could be stopped up,remove that cap ,clean out or replace unit can operate without it just fine.If you increase the pilot and it still wont stay lit replace the thermocouple
1helpful
1answer

Torpedo heater wont stay lit.

Do you have the serial number or the manufacture date? There are some design changes and I would need to know the year of manufacture to assist accurately. Usually it is a relay or the thermocouple connection that will affect the unit staying lit.
0helpful
1answer

The heater in my central heating is not getting turn on but the fresh air and cooling is getting turn on

Check the pilot light.Older standing pilot systems use thermocouples to verify the pilot is burning before the gas valve opens.If the pilot wont stay lit replace the thermocouple.
Newer systems light the pilot.On a call for heat the igniter lights the pilot. When the heat is verified the gas valve opens . Some systems use an circuit board with flashing led lights to help troubleshooting.
Not finding what you are looking for?

281 views

Ask a Question

Usually answered in minutes!

Top Teledyne Laars Pool & Spa Experts

Paul Carew

Level 3 Expert

3808 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

deton8 von Splosion

Level 3 Expert

3342 Answers

Are you a Teledyne Laars Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...