Question about Rinnai Toyostove Direct Vent Heater: Laser 30 Toyostove Direct Vent Heater Shipping

1 Answer

My Laser 30 keeps getting a ee 12 code ans shuts

My Laser 30 keeps getting a ee 12 code and shuts down.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

  • Expert
  • 126 Answers

Ken,

The screen for the circulating fan has lint on it. Remove it from the back top panel and wipe it off. The lint keeps the air from be able to blow over the stove and it overheats.

Good luck,

Tom

Posted on Feb 08, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Toyo Laser 30 has an error code EE 5 and I can't find any info on that particular code. Help?


Call manufacturer or Installer - Direct Vent Furnaces are not a DIY service. Carbon Monoxide is deadly and can easily be emitted if there is something wrong with the heater. Get professional help before anything further is done, as it needs a full inspection for your safety.

Apr 14, 2014 | Rinnai Toyostove Direct Vent Heater: Laser...

1 Answer

Stove shuts down and code ee 2 or ee6 comes up , what is my promblem.


Probably a fuel flow problem. Does the pump start making a loud thumping sound before the heater cuts off. Check the fuel filter and the strainer in the fue sump. Turn off the fuel at the barrel before removing the fuel strainer. Also check the flame sensor. Unplug the heater before attempting to remove the flame rod because it may burn out the circuit board if it touches metal with the heater plugged in. Use some steelwool or fine sandpaper to clean it if it is dirty. Another possibility with the EE-6 is that it is overheating, however, since you are getting EE-2 also I would suspect that fuel is the problem. Another thing to check would be the fuel nozzle. It can sometimes get clogged with carbon deposits. Let me know what you find if this doesn't fix it.

Dec 27, 2010 | Rinnai Toyostove Direct Vent Heater:...

1 Answer

EE 8 code on TR-73 toyostove!


If you can't get rid of the EE8 message and you think the motor is really turning it may be turning too slow. This will be caused by corrosion that has dripped down into the blower and gotten on the Rev sensor. The solution is to change the motor. If you are not handy with tools you may have to just change the whole blower. The motor is around $150, the whole blower is $350. The corrosion may have happened over the summer and fall.Heating and cooling causes condensation and the water drips down into the blower.

Tom Hawkins
hawkins111@gci.net

Feb 25, 2009 | Rinnai Toyostove Direct Vent Heater:...

2 Answers

Laser 56 small explostion


I don't think it is dead. I would have a service tech come out and look at it. The igniter sounds like it's not working properly.What kind of fuel are you useing

Apr 06, 2008 | Rinnai Toyostove Direct Vent Heater: Laser...

2 Answers

Cant shut down


keep start button pressed 30 seconds, the pc should turn off. If not brutally unplug the power cable. Do a scan disk on restart.

Feb 16, 2008 | Acer Aspire™ T180 PC Desktop

2 Answers

Ee 12 code


Hi alaskasteve,

My business is Laser Heating Service in the North Pole/Fairbanks area of Alaska. EE12 is the error code for overheating. Most likely you have a Laser 30 giving you this error code. The most common reason for the EE12 error code is that the Toyo is not getting enough air circulation across the heat exchanger and causing it to overheat. Look at the back of your Toyo where the black frame around the circulating fan and flue pipe is. You will see a screen that slides in a slot at the back of the Toyo. Slide the screen out and clean it. If you have a smoker or the Toyo is in a kitchen area where it collects nicotine or grease then you may need to clean it with hot water, detergent, or 409 Cleaner to get the sticky residue off that the dust fuzz collects on and clog your screen. EE12 can be caused by a couple other issues, but they are more rare. Try this first and let me know if it works! toyotechnician

Jan 15, 2008 | Rinnai Toyostove Direct Vent Heater: Laser...

1 Answer

My Heater shuts down and I don't have a manuual to trouble shoot it.


I NEED TO KNOW WHAT THE EE2 CODE MEANS.ON YOUR FURNACE THERE IS A LIST OF ERROR CODES,PROBABLY ON THE BACK OF THE DOOR ON THE HEATER.WE NEED TO START FROM THERE TO GET AN UNDERSTANDING OF WHAT THE UNIT IS TRYING TO TELL US. JEFF

Dec 15, 2007 | Heating & Cooling

2 Answers

Laser 30


EE 8 means there is a problem with the blower fan. It could be faulty or it could just be stuck. Did you leave the heater off for a long time? Like all summer? If so then it is probably just stuck. You can easily check if it is just stuck by following these steps: turn the heater off. grab a flashlight and a screwdriver and kneel down next to the left side of the heater as you are facing it. Look behind the heater near the bottom and you will see a flexible gray rubber L-shaped hose that is attached to the blower fan housing. This is the fresh air inlet for the heater. Next, loosen the hose clamp screw on the gray rubber hose elbow that attaches to the back of the heater. You may need a stubby screwdriver depending on which way the clamp is facing. Pull off the rubber elbow and stick your finger into the hole in the blower housing. You should feel the fins and hub of the round fan. This should turn freely. If it doesn't, then you can try to spin it with your finger a few times as you turn the heater back on. Do this carefully, you don't want to bend or warp the fan. If it begins to spin freely, you should hear it and there will be some slight suction INTO the housing. It may work normally now, although it will likely make more noise than it used to, due to the motor bearings being inactive for a while. Replace the rubber hose and clamp, and run the heater on high for a while by adjusting the SET temp up. It is important with the Laser 30 to run it frequently, even at a low setting in summer to keep this from happening. If you turn it off and let it sit for even a few days or weeks at a time, this will probably happen again.

If this does not fix your problem, email me at toyofreehelp@yahoo.com

Nov 10, 2007 | Rinnai Toyostove Direct Vent Heater: Laser...

1 Answer

Toyostove Laser 30 has error code EE 22


EE-22 means that the unit has tried three times to ignite. after this it goes into a "lockout" condition. remove the power and the computer will reset itself. it will then try to re-ignite. check for a fuel blockage, dirty filter etc. if there's water in your kerosene it will not fire! kerosene floats on top of water. bleed your system until you get kero and no water. use a gas additive to remove water. dry-gas will work. just empty the bottle's contents into your tank. on your computer type in toyostove error codes. this will take you to toyo's site and explains the error codes.

Oct 20, 2007 | Rinnai Toyostove Direct Vent Heater: Laser...

Not finding what you are looking for?
Rinnai Toyostove Direct Vent Heater: Laser 30 Toyostove Direct Vent Heater Shipping Logo

481 people viewed this question

Ask a Question

Usually answered in minutes!

Top Rinnai Heating & Cooling Experts

Paul Carew

Level 3 Expert

2799 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

vance jones

Level 2 Expert

120 Answers

Are you a Rinnai Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides