Question about Weiser Lock Powerbolt 1000 Lock

2 Answers

Our Powerbolt 1000 will not delete old codes.

Posted by on

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 18 Answers

Are you certain you're programming new codes properly? It should just overwrite the codes when new ones are programmed. If you are doing it right, then I'd say you may want to have the unit repaired/replaced...
To program new codes (just in case):
Push the program button on the control board once for memory 1 OR twice for memory 2. Enter a 4-8 digit code. Push the lock button to end the entry. The unit will emit a 2-second long beep if your code is accepted. (If it doesn't beep, you were too slow. Try again.) Repeat the process for the other memory position.

Posted on Feb 07, 2010

  • qk_revilla Aug 31, 2010

    I had the same exact problem. Follow GalxyT25 instuructions they work! Yes, to erase old codes just make sure you enter new codes for both memories. Also as GalaxyT25 mentions enter the code as soon as possible after you hit the back button. That was my problem. His instructions worked beautifully. Thanks a million.

×

Ad
  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I had the same problem with myPowerbolt 1000. I could not erase codes. In despiration, I tried entering a 3rd code by pressing the control button 3 times (after entering 2 new codes as explained by Galaxy T25 above). IT WORKED! The old codes were gone.<!-- from fixya rte -->

Posted on Aug 13, 2010

  • xgenx Jan 09, 2011

    We were able to change 2 codes by GalxyT25/s instructions but couldnt clear the mastercode. We then pressed the programme button 3 times as suggested by mikey556 and re-entered a new code and it l changed the mastercode. Thanks.

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Deleting Codes on a Weiser powerbolt.


The Weiser brand and Kwikset brand Powerbolt are identical (Black & Decker), so these instructions will work just fine for you:

http://www.kwikset.com/Customer-Support/Product-FAQs/Faq/50160000000HhhEAAS.aspx

Notice that the above is a .PDF file type. That means that you need to have Adobe Reader or similar installed on your computer to view it. So if you are unable to view the file, download (for free) and install Adobe Reader first. You can get it here:

http://get.adobe.com/reader/

Jul 09, 2012 | Weiser Lock POWERBOLT ELEC DEADBOLT

1 Answer

Any four digit code works no matter how many times you reset code. how do you erase all codes and start fresh?


How do I change the access code (and delete my old code) on my Powerbolt 1000?

The steps below are to change your access code to a new code. This will also remove any previous codes stored in the Powerbolt's memory.

pb1000programbutton

  1. Manually put the bolt in the extended (lock) position. Press the PROGRAM button once, enter your new 4 - 8 digit code and then press the LOCK button.
  2. Press the PROGRAM button twice, enter the same new code and then press the LOCK button once.
  3. Press the PROGRAM button three times, enter the same new code and then press LOCK once.
If your old code still remains in the unit, you will need to perform a hard reset of the unit. To perform a hard reset of the unit, remove all four batteries and leave them out for 1 hour. After the hour has passed, you may re-enter the batteries.


I'd recommend replacing the batteries if you haven't done so yet.
Good luck--and please provide feedback if this helps!

Aug 21, 2011 | Kwikset Powerbolt/Electronic Deadbolt-...

1 Answer

How do I clear (erase) all codes from my Weiser Powerbolt 1000 in order to start with fresh entries? Adding new codes does NOT override/delete old existing codes as page 7 of my manual indicates. I now...


How do I change the access code (and delete my old code) on my Powerbolt 1000?
The steps below are to change your access code to a new code. This will also remove any previous codes stored in the Powerbolt's memory.

pb1000programbutton.jpg

  1. Manually put the bolt in the extended (lock) position. Press the PROGRAM button once, enter your new 4 - 8 digit code and then press the LOCK button.
  2. Press the PROGRAM button twice, enter the same new code and then press the LOCK button once.
  3. Press the PROGRAM button three times, enter the same new code and then press LOCK once.

If your old code still remains in the unit, you will need to perform a hard reset of the unit. To perform a hard reset of the unit, remove all four batteries and leave them out for 1 hour. After the hour has passed, you may re-enter the batteries.



United States of America Customer Service Contact Information
Call Us Toll Free: 800-422-4278 (Mon-Fri, 6:00am - 4:30pm PST)


http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Good luck, Elizabeth!


Jul 26, 2011 | Weiser Lock Powerbolt 1000 Lock

1 Answer

I need to reset the code


How do I change the access code (and delete my old code) on my Powerbolt 1000?
The steps below are to change your access code to a new code. This will also remove any previous codes stored in the Powerbolt's memory.

pb1000programbutton.jpg

  1. Manually put the bolt in the extended (lock) position. Press the PROGRAM button once, enter your new 4 - 8 digit code and then press the LOCK button.
  2. Press the PROGRAM button twice, enter the same new code and then press the LOCK button once.
  3. Press the PROGRAM button three times, enter the same new code and then press LOCK once.
If your old code still remains in the unit, you will need to perform a hard reset of the unit. To perform a hard reset of the unit, remove all four batteries and leave them out for 1 hour. After the hour has passed, you may re-enter the batteries.

Jun 22, 2011 | Weiser Lock GED1460X3BR Lifetime Polished...

1 Answer

I am looking for a manuals for a weiser lock powerbolt 1000 can i down lord


powerbolt 1000

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Here's a link to the Frequently Asked Questions page for the Powerbolt 1000:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

The instructions for reprogramming the code can be found there. Good luck!!

Apr 07, 2011 | Weiser Lock ED1460X3VKD Powerbolt 1000...

1 Answer

How do you wemove the cover to replace the batteries and how do yu set the code? This is an old unit I bougth in 1996 and never installed it untel the outer day. T/Y


Here is a link to the Frequently Asked Questions page for the Powerbolt 1000:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Removing the cover to change the batteries is illustrated there. Good Luck!

Feb 08, 2011 | Deadbolt Weiser Powerbolt 1000 Keyless...

1 Answer

How do i program 2 differt codes and erase old codes


Here's a link to the Frequently Asked Questions page for the Powerbolt 1000:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

The instructions for reprogramming the code can be found there.  Good luck!!

Oct 26, 2010 | Weiser Lock POWERBOLT ELEC DEADBOLT

1 Answer

How do you cancel existing codes?


The codes should be overwritten when you program in a new code.

Here's a link to the Frequently Asked Questions page for the Powerbolt 1000:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

The instructions for reprogramming the code can be found there. Good luck!!

Aug 09, 2010 | Weiser Lock Powerbolt 1000 Lock

1 Answer

After changing the code, it will not delete the old ones. how do you do that?


Be sure to change both codes. Press "program", then the code, then the lock button. Then press "program" twice, then a second code, then the lock button.

Nov 30, 2009 | Weiser Lock Powerbolt 1000 Lock

Not finding what you are looking for?
Weiser Lock Powerbolt 1000 Lock Logo

626 people viewed this question

Ask a Question

Usually answered in minutes!

Top Weiser Lock Locks & Locksmithing Experts

Jim Goldsmith
Jim Goldsmith

Level 3 Expert

2005 Answers

john h

Level 3 Expert

13651 Answers

Cindy Wells

Level 3 Expert

5381 Answers

Are you a Weiser Lock Lock and Locksmithing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides