Question about Coleman Powermate Powermate 5000W Generator

1 Answer

I have a coleman generator Maxa 5000 ER PM0525302.02 ,what is the ON position "I" or "0" ?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 394 Answers

"I" is on.

Posted on Jan 31, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Serges up and down and stalls after a fes coleman maxa 5000 er plus


Hi mxdidit,

Surging is generally caused by carburetor problems. Squirt some carb cleaner in it and see if that helps it at all. If that helps but does not do a lot, then the carb probably needs to be rebuilt. The carb could also just need some adjusting. Check for fuel leaks around the carb and also be sure the air filter is clean.
Good luck.

Hope this helps. If it does, I'd appreciate your vote. Thanks,

Handie Andie

Jun 10, 2011 | Coleman Powermate Premium Plus 6250W...

1 Answer

Hello, I'm trying to get an old Coleman Maxa 5000 ER Plus to work again. The interesting problem is that i can get it to start and run, IF i squirt gasoline into the carb throat with a squirt sprayer, but...


First make sure you have fresh gas in the tank, as old gas can cause a 'no run' condition. Once you have fresh gas in the tank, make sure the gas flows freely all the way to the carb by removing the fuel hose from the carb inlet & checking for good flow (bad shut-off valve or obstructed hose by debris could cause same problem). Once you are sure that good, fresh gas is going into the carb w/o obstruction, remove the lower bowl from the carb - carefully - do not lose ANY parts, starting with the washer on the bolt. With fuel flow 'ON', fuel should flow freely when this bowl is removed, so shut off fuel valve in the hose. Now, if you carefully remove the bolt / brass tube from the center of this bowl area (center of plastic float) - remove bolt downward, like you would a lightbulb from the ceiling - this bolt should have several holes in the side, they are probably clogged, so unclog them with a needle or wire, wipe clean, and reinstall. That probably just solved all your problem.... if not, you likely will want to replace the carb completely, as it is not very expensive, and will surely solve your problem. *** Be careful with gas fumes !!! ***

Dec 21, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

Coleman powermate maxa 5000 er - been sitting for about 2 years and I want to start it up again. Checked oil, ok. added new gas (but did not drain old). Fuel valve open, spark plug cap on. Engine won't...


it could have sezed up on you take out the plug and try to turn the motor by hand if it wont turn its sezed up,,,if so all you can do is tip down the plug hole a small brop of red x or two stroke oil and rock the motor back and frow till it frees off,,
if it frees off that is!

Aug 30, 2010 | Electrical Supplies

1 Answer

It is not a problem like to know if i can use my coleman 5000 maxa er plus 10 hp. With A welder with out damage it. Tanks


Yes, you can use a welder with it. Pay attention to the ratings of the welder, don't exceed running watts of the generator. It would also be a good idea to try and use a welder that is less than the running watts rating of the generator. Then you would have some extra capacity to deal with fuel quality, maintenance history, momentary undervoltage, altitude, etc.

Jun 20, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

How do you convert the (2) 240 volt outlets to one twist lock connector on a coleman powermate maxa 5000 er genset


Make an Umbilical recepticle adapter. Buy the recepticle install the recepticle in a 4" electrical BOX on a plate with two manufactured 3 prong power cords plugging into the 2 outlets and terminating at the new Box twist lock recepticle you made.

Feb 09, 2010 | Coleman Powermate Powermate 5000W...

1 Answer

Powermate Maxa 5000 er will not run stably


Check the fuel filter. My company designed hybrid generators that are far more efficient. They use batteries to power your equipment, and the generator runs intermittantly to recharge the batteries when needed.

If you would like to convert to hybrid, contact me at buffalonymann@yahoo.com

Sep 24, 2009 | Coleman Electrical Supplies

Not finding what you are looking for?
Coleman Powermate Powermate 5000W Generator Logo

Related Topics:

1,239 people viewed this question

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

John Trevino

Level 3 Expert

1388 Answers

Phil Walker
Phil Walker

Level 3 Expert

608 Answers

Tim Garcia
Tim Garcia

Level 2 Expert

66 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...