Question about Fujitsu 18C1 Air Conditioner

3 Answers

Fujitsu Inverter ASTA09LCC - heating not working

I have the above reverse cycle airconditioner but i cannot get the heating to work. When i switch on the remote, the units Operation Indicator light and Timer Indicator light flash simultaneously. I think it has something to do with the Test Run button being pushed but the manual does not say how to fix this, apart from saying to press the Start/Stop button. Obviously I've done that and it is not the answer. Can anyone help? :)

Posted by on

  • 1 more comment 
  • Anonymous Jun 21, 2008

    no heat , operation light flashes five times in intervals and the timer light flashes continuously model number AST24LBAJ

  • cheerio7 Jul 09, 2008

    I have the same problem, the airconditioner works fine but when i switch it to the heater - no air comes out. the operation light keeps flashing. the out outside outlet makes a noise as if it is working but no hot air is coming out. HELP!

  • abeer Feb 15, 2012

    i have the same problem and the solutions dont work pls help me

×

3 Answers

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

Use a pen to hit the reset button on the remote. 

Posted on Feb 11, 2009

  • geoffmoran20 Apr 29, 2011

    I found that if you go to the meter board and turn off the power as bobofel said above. Still can't get the fan to work though.
    Not good if I have to go through this every winter.
    Geoff

×

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 236 Answers

Try to reset the unit by unplugging the power supply or off the circuit breaker for 10 sec. the "on" again and operate the unit. But if it wont work You need a qualified technician to correct the problem.

Fujitsu Inverter ASTA09LCC - heating not working - fde09a1.jpg

Posted on Mar 09, 2008

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

I have the temperature gauge set to 24 to heat and only cold air is coming out. Help?

Posted on Aug 05, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What does 3 green led flashes in sequence, operation led off mean on Fujitsu ASTA09LCC aircond


This means a "Serial reverse transfer error during the operation"
Diagnosis:
When the indoor unit does not receive the signal for 10 consecutive seconds during the operation
>Permanent stop after 30seconds.
[Diagnosis Point]
Check the indoor /outdoor cable connection (in order). If the cable wiring is not abnormal, measure the voltage of the outdoor
unit terminals and diagnose the defective location.
(Refer to the after mentioned [Serial Signal Diagnosis] for the voltage measuring method and diagnosis method.)

This is generally caused by a faulty controller board in the outdoor unit. Often they are shorted out by geckos or bugs but sometimes a power surge.

Jul 14, 2015 | Fujitsu Heating & Cooling

2 Answers

Why isn't it heating?


Because its an air conditioner, not a heater?

May 03, 2015 | Heating & Cooling

1 Answer

We have fujitsu inverter plasma airconditioner mpdelastb09ldc ths fan runs but timer light blinks 3 times but outdoor does not start


Hi Rajneel,
I hope this link is of some help to you
Good luck
http://www.climatecenter.co.uk/wcsstore/ClimateCenter/Attachment/downloads/fujitsu-trouble.pdf

Feb 10, 2015 | Fujitsu Heating & Cooling

1 Answer

I have a fujitsu reverse cycle aircon AOT36RCD3L had power switched off for 5 hrs now compressor is not working self diagnosis is saying E 100 inside fan is still working what do you do to get it working...


Hi Mark,
I hope the following link is of some help for you?
Good luck
http://errorcodeairconditioning.blogspot.com.au/2010/10/fujitsu-air-conditioner-error-codes.html

Feb 05, 2015 | Fujitsu Heating & Cooling

1 Answer

Timer light flashes twice on my asta09lcc but it wont work


If operation light is normal and timer light flashes twice, the error is:
Serial signal (reverse) error, at operation start up
Most likely a faulty outdoor controller PCB. Around $250 for new board plus labour.

Jul 09, 2012 | Fujitsu 18C1 Air Conditioner

1 Answer

Fujitsu Inverter ASTA09LCC Where is the drain tube located? The air con is leaking water and I believe drain may be blocked.


It is directly behind & thru the wall to outside next to the refer. piping.Everything goes outside thru a 3" hole. tube should b there.Blow it out.good luck

Mar 12, 2010 | Fujitsu 18C1 Air Conditioner

1 Answer

CODE FLASH 2TIME


fujitsu clear the code

Feb 14, 2009 | Fujitsu 18C1 Air Conditioner

1 Answer

Manual for Akai reverse cycle airconditioner remote control


I have a Akai AC-GP10HRCI model portable air conditioner. We have lost the manual. It shows F8 on the display panel board and is not working at all. Please help. Thank you!!

Jun 08, 2008 | Heating & Cooling

2 Answers

Mitisubishi Ducted Reverse Cycle AirConditioner


1.check blower fan motor.if blower fan motor donot work then compressure trip after 5 to 10 minitue.
2.make switch of airconditioner n reset again.

Feb 11, 2008 | Mitsubishi MS12TN Air Conditioner

Not finding what you are looking for?
Fujitsu 18C1 Air Conditioner Logo

6,611 people viewed this question

Ask a Question

Usually answered in minutes!

Top Fujitsu Heating & Cooling Experts

Fotis Papastamatiou

Level 2 Expert

96 Answers

AJMAL KHAN

Level 2 Expert

382 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Fujitsu Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...