Sears Craftsman LiftMaster Chamberlain Garage Door Opener Wireless Keypad Model 976LM Security+ Logo
Posted on Dec 26, 2009
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

My craftsman door opener went up half way and stopped. Light on u nit was not on and indicator light flashed 5 times, the repeats 5 flashes. billybob

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 3,197 Answers
  • Posted on Dec 28, 2009
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Apr 29, 2009
Answers
3197
Questions
1
Helped
1458750
Points
8183

The code for that light flashing 5 times is 'motor overheated or RPM sensor failure'. The RPM sensor is a small printed circuit board just in front of the motor. Release the door from the opener and operate by hand. It should raise easily and should stay put when it is about waist high.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

The unit is displaying a sequence of 5 flashes with the amber light. When I try to open the door, it will only go forward and backward aprrox. 1 ft. Any suggestions on what I should do?

Craftsmsman 1/2 HP opener indicator light blinks five times ...

? 0:29
https://www.youtube.com/watch?v=AvXJd-tYCJ0
Apr 28, 2012 - Uploaded by bship452
Then showing the amber indicator light blinking 5 five times, stops ... push remote to operate opener, you hear a clicking sound from the unit. ... Show more .... blink 5 times (looks almost alike) If I forced the garage door closed, ...Missing: sequence

Sears Garage door opener problem - Home Forums

ths.gardenweb.com > Home Forums > Garages/Workshops
Jun 27, 2006 - Now, I cannot get the light in the sensor at the door to come on. ... the green LED went OUT about 1/2 way up the door opening sequence. .... other is working (I don't recall if it's green or amber, but know that it is lit.) ... Their is also a green LEDflashing 2 times every 5 seconds or so at control center of unit.

Craftsman Garage Door Opener Problem - Home Forums



0helpful
1answer

My Chamberlain Liftmaster Formula 1 garage door (2002) has stopped working. The power is on -- light turns on when I push the wall mount button. But the remotes no longer work. The door does not move. ...

The light by the learn button may be sending a diagnostic code. See if it is flashing a number of times, pausing and then repeating. Count the flashes. Is your door stuck in the open posititon?
0helpful
1answer

I have a craftsman 1/2hp that stopped working. There is a small green light on the back of the opener that flashes five times and then stops for a second and then repeats the flashing. It may be model...

You don't say but I am going to assume the door is stuck in the open position. Loosen the chain enough to relieve the tension on the trolley. Now run the opener until the door closes. While the door is closed locate the 'up limit' control on the side of the motor unit. Turn this control 2 full turns in the opposite direction of the arrow printed on the cover. Tighten the chain.
0helpful
1answer

My Chamberlain Liftmaster garage door opener will not stay closed. It will start down and about half way it will stop and reverse itself. At times it will work properly. When the bounce happpens the light...

Anytime the main light flashes 10 times and the door reverses to the open position it is a door sensor problem. Make sure they are pointed at one another and the small light on each one is lit and not flickering. If you cannot get both lights to come on you have bad sensors.
0helpful
1answer

Door starts and stops. I have: Adjusted down force controls still starts reverses then stops checked door sensors OK checked motor OK

If the main light flashes 10 times when the opener reverses it is a door sensor problem. Make sure they are pointed at one another and that the small light on each one is lit and not flashing. Check the small LED on the back of the opener. If it is flashing 5 times and pausing and then repeating you most likely have a bad RPM sensor board which is a small printed circuit board near the front of the motor.
0helpful
1answer

The track only goes down about a foot then goes back up a foot and stops

If the main light flashes 10 times when the door reverses you have a door sensor problem. Make sure one of them hasn't been bumped and that they are pointed at one another. Each one has a small light that should be lit and not flickering. Both lights will only be on if they are properly aligned. If the main light is not flashing then you probably have a problem with the RPM sensor which is a small printed circuit board just in front of the motor. Usually when this is bad the small LED near all those white wires will be flashing 5 times then pausing and repeating.
3helpful
1answer

Craftsman garage door opener will not work. model # 139.53648SRT2

The code it is sending by flashing 5 times is 'RPM sensor or motor overload'. Is the door stuck in the open position?
1helpful
2answers

Motor moves 5 in" and reverses and light blinks 5 times

In the manual it says if you can hold the wall button down & door closes. You have a short in the wiring to the reciever eye. Try substituting some new bell wire in its place, or test the wires for continuity.
0helpful
1answer

Chamberlain 1/2hp won't open/close and learn LED flashes 5 times

The gear needs to be changed kit #41c4220a. Be sure to change the bottom bushing on the motor mount.
0helpful
1answer

Door opener moves foward about 10 inches then returns

UNPLUG THE UNIT FOR ABOUT 5 MIN. TO RESET TRY TO OPERATE IF IT STILL MOVES 6-8 INCHES AND FLASHES 5 TIMES THE RPM SENSOR IS YOUR PROBLEM - COULD JUST BE THE CUP HAS MOVED ON THE SHAFT. IF IT IS IN PLACE AND STILL NOT WORKING REPLACE THE PICKUP.
Not finding what you are looking for?

415 views

Ask a Question

Usually answered in minutes!

Top Sears Building Materials Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

hsapiens

Level 1 Expert

6 Answers

Are you a Sears Building Material Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...