Question about Powerware PowerRite Plus UPS System

1 Answer

UPS emits a regular beep at about 5 minute time lapses - what is the problem?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 8,404 Answers

My guess it it is trying to get your attention for some reason. While I am not familiar with this brand, the competition brand beeps because of battery failure or impending failure.

Thanks for your interest in FixYa.com

Posted on Dec 12, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Error light in my apc smart ups sc 1500va ups


1. Four beeps every 30seconds (On Battery LED will be illuminated)
This alarm indicates that the Battery PowerSupplied outlets are now supplying battery power as opposed to power from theutility. If the UPS determines that the input utility power is unsafe for yourcomputer equipment, the UPS will switch to battery power.
Note: Ifthe power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will beilluminated)
This alarm indicates that a Low Batterycondition has been reached and that the UPS will soon shutdown. Once the UPStransfers to On Battery operation, it can only stay on battery for a limitedamount of time. The UPS will sound this alarm about two minutes before thebatteries are totally exhausted. Once exhausted, the UPS will shutdown and turnoff its output power to your equipment. If you hear this tone you shouldimmediately shutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (BackUPS OFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected anOverload condition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload wasdetected while the unit was on-battery operation. This tone will continue tosound until the unit shuts down.

5. Continuous Tone (On Battery LED will beflashing)
This alarm indicates that the battery-poweredoutlets are overloaded.

6. Continuous Tone (On Line and On BatteryLEDs flashing) Back UPS OFFICE 350,400, and 500 ONLY
This alarm indicates that an internal UPS faulthas occurred.

Dec 08, 2011 | APC Smart-UPS SC 1500VA UPS System

1 Answer

The battrey leds stay flashing i changed battries also the led still flashing


Automatic: The UPS performs a self-test automatically when turned on, and every

two weeks thereafter (by default). During the self-test, the UPS briefly operates the

connected equipment on battery.
Manual: Press and hold the button for a few seconds to initiate the self-test

REPLACE BATTERY LED ILLUMINATES

Replace Battery LED flashes and

short beep is emitted every two

seconds to indicate the battery is

disconnected.

Check that the battery connectors are fully engaged.

Weak battery. Allow the battery to recharge for 24 hours. Then, perform a self-test. If the

problem persists after recharging, replace the battery.

Failure of a battery self-test. The UPS emits short beeps for one minute and the Replace Battery LED

illuminates. The UPS repeats the alarm every five hours. Perform the self-test

procedure after the battery has charged for 24 hours to confirm the Replace

Battery condition. The alarm stops and the LED clears if the battery passes the
self-test.

Sep 09, 2011 | APC Smart-UPS RT 5000VA (SURTD5000XLI) UPS...

1 Answer

Weiser lock began to emit a single long beep at regular intervals of several minutes. Changed the batteries and reset the code and it works fine, however, still continues to emit a single long beep at...


Why is my Powerbolt 1000 unit beeping?

To determine why your lock is beeping abnormally, please follow these steps:

Take out batteries and unplug powerstrip.
Let it sit for 1 minute, then put the batteries back in and wait another minute.
If it does not beep, the keypad needs to be replaced (17733-1).
If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).

The complete page that I cut this from can be found by cutting and pasting this link into your browser search bar:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Since you've already gone through the battery change, this suggests that you need to replace the appropriate Powerboard for your lock.
So this is the link to Weiser Customer Support Page. Here you will find the appropriate contact numbers, US or Canada:

http://www.weiserlock.com/en/CustomerService/ProductSupport/SupportContact.aspx

I suggest calling the appropriate toll-free number and having a conversation with a representative about this problem, first of all to confirm that you need the part before you go through the expense. Secondly, your lock may be new enough for you to talk them into warrantying it, and thirdly, they will be able to get the correct part on order for you.

Good luck!

Aug 04, 2011 | Weiser Lock POWERBOLT ELEC DEADBOLT

1 Answer

We had a power outage for about 45 minutes a few days ago. Ever since then the Powerware 3110 has been beeping. I turned it off and left it plugged in overnight and when I turned it back on the beeping...


This could be several things, fortunately the device should actually be helping you to diagnose the issue. There are different beeps for different issues. They are as follows:

1 Beep Every 5 Seconds = Power Outage\Loose Plug Connection\Tripped Circuit Breaker\Power Cord Damage or Failure

2 Beeps Every 5 Seconds = Low Battery Alarm

3 Beeps Every 5 Seconds = Battery Needs Charging\Service\Replacement

3 Beeps Every 5 Minutes = The Battery is discharged and battery power is unavailable (If this continues battery replacement may be necessary)

1 Beep Ever 1/2 Second = Power Requirements exceed the UPS Capacity (remove some equipment to lighten the load on the unit)

Continuous Beep = Short Circuit / Input Voltage out of Range / UPS Fault (Likely replacement of entire unit)

That should help diagnose the actual issue. If it turns out the battery needs to be replaced they can be found online for around $20. A simple google search for Powerware 3110 Battery should return what you're after. Good luck!

May 05, 2011 | Powerware 3110 UPS System

1 Answer

Good afternoon The system has a red light flashing constantly and is emitting 3 beeps every thirty seconds. Thanks for your help.


The battery in your UPS needs to be replaced. You can contact the manufacturer for a replacement battery -- depending on your warranty, they may replace it for free.
http://powerware.eaton.com/Products-services/Backup-Power-UPS/3105.aspx?cx=3

Mar 17, 2011 | Powerware 3105 500i (0790341043681) UPS...

1 Answer

Opti-UPS 1400ES UPS unit - Beeping 14 Times, stops, Beeps Again.


you can try this asia systems technologies look for our sale person william +65 65478990 william@asiasystemstech.com i suspected that now that u UPS is have hardware issue.. to determine if the unit is really the problem it hav to be do a further diagnos..

Mar 04, 2009 | Opti -UPS PowerES 1400 UPS System

2 Answers

Powermust 600 USB 5 minutes shuting down problem


Load is the problem. Too low load on UPS will cause that on almost all Musteks.

Dec 12, 2008 | Mustek UPS 600 (POWERMUST600USB) UPS...

1 Answer

Can I switch a video from time lapse mode after it has been shot?


No. Time-lapse video is recorded at a much lower frequency than regular video. The information between recorded frames is gone.

Imagine taking a picture out of your office window once an hour. You might catch some cars moving and/or people walking, but you won't be able to see what happened between the pictures.

You can go the other way, from a regular video to a time-lapse video by skipping frames. Unfortunately you can't do the opposite without guessing at what happened in between.

May 23, 2008 | Canon PowerShot SD750 / IXUS 75 Digital...

Not finding what you are looking for?
Powerware PowerRite Plus UPS System Logo

Related Topics:

171 people viewed this question

Ask a Question

Usually answered in minutes!

Top Powerware Computers & Internet Experts

Marvin
Marvin

Level 3 Expert

83508 Answers

geekyshrink
geekyshrink

Level 1 Expert

43 Answers

Joe Lamb
Joe Lamb

Level 3 Expert

463 Answers

Are you a Powerware Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...