Question about All-Pro Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater

1 Answer

I have a all pro 55,000 btu heater and when i turn the switch on you can see the igniter come and then the fan will come on for maybe 10 seconds the it shuts off. any ideal why it want run?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • All-Pro Master
  • 3,249 Answers

Hi it could be ablocked pressure switch jump it and see if it runs

Posted on Jan 22, 2010

  • Paul Carew Jan 22, 2010

    Hi it could be ablocked pressure switch jump it and see if it runs

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Reddy heater 30-55,000 btu.. When lighting it I press in the initer for the recomended time but after I release it the flame goes out.. Can you tell me why?.


It seems as if you are not holding the igniter long enough after it fires, have you tried holding the igniter down for a few seconds more to allow the safety cut out to warm up, (Similar to the gas heaters, when ignited keep the flame going for the thermal coupling to heat up), If you do this and it still goes out the safety valve is faulty, but try holding it in longer before messing about with the coupling.

Jan 05, 2012 | Reddy Heater-30-55,000 BTU Variable

1 Answer

Heaters runs for a few minutes then shuts off.


was working fine refilled it and now it will run 5sec. and kick the breaker on it.It's an old 80's model 35,000 B.T.U. I cleand the photo eye with a cloth no change. Any solution's

Jan 29, 2010 | Reddy Heater-30-55,000 BTU Variable

1 Answer

When filled with kerosene then plugged in, the heater will kick on for about 3 seconds and the fan will run but it will not ignite, then it shuts off. reddy heater 55, 55000btu. runs on K1 or fuel oil.


REDDY HEATER 40 KEROSENE FIRES UP FOR A FEW SECONDS AND QUITS WITH A WHITE CLOUD OF SMOKE COMING OUT THE END
MY REDDY HEATER 35 KEROSENE RAN OUT OF FUEL AND WILL NOT RUN AT ALL WHEN PLUGGED IN

Jan 11, 2010 | Reddy Heater-30-55,000 BTU Variable

1 Answer

55,000 btu reddy heater. I turn it on and the tip does light and the fuel will spray for a second and the fan turns on but it will not stay on but for about 10 seconds. not sure whats wrong.


need to set the air pressure.you need to have a gauge to set it correctly.the heaters with glow bars do not work the same as old style.the flame has to be in the correct possition for the unit to work.

Mar 01, 2009 | Reddy Heater-30-55,000 BTU Variable

1 Answer

Trys to start. Motor turns slowly (revolution in 2-3 seconds).


Either:
  1. the reset (safety control) is bad
  2. the photocell is defective
  3. both of the above
To test the photocell http://reddyparts.com/photocell_test_sp.htm

Nov 29, 2008 | Reddy Heater-30-55,000 BTU Variable

2 Answers

Reddy heater 55,000 BTU will not ignite


Ours did that too one year. Seems to me we changed the spark plug, it had spark but too weak I think.

Jan 31, 2008 | Reddy Heater-30-55,000 BTU Variable

2 Answers

Reddy heater won't stay on


sounds like a Thermal Cut-off this is a small sensor that detects if the heater has ignited properly, sounds like this sensor has failed and the heater shuts off to prevent from gassing anyone

Nov 02, 2007 | Reddy Heater-30-55,000 BTU Variable

Not finding what you are looking for?
All-Pro Kerosene Garage Shop Heaters - All Pro PK115T Forced Air Kerosene Space Heater Logo

Related Topics:

276 people viewed this question

Ask a Question

Usually answered in minutes!

Top All-Pro Heating & Cooling Experts

Paul Carew

Level 3 Expert

3249 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

T bone 1963

Level 2 Expert

69 Answers

Are you an All-Pro Heating and Cooling Expert? Answer questions, earn points and help others