I can not say I am an expert on remote controls, but if you havent verified that the batteries are good in the remote Id replace them, Ive had the same experience with remote controls in the past and the batteries have always been the problem.

Posted on Dec 10, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Procom heater will not stayon


check the milivolt reading with a tester or replace the powerpile/pilot assembly

Sep 30, 2016 | Procom Heating & Cooling

1 Answer

Wall heater will not stay on.


Clean out pilot sounds like it is too small to heat tc

Sep 30, 2016 | Procom Heating & Cooling

1 Answer

My Quickstat has stopped working completely. not a gfi reset issue, but zero display. there is still power to unit. Im guessing that I need to replace unit.


Raychem QuickStat-TC Installation & Operation Manual

www.manualslib.com > Brands > Raychem Manuals > Thermostat
View and Download Raychem QuickStat-TC installation & operation manual online.QuickStat-TC Thermostat. QuickStat-TC Thermostat pdf manual download.

Raychem - QUICKSTAT-TC, Programmable, Thermostats ...

www.platt.com > ... > Floor Warming > Thermostats > Programmable

$144.29 - ‎In stock
Raychem QUICKSTAT-TC Programmable Thermostat Programmable Thermostat, 120/240V, 16A, GFCI, 4 Programmable Events per Day.Missing: tyco ‎working

Raychem Quickstat Floor Heating Thermostat Installation ...



Dec 26, 2015 | Raychem by Tyco QuickStat-TC Thermostat

2 Answers

How do you clean the carburetors on a 2005 Victory TC?


w a bike that age u need to diasemble the carb then put it in a solvent it delicate work theyr very complex and easy to hurt a part getta clymer manual for the details the stuf sold in stores mite work for minor issues. but thers alotta gimics

Jul 03, 2014 | 2005 Victory Touring Cruiser

1 Answer

Picture does not fill screen


Hello
Go to its user manual page [20]. Set the formats. How to set the format is described ther, which I can't copy and paste to you by this window.

Feb 06, 2012 | Panasonic TC-P50C1 Plasma TV

1 Answer

Brand new heater installed according to manual yet unit shuts off randomly after running - some times in less than a minute, sometimes after a day and a half of running fine. How do you test the...


I doubt if the ThermoCouple (TC) should have failed this soon!
However-- Here is a page I wrote to help others trouble-shoot and replace the TC

One possibility is that the Thermo Couple is beginning to fail'
What is a Thermo Couple? (TC)
The Thermo Couple (TC) is a small Rod-shaped device with a couple wires coming out the bottom.
The TC actually generates a small electrical current from the heat of the Pilot.
This electrical current is sensed by the control board, or the Main Gas Valve.
As long as there is a pilot, it is safe for the Main gas valve to open, and admit the large amount of gas into the heating burner.

Now-- What helps this TC work the best?
It needs to be just at the edge of the pilot flame--- Not too much in the flame, or the resulting poor combustion of the pilot flame, results in soot forming on the TC-- which insulated the TC from sufficient heat.
Obviously the TC has to be clean (of soot) in order to receive enough heat, to generate the needed voltage to tell the valve that it is safe to open.
And age does deteriorate the TC-- some last a few years, but that is about the end of life for most.
Replacing requires getting down where the TC is, and with a screw driver (usually)-- loosening the bracket that holds the TC. Pay attention to where the wires are routed, and any polarity indicated on the old wires, and duplicate on the new one. Duplicate routing, and polarity, and position the new TC at the edge of the pilot flame.
Pilot flame is maintained by pushing some over ride button-- for a minute or two, until when you begin to release the button, you can feel that the voltage generated by the TC is now holding the pilot valve open, instead of your pressure on the 'start' button.

Any further Questions, let us know..

Mack B

Jan 26, 2011 | Heating & Cooling

1 Answer

My heater, modle # cbn30t when I turn the pilot light on and ignite the fire it works for about 30 seconds and then stops, is this common and does anyone know how to fix it?


One possibility is that theThermo Couple is beginning to fail'
What is a Thermo Couple? (TC)
The Thermo Couple (TC) is a small Rod-shaped device with a couplewires coming out the bottom.
The TC actually generates a small electrical current from the heat ofthe Pilot.
This electrical current is sensed by the controlboard, or the Main Gas Valve.
As long as there is a pilot, it is safefor the Main gas valve to open, and admit the large amount of gas into theheating burner.

Now-- What helps this TC work the best?
It needs to be just at the edge of the pilot flame--- Not too muchin the flame, or the resulting poor combustion of the pilot flame, results insoot forming on the TC-- which insulated the TC from sufficient heat.
Obviously the TC has to be clean (of soot) in order to receive enoughheat, to generate the needed voltage to tell the valve that it is safe to open.
And age does deteriorate the TC-- some last a few years, but thatis about the end of life for most.
Replacing requires getting down where the TC is, and with a screwdriver (usually)-- loosening the bracket that holds the TC. Payattention to where the wires are routed, and any polarity indicated on the oldwires, and duplicate on the new one. Duplicate routing, and polarity, andposition the new TC at the edge of the pilot flame.
Pilot flame is maintained by pushing some over ride button-- for aminute or two, until when you begin to release the button, you can feel thatthe voltage generated by the TC is now holding the pilot valve open, instead ofyour pressure on the 'start' button.

Any further Questions, let us know..

Mack B

Jan 20, 2011 | Desa International CBN30T Central Heating...

1 Answer

I have a 37 inc LG LCD TV. While watching it the TV made a loud pop noise and the screen went black. We lost both the screen and sound. Tried it again this morning and after 2 minutes the same thing...


you have blown an internal fuse you might be suprized to learn that ther is someone veryclose to you who might be able to fix it a lot of people who fix tv's work from home bassically you just neeed ot repalce a small circut board inside it

just google and try to find them

take tc back it should sill be under warenty if they refuse you can say t othem this is not fit for its purpose and force them to fix or replace it

Sep 19, 2009 | LG 37LC7D 37 in. LCD HDTV

1 Answer

Tc not work in my pc


Hi Shashi,
please make sure the TC files are extracted in following folders after installation

c:\tc\bin --> all executable files
c:\\tc\include --> all header files with .h extension
c:\tc\lib --> all library files
c:\tc\obj --> all .obj files copy them to c:\tc\bin too

now goto my computer --> c:\tc\bin
copy tc.exe file and right click on desktop and select copy short cut and press enter

Now you can start TC simply doubleclicking this shortcut icon

Please call if having any problem

Zulfikar Ali
ali_zulfikar@yahoo.com
09899780221

Mar 14, 2009 | Microsoft Windows XP Professional With...

2 Answers

Nikon TC-17E II with Nikon 70-200mm f/2.8


You may have a dirty contact on the tc cpu pins. Try cleaning the pins with a clean pencil eraser or some methanol. You could also have a loose connection between the tc and the lens or body. Try applying a rotational force in both directions...see if you notice any change in behavior. If you have a local shop, see if you can try another copy on your lens.
The 17e may have slow-ish performance in low light, but it should still be usable. If neither of these issues is apparent then it may need to be exchanged or serviced.

Jan 10, 2008 | Nikon TC-17E II for AF-S, AF-I 1.7x Lens...

Not finding what you are looking for?
DISH Network 135899 Remote Control Logo

Related Topics:

44 people viewed this question

Ask a Question

Usually answered in minutes!

Top DISH Network Televison & Video Experts

Steve Allison
Steve Allison

Level 3 Expert

5569 Answers

Jaime Hernandez

Level 3 Expert

2337 Answers

matt martin
matt martin

Level 3 Expert

1244 Answers

Are you a DISH Network Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...