1 Answer

Motel style heat and air

Heating element comes on in off position, but no fan, fan runs in on position not enoufg heat, you might say luke warm air

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.


    An expert who has answered 20 questions.


    An expert that hasĀ over 10 points.


    An expert whose answer gotĀ voted for 2 times.

  • Contributor
  • 26 Answers
Re: motel style heat and air

Meaning not function of heating,pls apply this the following 1) Possible loose connection to reversing valve pls check this wiring connection.
2) Pls check the sensor to thermostat if this a loose connection.
3) Check the Compressor if this not function or loose compression.( Function but not heating )
4) Check if have a Leakage.

Pls go to the nearest repair shop if not solve,

Thanks & best regards,


Posted on Jan 19, 2008

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

Amana ptac during heat mode will blow hot air , then blow cold , but will cycle back to heat eventually is this Normal?

if the fan switch is in the Run position and not the auto position you are getting cool are when the heat element is not on. this is kind of like a way to circulate the air. look for an auto setting it then should only come on when needed. Keep in mind it is normal for the fan to start blowing before the heating element is warmed up, this prevents it from over heating, or coming on when the fan is not working

Nov 26, 2014 | Air Conditioners

1 Answer

Luke warm air coming out of vents even when set to 90 blower fine filter new

some of your sequencers, heating elements, or fusible links are bad.

Jan 10, 2014 | Goodman Air Conditioners

1 Answer

I have a whirlpool wall heat/ac unit, model ACE184XL0. All of a sudden, the heat quit working. Fan still blows, and AC still seems to work, although I can't tell if it's just pulling in cold outside air...

Dear it is a thermostat system. You can simply check it by setting temp at 30 then check either warm air is coming or cool air. at this time warm air should come. If warm air is not coming means there is a fault is realy in your pcb. It can be simply remove no need to worry.

Oct 14, 2013 | Whirlpool ACE244XS Air Conditioner

2 Answers

My Dehumidifier has stopped dehumidifying! The fan works and everything else but it no longer collects water. Its is a DESICCANT variant. The air coming out of the vent also used to be warm and this is no...


There are many reasons why a dehumidifier will not work or collect water.

Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier

Dehumidifier is running but no water is in bucket


Dec 12, 2010 | Air Conditioners

1 Answer

Heater not working. have power going to heating element. I,m guessing there's a heater inside of the roof air conditioner because it has a heat or cool on control panel. I belive the number of unit is QC...

It may be capable of running heat element, but may not have been installed. Remove ceiling cover and you should see an element sometimes shaped similar to a light bulb, or maybe just a straight rod style, but it should be fairly obvious and be sticking out right where the air would blow into your rv, on discharge side of AC unit. Some of them weren't very powerful, so don't expect too much from it, as quite often you only feel slightly warmer air from discharge when they are on. It should have a plug running directly to control box, and be plugged in there. If it is there, turn it on, and see if you feel it getting warm by touch, carefully! If not getting warm/hot to touch, then either control box, faulty, or element is faulty. Checking voltage at that connector with multimeter on AC voltage when it is in the on position should tell you.

Apr 12, 2010 | Dometic Rooftop RV Air Conditioner

1 Answer

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is...

You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ

Jul 21, 2009 | Air Conditioners

1 Answer

Heating Element on my A/C not getting hot

It definitly did not open the element the 24vac isn't enough. I would go back over the wiring.When your t- stat calls for heat you want it to energize both sequencers. the easist way to assure this is to connect the whiet and purple two gether at the a/h.

Mar 14, 2009 | Goodman CLQ36AR49 Air Conditioner

2 Answers

Ruud UBHC-21J18SFA blowing only "luke warm" air at best

That's crazy, we're having the same problem.  Turns out there was a wattage restrictor in the furnace that was switching off 3 of the 5 heating elements in an attempt to save energy.  Basically, the restrictor was sensing that the incoming air was warm, so only 2 of the 5 coils should be needed to heat the air.  Well that wasn't enough and we just sat with the furnace running all day long struggling to reach the 70 degree setpoint. 
This is something a technician can diagnose in a few minutes, but not the sort of thing a DIY'er should really handle.

Dec 22, 2008 | Ruud UBHC Air Conditioner

1 Answer

Inside fan dont run with thermostat in automatic position

some brands use relays and some use sequencers to run the fan in auto

Nov 12, 2008 | Air Conditioners

Not finding what you are looking for?
GE Zoneline AZ55H07D Air Conditioner Logo

Related Topics:

500 people viewed this question

Ask a Question

Usually answered in minutes!

Top GE Air Conditioners Experts


Level 2 Expert

373 Answers

Lawrence Oravetz

Level 3 Expert

7053 Answers


Level 3 Expert

347 Answers

Are you a GE Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides