The fridge gets its cold air from the freezer through a vent(damper)
between the freezer and fridge.The fan in the freezer blows air through it.
Make sure this fan is running. You may have to hold the door switch in for it
to run. There is a flap you adjust with
the fridge temp. control. Make sure it's opening and closing when you adjust
the fridge temp.
The problem could be the electronic control if
you have one or the mechanical linkages.
Make sure the air is flowing in at the top vent and back out at the bottom vent. If it's not flowing, the cold air from the bottom of the freezer will flow back into the crisper area.