New lg air conditioner stops at c5 what does mean? pls help

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 244 Answers

Call an LG Support Representative at (800) 243-0000.

Hope this helps,

jzklipper

Posted on Nov 17, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

LG Air conditioning unit has an error code C5 what does this mean?


You have to try resetting the system. First turn the breaker off for the condenser and wait about 20 seconds. After you turn it back on the system should reset. West Palm Beach Air Conditioning

Jun 12, 2016 | LG LSC121PMA Split System Air Conditioner

1 Answer

Error code 5


is there a battery in the outside part if so try a new one

Feb 01, 2015 | LG Electronics Electronics 10,000 BTU...

1 Answer

Lg airconditioner comes up c5 and stops


Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Jan 21, 2011 | LG Heating & Cooling

1 Answer

Turn on LG aircon inside house. Goes for a short time them c5 comes up on screen and the aircon stops. Compressor has been noted to start and stop


C5- Indoor to put door communication problem.

Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Dec 31, 2010 | LG LSC121PMA Split System Air Conditioner

1 Answer

We recently had a flood go through the house and now when we turn the air conditioner on it displays c5 what does this mean?


C5 Indoor malfunction of gas pipe thermistor. Check amps of your unit .If very less than specified, it's gas leak. If only little difference and having freezing blow, it's coil and blower wheel dust blocked. Service the unit completely and run the unit.
If gas leak call repairman to find leak and arrest and then recharge gas.
Hope it's helpful. Thanks,.

Dec 25, 2010 | LG Heating & Cooling

6 Answers

IDEC aircon E5 error what does it mean?


i am air con tech and i face all ready this problem may be it will help u . e5 error is ur air con not have gas becoze of that the low presser switch give error on disply thanks best regard for all. pls let now if its help full

May 27, 2010 | LG LSC183VMA Split System Air Conditioner

1 Answer

I have a art col air conditioner and it has come up c5 can you tell me what this means thanks


C5 = COMMUNICATION BETWEEN THE INDOOR P.C. AND THE OUTDOOR P.C. MISSED. In other words, there is a bad connection in the indoor outdoor cable, possible cause - rats.

Nov 14, 2009 | Heating & Cooling

1 Answer

Air conditioner shuts off


C5
Communication Error

• Wrong or missing wiring between indoor and outdoor unit cable

• Defect of communication components in indoor pcb assembly

• Defect of communication components in outdoor pcb assembly

• Defect of power supply components in outdoor pcb assembly

• No ground connection in air conditioner unit

(affected by noise in power source)

Jun 30, 2009 | LG Heating & Cooling

3 Answers

Ch 5 error code


ch5 error code, means that there is a
communication error (serial comunication) between the outdoor and the indoor unit.
Only for LG-airconditioners.

Jan 02, 2009 | LG Art Cool LA121HNP Split System Air...

Not finding what you are looking for?
LG Electronic Window Air Conditioner Logo

Related Topics:

285 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Tim Whalen

Level 3 Expert

3072 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...