CH61 - CONDENSER PIPE HIGH PRESSURE

Posted on Nov 18, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How can resolved PJ error in daikin vrv 2


PJ is an error that has to do with the outdoor unit not matching the indoor unit. This means the outdoor board thinks it's a 2 ton unit and the indoor thinks it's a 1 ton unit. (Just throwing those numbers in)...but, the indoor is not matching the outdoor. You need to read the manual and go through the setup process.

Jul 30, 2017 | Heating & Cooling

1 Answer

Error communication btw indoor-outdoor units


The thermostat is the only communication between indoor and outdoor units.

Nov 30, 2013 | Fujitsu 24C1 Air Conditioner

1 Answer

Code u 4 - Daikin model Rxymq48mvju


U4 Is a communication error between indoor and outdoor units.
usually means one of the PC boards is faulty. If unit has been freshly installed check wiring between indoor and outdoor 1,2,3 are the same colours on both boards.

May 04, 2013 | Daikin RXYMQ48MVJU, VRV-S Air Cooled Eight...

1 Answer

My air conditioner has just stopped working with error code CH61 what does this mean?


Not enough air being drawn over the outside condenser unit. This could be for a number of reasons. The unit may be covered, restricted, or blocked. The condensor fan may be inoperable on the unit. Without a model number I would first check the outdoor fan for proper operation, and contactor and run capacitor. It sounds as though the compressor is coming on and going into thermal overload.

Feb 13, 2011 | LG Heating & Cooling

2 Answers

What does error code p8 mean


P8 means Abnormality in outdoor unit.
Check:
1) Wrong wiring of indoor/outdoor
connecting wire
2) Reversed phase
3) Protection device is working
4) Damaged outdoor coil thermistor

Solution:
1) Check the indoor/outdoor connecting wire.
2) Change the connection of electric wiring.
3) Check the protection device.
4) Measure the resistance of the outdoor coil thermistor.
If the resistance is normal, replace the
outdoor controller board

Hope, helpful.

Feb 03, 2011 | Mitsubishi Heating & Cooling

1 Answer

What is the meaning of fault code. error 02. abnormal on my hitachi remote control for cooling unit rpc 5aq5-p


Indoor/outdoor safety device activated. If your unit stops within 5 seconds, indoor coil sensor defective or short of gas/leak. If your indoor works and but out door unit works for just 5minutes and stops means outdoor coil sensor defective or short of gas or leak. find by amps. If less amps than mentioned, is gas leak/short of gas.

Jan 27, 2011 | Heating & Cooling

3 Answers

Ch 5 error code


ch5 error code, means that there is a
communication error (serial comunication) between the outdoor and the indoor unit.
Only for LG-airconditioners.

Jan 02, 2009 | LG Art Cool LA121HNP Split System Air...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

464 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2557 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...