you NRV (none return valve) will be stuck open, so when there is no pressure in the tanks it starts up straight away but when the pressure is present it wont start because air pressure will be keeping the valves closed known as 'starting on load' strip it and clean it make sure there is no pressure in tank.failling that the bleed valve pressure switch is blocked