Hi , I have a Electronic pilot lighting system on my RUUD package unit. The pilot light flame keeps blowing out or is not working properly. I removed the panel to look and see what was wrong. I could not see any faults. The sparker worked just fine, the gas line tubing was fine no blockages( took it off to inspect it) every thing looked good. Worked fine for the last couple of weeks and now it will not ignite the pilot light to light the rest of the propane gas to heat the house. I tested the flame sensor using a mach it worked fine the sensor stopped the sparker and when I removed the mach the sparker started again. Gas value on the module works manually when you push in the switch, all fans work. I am at my wits end not sure what else to try. Any help would be welcomed. James Clements
Sounds like you have checked most things. A pilot will go out if it is dirty, if the gas valve is not holding or if the senser is dirty or bad. Remove the pilot and clean out the small orifice inside. Check all electrical connections, clean the sensor, and make sure the gas valve holds 24 volts on the PV side.
I am installing a used heat pump into my exsisting gas furnace. All have left to do before charging...
(More)
I am installing a used heat pump into my exsisting gas furnace. All have left to do before charging is wire up the low voltage for the heat pump. I can't seem to find out where the wires go from the heat pump. It has 4 wires: Brown
I have a similar problem. It gets up to 78 degrees in the house and the ac unit is set to 65. It...
(More)
I have a similar problem. It gets up to 78 degrees in the house and the ac unit is set to 65. It sounds like it is on all day and my electric bill is rediculous. I have replaced the filter, but have read things about cleaning out the outside unit. Does anyone think that this will help? If so, how do you go about doing it? My duplex management wants to charge me money to send someone over here to look at it...
Hello.. slight problem. Rudd silouette II a/c gas furnace. Fan runs on low speed, and will not shut...
(More)
Hello.. slight problem. Rudd silouette II a/c gas furnace. Fan runs on low speed, and will not shut off. a/c comes on, and get cold, but blows on low. seem like the switch is switched to on, instead of auto.. CVould this be control board? Thanks
I have a ruud ac unit running heat for the second time this winter and now not heating. blowing cool...
(More)
I have a ruud ac unit running heat for the second time this winter and now not heating. blowing cool air