During printing, the main thermistor detects less than 120°C/248°F for 1 sec or more continuously. Main cause: The fixing film unit is faulty (main thermistor fault, thermal fuse blow, fix- ing heater fault). Or the power supply PCB is faulty. Or the DC controller PCB is faulty. Action1. Malfunction Turn off the power; wait for 10 min, and turn on the power. Is the problem corrected? YES:End. 2.Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO:Correct the wiring. 3.Fixing film unit Try replacing the fixing film unit. Is the problem corrected? YES:End. 4.Power supply PCB, DC controller PCB Try replacing the power supply PCB. Is the problem corrected? YES:End. NO:Replace the DC controller PCB