Grills and Smokers
Problem for Grills and Smokers
Generic problem for all Grills and Smokers

Fan works compressor doesn't overload pro...




By rcsuder on Nov 07, 2009

" "
fan works compressor doesn't overload protector keeps clicking 3 pins on compressor all tested short on rx1 tested no grd

Solution #1

posted on Nov 07, 2009
Not Rated)

AZBen

Rank: Guru 
Rating: 98%, 12 votes
Test or replace the run capacitor first. Then add a hard-start capacitor based on the motor size/hp. When checking pins on compressor remove all wires and test to chassis ground since this should be open circuit. Resistance between pins should be in the range of normal start and run windings, not less than 20 ohms on the start windings.
Was this helpful?
Yes
No

Popular Solutions for Grills and Smokers


Questions and Unsolved Problems for Grills and Smokers


Answer
where can i get a vielux large grill thermometer

Answer
Have full tank, but grill won't get above 250 degrees. I turn on one burner and it looks fine. I... (More)

Answer
our rotating grill has quit rotating--its about 2 years old but we use it a lot --it has multiple... (More)

Answer
I am missing a regulator for a Solaire Infrared Grilling Sys model IR17A stainless steel 304


Didn't find what you were looking for?

Describe your Grills and Smokers problem:

Select a Category:







Ask our Experts

 

Solve Your Problem Now!
Chat Live with an Expert
Chat Now
Top Grill and Smoker Experts



Top Range & Oven Repairmen
in , MD
(423) 303-3784
Oven and Range parts delivered overnight...
 Appliance Parts Pros.com

(410) 609-0006
A Leader In Kitchen Equipment Sales,...
Allegro Restaurant Repair


       
Solve Your Problem Now!
Chat Live with an Expert
Chat Now

Insert Link
Insert Image
Insert You-Tube clip
Insert List
Insert List
Spell Check

What is this?



Select