Rheem Tankless waterheater modek rtg-74pvn installed 2 yrs ago, unit shuts off wo warning, error codes displayed c7 76. I turn of unit and restart and it runs ok for a while then shuts off for no real reason. Only other appliance running would be the furnace, this usually happens every fall
Contact Rheem; the Burner control unit has lost comm with the remote...the part is warranteed for up to five years.
Comments:
Nov 11, 2009
- Remove power source from the unit. If remote control is installed; remove cover and lift the control wires on the terminal...can be accomplished from either end.
Restore power and see if unit functions normally.
Contact Paloma/Rheem customer (800-432-8373) support and notify them IF you are getting a code "76" error. Rheem has recently extended the warranty on the "Burner Control Assm."; which is your problem. The C4-C8 portion of the error code, is where the unit stops the ignition process...burner fails to light, or gives you intermittent hot water. In either case, contact customer support.
If this helps, please indicate so. Mike//jzklipper
Was this helpful?
Yes
No
1 person thought this was helpful
Popular Solutions for Rheem RTG-74PVN-2 Natural Gas
Our Rinai makes a loud noise when heating water. It seems to be related to how much and how hot the...
(More)
Our Rinai makes a loud noise when heating water. It seems to be related to how much and how hot the water demand. It sounds a bit like a small engine under a load
i have a 241 system boiler only doing the heating, it fires up on full for about 30 seconds then...
(More)
i have a 241 system boiler only doing the heating, it fires up on full for about 30 seconds then slows down it plods on for about a 60 seconds then turns off it will then switch on and repeat the above the radiators never get above aired,i have recently fitted a new pump ,any ideas ?
I have a Johnson & starley 25-30 mod airflow 2.It fires up for 20 sec then just gos back to...
(More)
I have a Johnson & starley 25-30 mod airflow 2.It fires up for 20 sec then just gos back to pilot. Ive changed the limit stat, fan, and room thermostat, as anyone got anymore pointers for me please. thanks
Code C2 and 11 comes on when hot water is turned on...have to turn off and on multiple time before...
(More)
Code C2 and 11 comes on when hot water is turned on...have to turn off and on multiple time before the unit will start and run ... very Frustrating... especially in morning. This unit was bought and instlled in Novermner of 2008...
I keep getting an error of C2 11 on my Remote Thermostat for the water heater. All of my gas valves...
(More)
I keep getting an error of C2 11 on my Remote Thermostat for the water heater. All of my gas valves are fully open. The water heater runs for a few seconds then kicks off and the error code comes up