I have a pentair minmax nt, natural gas heater. I am getting the E04 message. I know its a fan failure but I hear the fan fine. When I start it, and look at all the LED's in the back, all are lit up except the one labeled 'PV' under the light it says 'LED 13'. It does its three tries then the Fan LED turns off and the TFUSE and HiTemp LED stay on. Then brings up the E04. I know the TFUSE is fine because I just replaced it. What might be the problem?
This problem is most likely caused by a damaged vac tube or bad vac switch. Check those first. The hose/tube may have been damaged, especially if you have any mice running around. It's most likely the vacuum tube, the switch is not as likely to fail but it's wise to make sure both are serviceable.
I have a 250K mimimx nt heater that has been inactive since last spring. I just tried turning it on...
(More)
I have a 250K mimimx nt heater that has been inactive since last spring. I just tried turning it on and fan starts and then heater clicks on for a few seconds and then shuts off. This happens a few more times then the heater shuts off and displays the e04 error code. Any ideas on the problem
Heater does not heat, and fan does not come on. Only light that glows green on heater is the POWER...
(More)
Heater does not heat, and fan does not come on. Only light that glows green on heater is the POWER button. Thank you.
Mini Max NT, Blower seems to work fine but unit will not light and service light is on, any ideas?...
(More)
Mini Max NT, Blower seems to work fine but unit will not light and service light is on, any ideas? Bill
the pilot lights fine but the unit will not alway fire up. after some playing with the unit it...
(More)