I removed the wires from the old thermostat before I realized that I needed to label them so that they could be placed in the proper place on the new thermostat.
Heating, red wire to R terminal and white wire to W terminal. Fan, green wire to G terminal. A/C, yellow wire to Y terminal, there may be a jumper from R1 to R2 terminals. If you have a blue wire it should go to C terminal.
replacing my intermittent pilot module (S86H1006) with the universal S8610U. my original module has...
(More)
replacing my intermittent pilot module (S86H1006) with the universal S8610U. my original module has 2 terminals labeled 24V1 and 24V2. Where do I connect the wires on the new module?
the heat will not come on. Checked the fuse and replaced batteries - the air and fan work. I have...
(More)
the heat will not come on. Checked the fuse and replaced batteries - the air and fan work. I have white-rodgers 9910S - don't know if this has any bearing but we just returned from 10 days away.